Notes
Notes
2.SITE
2241
Excavation
3.STRUCTURE
3155M
Maxraft Floor System
MIN ROAD BOUNDARY SETBACK, 4 METRES
CONTRACTOR SHALL VERIFY ALL
CONDITIONS AND DIMENSIONS AT THE JOB
SITE AND NOTIFY THE ARCHITECT OF ANY
DIMENSIONAL ERRORS, OMISSIONS, OR
DISCREPANCIES BEFORE BEGINNING OR
FABRICATING ANY WORK
+0.00 DATUM (TOK IN LINE WITH
WATER TOBY)
+0.490
2241
1,975
+0.760
+0.610
HOMEOWNER WITHH TAKE NECESSARY
PRECAUTIONS TO REMOVE OR RELOCATE
ITEMS OR VALUE TO BE REUSED AND/OR
SAVED. OR IN ANY DANGER OF BEING
DAMAGED OF BEING OF BEING DAMAGED
DUE TO CONSTRUCTION PROCESS
50500
4,000
+0.675
+0.770
KEY PROPOSED SITE PLAN
Y
SE
U
MO
16700
FFL +0.995
PROPOSED BUILDING FOOTPRINT
6,083
+0.620
154.529m
RIV
RD
PROPOSED DRIVEWAY
+0.785
36.6253m
65.30 m2
PAVED ASHPHALT
2 Car Garage
GARAGE:
LEGAL DESCRIPTION
LOT 7 DP 455692
LOT SIZE: 902 M2
LAND USE :30%
36.63m
59000
Driveway
+0.750
+0.710
1,790
PROPOSED HOUSE FLOOR AREA
(CURRENT LAND COVERAGE: 0 m)
LIVING:
156.21m
COVERED PATIO:
78.19m
TOTAL INTERIOR FLOOR: 192.84m
TOTAL COVERED FLOOR: 271.03m
3155M
3,740
+0.785
+0.640
MIN SETBACK FOR GARAGE (WITH DOOR FACING
THE ROAD), 5.5 METRES FROM ROAD
40 METER BUILDING
SETBACK FOR STATE
HIGHWAY 1
INTERNAL BUILDING SETBACK , 2 METRES MIN
Site Plan
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:200
Drawing Scale: A3
SITE & LEVELS PLAN
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
2.5 METER
BOUNDARY
HEIGHT
N
SI
O
RE
CE
S
47
E
AN
PL
2,000
42
2.5 METER
BOUNDARY
HEIGHT
2.5 METER
BOUNDARY
HEIGHT
PL
AN
E
N
O
I
SS
E
EC
R
NE
A
PL
IO
SS
CE
RE
42
R
EC
ES
SI
O
N
47
PL
AN
E
Notes
2.5 METER
BOUNDARY
HEIGHT
1,790 ( GARAGE)
16,700
North recession plane
1:200
South recession plane
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:200
Drawing Scale: A3
RECESSION PLANES
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
FALL
E
PIL
CK
STO
KEY - SEDIMENT CONROL
Drainage Contol
PROPOSED BUILDING
Drainage Contol
Stabilised Enry / Exit Pad
STABILISED
ENTRY PAD
FALL
Notes
1. All erosion and sediment control structures to be
inspected each working day and maintained in good
working order
2.All ground cover vegetation outside the immediate
building area to be preserved during the building
phase.
3. All erosion and sediment control
measures to be installed prio to
commencement of majo earthworks.
4.Stockpiles of clayey material to be
covered with an impervious sheet
5.Roof water downpipes to be
connected to the permanent
underground stormwater
drainage system as soon as
practical after the roof is laid.
