100% found this document useful (2 votes)
2K views4 pages

Pile Cap For 4 Piles

This document provides design details for a pilecap and column foundation, including: - Dimensions and material properties of the pilecap and column - Loads applied to the column - Calculations of internal forces and moments in the pilecap - Reinforcement requirements for the pilecap in the x and z directions - Checks for shear capacity and side face reinforcement requirements The document confirms the pilecap design using 4 piles supporting a single column meets design requirements for strength and serviceability.

Uploaded by

hemantkle2u
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
2K views4 pages

Pile Cap For 4 Piles

This document provides design details for a pilecap and column foundation, including: - Dimensions and material properties of the pilecap and column - Loads applied to the column - Calculations of internal forces and moments in the pilecap - Reinforcement requirements for the pilecap in the x and z directions - Checks for shear capacity and side face reinforcement requirements The document confirms the pilecap design using 4 piles supporting a single column meets design requirements for strength and serviceability.

Uploaded by

hemantkle2u
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

THICKNESS OF PILECAP (T) = 0.

70 m
CLEAR COVER = 0.075 m
WIDTH OF PILECAP (B) = 3.75 m
LENGTH OF PILECAP (L) = 3.75 m
WIDTH OF COLUMN (b) = 0.45 m
DEPTH OF COLUMN (d) = 0.45 m
f
ck
FOR PILECAP = 25 Mpa
f
y
FOR PILECAP = 415 Mpa
THICKNESS OF SOIL LAYER ABOVE PILECAP = 0.60 m
UNIT WEIGHT OF SOIL ABOVE PILECAP = 18.00 kN/m
3
CLEAR CANTILEVER FROM PILE = 0.15 m
DIAMETER OF PILES = 0.40 m
COLUMN F
y
(kN) F
x
(kN) F
z
(kN) M
x
(kN.m) M
z
(kN.m)
82 83.50 46.50 46.50 690.00 690.00
C
Y
0.7 X
Z
3.75
1 2
0.45
3.75
r
zi
3 4
r
xi
COLUMN C
MOMENT DUE TO SHEAR AT PILECAP BASE (M
X
') 32.55 kN.m
MOMENT DUE TO SHEAR AT PILECAP BASE (M
Z
') -32.55 kN.m
TOTAL BENDING MOMENT (M
X
) 722.55 kN.m
TOTAL BENDING MOMENT (M
Z
) 657.45 kN.m
TOTAL VERTICAL UNFACTORED FORCE 481.47 kN
UNFACTORED REACTIONS AT COLUMN BASE
PILECAP DESIGN FOR 4 PILES WITH A SINGLE COLUMN
0.45 C
PILE NO. r
xi
(m) r
xi
2
r
zi
(m) r
zi
2
1 1.000 1.00 1.000 1.00
2 1.000 1.00 1.000 1.00
3 1.000 1.00 1.000 1.00
4 1.000 1.00 1.000 1.00
r
xi
2
= 4.00 r
zi
2
= 4.00
137 kN 465 kN
X
0.45 2.00 1.6
- 225 kN 104 kN
0.575
Z
0.15
0.45
0.575
2.00
1.6
- 88 kN 569 kN
