XPIO 2000 (r) data acquisition and control system allows operators to monitor and control downhole gauges and topside instrumentation. System is available in a range of capacities, from 1-well / 4-gauges to 4-wells / 8-gauges. UACU+ extends capacity up to 20-well / 40-gauges for a single unit.

Uploaded by

josueabisay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
750 views2 pages

H06988 - Xpio 2000

XPIO 2000 (r) data acquisition and control system allows operators to monitor and control downhole gauges and topside instrumentation. System is available in a range of capacities, from 1-well / 4-gauges to 4-wells / 8-gauges. UACU+ extends capacity up to 20-well / 40-gauges for a single unit.

Uploaded by

josueabisay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

XPIO 2000

Data Acquisition and Control System


Monitor and Control Downhole Gauges and Topside Instrumentation
COMPLETIONS SOLUTIONS
Intelligent Completions
Digital Infrastructure
H
A
L
3
1
4
2
4
Output from the XPIO 2000

System
Halliburton WellDynamics XPIO 2000

data acquisition and


control system allows operators to monitor and control downhole
gauges and topside instrumentation. Acquiring data at a rate of 0.5
seconds per gauge, the XPIO 2000 system is available in a range of
capacities, from 1-well/4-gauges to 4-wells/8-gauges. A larger
variant within the XPIO 2000 range is the UACU+, which extends
capacity up to 20-wells/40-gauges for a single unit. Te UACU+ is
ftted with a permanent downhole gauge interface card (PDGIC)
module for each downhole channel.
Downhole cable inputs are independent and fully isolated.
Features
Up to four permanent downhole gauge communications
channels (up to 20 for UACU+)
Five channels of 4-20mA analog inputs (12-bit)
Four channels of 4-20mA analog outputs (16-bit)
4Mb of on-board Flash memory plus 2GB of CompactFlash
memory
Modbus RTU protocol support via RS-485 or RS-232 port, or via
TCP/IP port
Modem communications support via the RS-232 port
Two relay contacts
Communications programs that allow full confguration of the
unit
Benets
Control WellDynamics permanent downhole gauges, including
the ROC

family, SmartLog

and surface instruments


Store and display data from WellDynamics permanent
downhole gauges and surface sensors
Interface with external systems, including third-party computers
and distributed control systems
Analog Inputs
Te XPIO 2000 system features fve channels of 4-20mA inputs
(12-bit) that are fully confgurable using the XPIO 2000 PC
program. Users can set the ofset, span, and units of measure, and
then can choose to monitor them on the display or log them into
memory.
Analog Outputs
Te XPIO 2000 system features four channels of 4-20mA outputs
(16-bit). Users can select the pressure, temperature, span and ofset
of a permanent downhole gauge, and the XPIO 2000 system will
drive the translated value onto an output as it is decoded from
downhole.
Memory Logging
Te XPIO 2000 system comes with 4MB of on board Flash memory.
A CompactFlash card extends the memory by 2GB as standard.
Te standard 2GB CompactFlash provides memory capacity to
hold pressure and temperature data from two gauges at one second
updates for more than a year.
Te data is retrieved via an RS-232 port using the supplied PC
program or by File Transfer Protocol (FTP) over the TCP/IP link,
and can easily be imported to other applications such as a
spreadsheet. Data is logged to memory at a maximum rate of once
per second.
Both the standard XPIO and UACU+ are available in NEMA4X
enclosure and 19 rack mount versions. Te 19 rack mount
UACU+ has a capacity of 10-wells/20-gauges.
H
A
L
3
1
4
2
5
www.halliburton.com
2009 Halliburton. All rights reserved. Sales of Halliburton products and services will be in accord solely with the terms and conditions contained in the
contract between Halliburton and the customer that is applicable to the sale. H06988 11/09
COMPLETIONS SOLUTIONS
For more information on any of the details featured here, please email us at
[email protected].
Serial Communications
Te XPIO 2000 system supports Modbus RTU protocol via its
RS-485 or RS-232 port or via its TCP/IP port. Tese interfaces are
fully confgurable in terms of parity, baud rate, etc. As a slave
device, the XPIO 2000 system provides gauge data (i.e., pressure
and temperature) that can be polled, as well as data from any of the
4-20mA inputs. Time and date are also available.
Modem Support
Te XPIO 2000 system supports modem communications via the
RS-232 port. Users may dial into the unit using the supplied PC
program, or use the port to talk to Modbus over a radio modem,
cellular modem, or regular modem.
Pressure-Controlled Relay Contacts
Te XPIO 2000 system comes with two relay contacts (A at
115VAC) which are controlled by sofware. When a selected gauges
pressure rises above, or falls below, a set pressure, the contact is
closed. Tis feature is ideal for alarms and/or pump control.
Web-Installed PCApplication
Te XPIO 2000 system comes with a Web-installed application that
provides for full confguration of the unit, as well as data memory
retrieval, real-time logging of data to the computer hard drive, and
real-time data trending.
Te application communicates with the XPIO 2000 system via a
standard RS-232 port, and runs under Windows

2000/XP/Vista.
Operating Information
110/250Vac or 10-36VDC power input
14W power consumption plus 1W per gauge for XPIO
10W power consumption plus 2W per PDGIC plus 1W per gauge
for UACU+
-10 C to 85 C operation
Gauges Supported
WellDynamics ROC family of permanent downhole gauges
SmartLog cost-efective gauges
EZ-Gauge

permanent pressure gauges


Communication Ports
2 x RS-232
1 x RS-485
10-BASE-T option
Port Usage Options
1 RS-232 dedicated to XPIO PC program
Modbus RTU
Modem support (radio/cell)
TCP/IP via ethernet (optional)
Inputs
Five 4-20mA inputs (12-bit)
One 16-bit A/D (tool current)
Outputs
Four 4-20mA outputs (16-bit)
Two pressure-controlled relays
Memory
4MB on-board Flash memory
2GB CompactFlash memory
Enclosure
NEMA-4 type water resistant
Anodized aluminum
19 rack-mount option
Variants
XPIO 1-well/8-gauges
XPIO-QT+ 4-wells/8-gauges
UACU+ 10 or 20-wells/40-gauges
UACU+ 19 rack 5 or 10-wells/20-gauges

You might also like