0% found this document useful (0 votes)
193 views

Cathodic Protection Calculation of No of Magnesium Anodes Design Data

This document provides calculations to determine the number of magnesium anodes needed to provide cathodic protection for an underground steel tank over a 5-year design life. Given the tank's diameter, height, design life, anode weight, tank radius, anode capacity, and current densities for protecting steel in different materials, the calculations determine that 2.78 or rounded up to 3 magnesium anodes would be needed.

Uploaded by

Hemantk8731
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
193 views

Cathodic Protection Calculation of No of Magnesium Anodes Design Data

This document provides calculations to determine the number of magnesium anodes needed to provide cathodic protection for an underground steel tank over a 5-year design life. Given the tank's diameter, height, design life, anode weight, tank radius, anode capacity, and current densities for protecting steel in different materials, the calculations determine that 2.78 or rounded up to 3 magnesium anodes would be needed.

Uploaded by

Hemantk8731
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

CATHODIC PROTECTION

Calculation of No of Magnesium Anodes


Design Data
Tank diameter in , 16.22 m
Tank height, h 4.264 m
Design Life 5 years
Weight of Anode, kg 27.3 kg
Tank radius, r, 8.11 m
Capacity 1230 amp hrs kg^-1
U 0.8
Current Density for protection of steel plate 0.005 I^A
Current Density for protection of steel plate in concrete 0.003 Am^-2
No of anodes 2.78
Round off to 3.00

You might also like