Cathodic Protection Calculation of No of Magnesium Anodes Design Data
This document provides calculations to determine the number of magnesium anodes needed to provide cathodic protection for an underground steel tank over a 5-year design life. Given the tank's diameter, height, design life, anode weight, tank radius, anode capacity, and current densities for protecting steel in different materials, the calculations determine that 2.78 or rounded up to 3 magnesium anodes would be needed.
Download as XLS, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
193 views
Cathodic Protection Calculation of No of Magnesium Anodes Design Data
This document provides calculations to determine the number of magnesium anodes needed to provide cathodic protection for an underground steel tank over a 5-year design life. Given the tank's diameter, height, design life, anode weight, tank radius, anode capacity, and current densities for protecting steel in different materials, the calculations determine that 2.78 or rounded up to 3 magnesium anodes would be needed.
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1
CATHODIC PROTECTION
Calculation of No of Magnesium Anodes
Design Data Tank diameter in , 16.22 m Tank height, h 4.264 m Design Life 5 years Weight of Anode, kg 27.3 kg Tank radius, r, 8.11 m Capacity 1230 amp hrs kg^-1 U 0.8 Current Density for protection of steel plate 0.005 I^A Current Density for protection of steel plate in concrete 0.003 Am^-2 No of anodes 2.78 Round off to 3.00
Sexton's Pocket-Book for Boiler-Makers and Steam Users: Comprising a Variety of Useful Information for Employer and Workmen, Government Inspectors, Board of Trade Surveyors, Engineers in Charge of Works and Ships, Foreman of Manufactories, and the General Steam-Using Public