MAXIMUM ULTIMATE BENDING MOMENT (M
UX
) = 519 kN.m
MAXIMUM ULTIMATE BENDING MOMENT (M
UZ
) = 491 kN.m
EFFECTIVE DEPTH ALONG-X DIRECTION = 0.619 m
EFFECTIVE DEPTH ALONG-Z DIRECTION = 0.607 m
X-DIRECTION
A
st
REQUIRED = 2234 mm
2
MIN. A
st
REQUIRED = 2786 mm
2
DIA. OF MAIN BARS = 12 mm
DIA. OF DISTRIBUTION BARS = 12 mm
REQUIRED SPACING OF MAIN BARS = 152 mm (MN. STEEL)
PROVIDED SPACING OF MAIN BARS = 150 mm
REQUIRED SPACING OF DISTRIBUTION BARS = 152 mm
PROVIDED SPACING OF DIST. BARS = 150 mm
Z-DIRECTION
A
st
REQUIRED = 2413 mm
2
MIN. A
st
REQUIRED = 2732 mm
2
DIA. OF MAIN BARS = 12 mm
DIA. OF DISTRIBUTION BARS = 12 mm
REQUIRED SPACING OF MAIN BARS = 155 mm (MN. STEEL)
PROVIDED SPACING OF MAIN BARS = 150 mm
REQUIRED SPACING OF DISTRIBUTION BARS = 155 mm
PROVIDED SPACING OF DIST. BARS = 150 mm
-225
104
FINAL FORCES
IN PILE (kN)
137
465
-121 kN
602 kN
0.15
SECTION ALONG X
SECTION ALONG Z
4
2 1
3
ONE-WAY SHEAR
ALONG-X
-117 0.619 0.619 760
-132 854
0.4 1.6 0.4
MAXIMUM ULTIMATE SHEAR AT CRITICAL SECTION (V
U
) = 760 kN
ULTIMATE SHEAR STRESS (
u
) = 0.33 N/mm
2
pt OF STEEL PROVIDED = 0.12 %
SHEAR STRESS IN CONCRETE (
C
) = 0.29 N/mm
2
SHEAR STRESS RESISTED BY DIST. STEEL (
us
) = 0.15 N/mm
2
TOTAL SHEAR STRESS RESISTED BY SECTION = 0.44 N/mm
2
DESIGN FOR SHEAR IS NOT REQUIRED IN X-DIRECTION.
ALONG-Z
-166 0.607 0.607 831
-181 903
0.4 1.6 0.4
MAXIMUM ULTIMATE SHEAR AT CRITICAL SECTION (V
U
) = 831 kN
ULTIMATE SHEAR STRESS (
u
) = 0.36 N/mm
2
pt OF STEEL PROVIDED = 0.12 %
SHEAR STRESS IN CONCRETE (
C
) = 0.29 N/mm
2
SHEAR STRESS RESISTED BY DIST. STEEL (
us
) = 0.15 N/mm
2
TOTAL SHEAR STRESS RESISTED BY SECTION = 0.44 N/mm
2
DESIGN FOR SHEAR IS NOT REQUIRED IN Z-DIRECTION.
SHEAR FORCE DISTRIBUTION
SHEAR FORCE DISTRIBUTION
CHECK FOR SHEAR
TWO-WAY SHEAR
ALONG-X
32 0.310 0.310 691
-132 854
0.4 1.6 0.4
MAXIMUM ULTIMATE SHEAR AT CRITICAL SECTION (V
U
) = 691 kN
ULTIMATE SHEAR STRESS (
u
) = 0.26 N/mm
2
SHEAR STRESS IN CONCRETE (
C
) = 1.25 N/mm
2
k
s
.
c
= 1.25 N/mm
2
SECTION IS OK IN SHEAR.
ALONG-Z
3 0.304 0.304 719
-181 903
0.4 1.6 0.4
MAXIMUM ULTIMATE SHEAR AT CRITICAL SECTION (V
U
) = 719 kN
ULTIMATE SHEAR STRESS (
u
) = 0.28 N/mm
2
SHEAR STRESS IN CONCRETE (
C
) = 1.25 N/mm
2
k
s
.
c
= 1.25 N/mm
2
SECTION IS OK IN SHEAR.
SIDE FACE REINFORCEMENT
AREA REQUIRED FOR SIDE FACE REINFORCEMENT = 656 mm
2
DIAMETER OF SIDE FACE REINFORCEMENT = 12 mm
SPACING REQUIRED = 105 mm
SPACING PROVIDED = 100 mm
SHEAR FORCE DISTRIBUTION
SHEAR FORCE DISTRIBUTION