This document contains a diagnostic code list for the Caterpillar Monitoring System with a Module ID number of 030. It includes diagnostic codes and failure mode indicators for various sensors that monitor things like fuel level, engine oil pressure, coolant temperature, and more. It notes that not all machines will have all the diagnostic codes or failure mode indicators listed. The table provides diagnostic trouble codes and descriptions to help technicians identify issues.
Download as DOCX, PDF, TXT or read online on Scribd
100%(1)100% found this document useful (1 vote)
2K views
Caterpillar Monitoring System
This document contains a diagnostic code list for the Caterpillar Monitoring System with a Module ID number of 030. It includes diagnostic codes and failure mode indicators for various sensors that monitor things like fuel level, engine oil pressure, coolant temperature, and more. It notes that not all machines will have all the diagnostic codes or failure mode indicators listed. The table provides diagnostic trouble codes and descriptions to help technicians identify issues.
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3
Caterpillar Monitoring System / Diagnostic Code List
Diagnostic Code List
Table 1 Diagnostic Codes For The Caterpillar Monitoring System (MID No. 030) (1)
CID/FMI Description CID 0096 - Level Sender (Fuel): FMI 03 Signal voltage above normal or short to +battery FMI 04 Voltage below normal or short to ground FMI 08 Signal is abnormal CID 0096 - Level Sensor (Fuel): FMI 08 Signal is abnormal CID 0100 - Pressure Sensor (Engine Oil): FMI 08 Signal is abnormal CID 0110 - Temperature Sensor (Engine Coolant): FMI 04 Voltage below normal or short to ground FMI 08 Signal is abnormal CID 0177 - Temperature Sensor (Transmission Oil): FMI 04 Voltage below normal or short to ground FMI 08 Signal is abnormal CID 0248 - Data Link: FMI 02 Data erratic, intermittent, or incorrect CID 0263 - Sensor Power Supply: FMI 03 Signal voltage above normal or short to +battery FMI 04 Voltage below normal or short to ground CID 0271 - Alarm (Action): FMI 03 Signal voltage above normal or short to +battery FMI 05 Current below normal or open circuit FMI 06 Current above normal or short to ground CID 0324 - Lamp (Action): FMI 03 Signal voltage above normal or short to +battery FMI 05 Current below normal or open circuit FMI 06 Current above normal or short to ground CID 0427 - Temperature Sensor (Front Axle Oil): FMI 08 Signal is abnormal CID 0428 - Temperature Sensor (Rear Axle Oil): FMI 08 Signal is abnormal CID 0600 - Temperature Sender (Hydraulic Oil): FMI 03 Signal voltage above normal or short to +battery FMI 04 Voltage below normal or short to ground FMI 08 Signal is abnormal CID 0600 - Temperature Sensor (Hydraulic Oil): FMI 08 Signal is abnormal CID 0819 - Display Data Link: FMI 02 Data erratic, intermittent, or incorrect FMI 15 Invalid code FMI 31 Invalid code CID 0821 - Display Power Supply: FMI 03 Signal voltage above normal or short to +battery FMI 04 Voltage below normal or short to ground CID 0826 - Temperature Sender (Torque Converter Oil): FMI 03 Signal voltage above normal or short to +battery FMI 04 Voltage below normal or short to ground FMI 08 Signal is abnormal CID 0826 - Temperature Sensor (Torque Converter Oil): FMI 08 Signal is abnormal CID 0830 - Temperature Sensor (Brake Oil): FMI 08 Signal is abnormal CID 1791 - Saw Pressure Sensor: FMI 08 Signal is abnormal ( 1 ) This table pertains only to diagnostic codes with a MID of 030. Note: Every machine may not have all of the diagnostic codes that are listed in the preceding table. Also, every machine may not have all the FMI for a given CID. Note: The preceding table shows the diagnostic codes for the Caterpillar Monitoring System. When the Caterpillar Monitoring System is in the service mode, diagnostic codes from the other electronic control modules are shown on the display area of the Caterpillar Monitoring System. The information from the diagnostic code is transferred from other electronic control modules via the Cat Data Link to the main display module. This diagnostic information is shown when the main display module is in the service mode. The module identifier (MID) indicates the electronic control module that is sending the diagnostic code. The MID for the Caterpillar Monitoring System is "030". This Service Manual is used for diagnostic codes with a MID of "030". The MID of other electronic control modules on a particular machine are listed on the Electrical System Schematic. Troubleshooting information for those diagnostic codes can be found in the service manual for that system. Note: When a sensor diagnostic code is present, the corresponding warning for that sensor is also activated for the operator. For example, if the signal wire for the engine coolant temperature sensor is shorted to the +battery, then the following actions take place: The corresponding diagnostic code is stored in memory. The gauge for the engine coolant temperature is indicating in the warning region. The action lamp is FLASHING. Notice that the second and third above items are the same warning indications that are activated if the engine overheats.