EMF-819 Electromagnetic Pollution

The document describes an EMF-819 3-axis radio frequency electromagnetic field meter that measures electromagnetic field strength from 100 MHz to 3 GHz. It has features such as a 3-axis probe, alarm settings, data hold, and peak hold. The meter is intended for general use in monitoring electromagnetic fields from devices like cell phones, medical equipment, and industrial sources.

Uploaded by

Lenin Suca
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
141 views2 pages

EMF-819 Electromagnetic Pollution

The document describes an EMF-819 3-axis radio frequency electromagnetic field meter that measures electromagnetic field strength from 100 MHz to 3 GHz. It has features such as a 3-axis probe, alarm settings, data hold, and peak hold. The meter is intended for general use in monitoring electromagnetic fields from devices like cell phones, medical equipment, and industrial sources.

Uploaded by

Lenin Suca
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

100 MHz to 3 GHz, general purpose

3 AXIS RADIO FREQUENCY


ELECTROMAGNETIC
FIELD METER
Model : EMF-819

LUTRON ELECTRONIC

ISO-9001, CE, IEC1010

100 MHz to 3 GHz, general purpose


Radio Frequency Radiation Meters Electromagnetic Field strength measurement

3 AXIS RF ELECTROMAGNETIC FIELD METER


FEATURES
*
*
*
*
*
*
*
*
*
*
*
*
*
*

Model : EMF-819

3 Axis probe.
Radio frequency electromagnetic field tester.
Wide measuring frequency ranges, 100 MHz to 3 GHz.
EMF-819 is used for broadband devices of monitoring
the wide range radio frequency electromagnetic field
value.
For precision measurement consideration, the meter
is included one probe :
EP-05H ( High frequency Probe, 100 MHz to 3 GHz )
Unit : V/m, W/m^2, mW/cm^2.
Alarm setting function can warn the user if the
measuring antenna is too near the strong radiation
sources, the buzzer will sound to remind the user.
Peak hold function to latch peak value.
Data hold function to lock the current reading.
RS232 computer interface.
Hard carrying case is included.
Large size LCD with contrast adjustment, which can fit
best viewing angle.
Microcomputer circuit provides special function & offers
high accuracy.
Powered by 006P DC 9V battery or DC 9V adapter.

APPLICATIONS

GENERAL SPECIFICATIONS

Circuit

Display
Measurement
Unit
Accuracy
Probe structure
Probe Input
Impedance
Sensor
Structure
Data Hold
REC Function
Power off

Peak Hold
Alarm Setting
Sampling Time
Low Battery
Indicator
Data Output
Operating
Temperature
Operating
Humidity

SAFETY INSTRUCTIONS

Power Supply

Danger
Power Current
Weight
Dimension

General public
Frequency range
10 to 400 MHz
400 to 2000 MHz
2 to 300 GHz

e-field strength (V/m)


28
1.375 x f^1/2
61

Occupational
Frequency range
10 to 400 MHz
400 to 2000 MHz
2 to 300 GHz

e-field strength (V/m)


61
3 x f^1/2
137

* Appearance and specifications listed in this brochure are subject to change without notice.

Semiconductor
Freeze the display reading.
Record Maximum & Minimum value.
Auto shut off saves battery life or
manual off by push button.

To latch the peak measurement value.


Buzzer will sound when display over the
setting value.
Approx. 1 second.
When display show Low battery
Indicator, it should change the batteries.
RS 232 PC serial interface.
0 to 50 .
Less than 80 %RH.
DC 9 V battery ( 006P )

* Heavy duty or Alkaline type.

DC 9V adapter input.
Approx. DC 5.95 mA
425 g/ 0.94 LB.

Main instrument :

200.0 x 76.2 x 36.8 mm

Probe :
Accessories
Included

Attention
* Claims by some scientists that long term exposure to
electromagnetic field may be the cause of childhood
leukemia & other forms of cancer.
* Complete answers to any of these and related
questions are not currently available. At the present
time the most common practice is to avoid excess
exposure over long period of time.
* Complete answers to any of these and related
" Prudent Avoidance " as stated by the Environmental
Protection Agency(EPA) USA is recommended.
* According to ICNIRP of reference levels to time-varying
electromagnetic fields,The E-field strength levels are:

< 2 dB.
3 Axis.
50 OHM

* Can default auto power off or manual


power off.
* When default auto power off ,
power will off automatically after
10 min. if no button be pressed.

This meter is specially developed for measuring or monitoring


electromagnetic field, for example:
cell-phone station, hospital equipment, radar , micro-wave
oven, radiation work, TV antenna , Radio station , welding
equipment , baking- equipment, television , computer , factory,
laboratory , and other environment...etc.

* For worker's safety, be aware that persons with


electromagnetic implant ( e.g. cardiac-pacemarker ) are
subject to especial danger in some case.
* Particular to observe the local safety regulations of the
operator of the equipment.
* Before using the device, it need to know that how to
setting " alarm-limit " value.

Custom one-chip of microprocessor LSI


circuit.
LCD size : 58 mm x 34 mm.
V/m, mW/cm^2, W/m^2.

Optional
Accessories

70 mm ( diameter) x 240 mm ( length)


Instruction manual.............................. 1 PC
EP-05H Probe......................................1 PC
Memory card for EP-05H......................1 PC
Hard carrying case...............................1 PC
DC 9V power adapter...........................1 PC
RS232 cable, UPCB-02.
USB cable, USB-01.
Data Acquisition software,SW-U801-WIN.

ELECTRICAL SPECIFICATIONS ( 23 5 )
Strength Range
0 to 200.00 V/m
0 to 99.999 W/m^2

Resolution
0.01 V/m
0.001 W/m^2
0 to 9.9999 mW/cm^2 0.0001 mW/cm^2

Effective Value
> 1 V/m
> 0.03 W/m^2
> 0.0003 mW/cm^2

Frequency Range
50 MHz to 2.5 GHz

Test Point
60 V/m

Accuracy
< 2 dB

Remark:
* Measurement under other frequency range
( below 100 MHz and over 2.5 GHz ), the reading
value just for reference only.
* For precision measurement consideration, it
should select the " Frequency Team point "
near the frequency value of measuring object.

0710-EMF819