Sediment control
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:200
Drawing Scale: A3
SEDIMENT CONTROL PLAN
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
1,300
300
3,490
300
4,040
300
2,610
7,290
300
1,650
300 600
1,300
300
300
4,000
4,385
5,030
300
6,083
15,540
300
945 1,300
3,300
300
400
17,600
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
300
1,790
1,150
3,740
300
3,630
5,975
300
15,620
300
3,270
1,975
300
300
T
V
300
Drawing Scale: A3
LANDSCAPE PLAN
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
7.SERVICES
7141
Inspection point
7141b
Terminal vent 80mm
80mm dia PVC terminal
through soffit
vent
7141d
Air admittance valve
7431a
Drainage strom water
100mm dia uPVC storm water drain
connceted to street laterals at
boundary with min 1:120 fall
Drainage sewer
100mm dia uPVC sewer drain
connceted to street laterals at
boundary with min 1:120 fall
ACCESSIBLE ISOLATION VALVE
AND SAND FILTER IN
REMOVABLE PANEL ON WALL
IN GARAGE CUPBOARD
BATHROOM EXTRACTOR
VENTING 166.068M MINIMUM
PER HOUR THROUGH SOFFIT
7141b
DP
7141
IP
IP
WATER SUPPLY
TOBY
Shower: Pipe Size DN40 at
1:40 fall
Bath: Pipe Size DN40 at
1:40 fall
DP
DP
GT
WC: Pipe Size DN100 at
1:40 fall
7431a
FOUL WATER
TO EXISTING
LATERALS
7141d
4m
SOAKPIT
4m
SOAKPIT
Sink: Pipe Size DN40 at
1:40 fall
Basin: Pipe Size DN32 at
1:40 fall
7141d
DW: Pipe Size DN40 at
1:40 fall
DW
1m OF SOAK
PIT PER 40m
7141d
WASHING MACHINE: Pipe
Size DN40 at 1:40 fall
OF ROOF
7431b
DW
7141d
7141d
80mm down pipes
DP
7431a
40-50mm grey water pipes
at 1:40 fall
HWC
7431b
GT
GT
TOTAL ROOF AREA = 298.51m
59m OF ROOF AREA PER DOWNPIPE,
5 DOWNPIPES
DP
110mm Foul Water pipes
7141
7141b
IP
DP
IP
IP
IP
Meter Box
KITCHEN EXTRACTOR VENTING
296.164 MINIMUM PER HOUR
THROUGH SOFFIT
BATHROOM EXTRACTOR
VENTING 240.36M PER
HOUR MINIMUM,
THROUGH SOFFIT
T
V
Inspection Point
Terminal Vent
W/C EXTRACTOR FAN VENTING 65.52m
MINIMUM PER HOUR THROUGH ROOF TO
MANUFACTURERS SPECIFICATIONS
9KG GAS BOTTLE IN CUPBOARD
UNDER BENCH VENTED THROUGH
EXTERIOR WALL WITH VERMIN
PROOF MESH, NO ELECTRICAL
SWITCHES OR SOCKETS
Site Services Plan
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:200
Drawing Scale: A3
SERVICES PLAN
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
21,600
190
500
3,400
90
Room Sizes
90
2,520
4,340
4,000
Internal Dimensions
90
90
3,910
2,610
3,945
90
90
3,945
Living
90
90
305
305
190
90
1,080
90
90
300
4,020
11,040
90
1,590
90
90
620
90
3,200
3,090
90
1,600
3,200
90
620
90
3,200
90
620
90
890
2,260
90 940
3,200
Bedroom Two
Walk in Robe
Master Bedroom
90
4,800
1,320
90
3,200
1,400
90 90
90
90
4,020
Dining
Room Sizes
3,090
300
90
Bedroom One
90
Ensuite
Overall Frame
Openings
3,945
Frame Breaks
Structural steelwork
Light steel framed buildings ground
floor
Interior and exteriorground floor
walls to be 90x45mm 0.55mm galv.
c-section steel studs at 450 CRS
90
7,290
Wall Junctions
3411
3421a
3,910
3,270
Openings
Maxraft Floor System
2,610
305
Internal Dimensions
90
Wall Junctions
3155M
4,340
Room Sizes
4,090
Frame Breaks
3.STRUCTURE
Room Sizes
Overall Frame
Notes
Notes
4.ENCLOSURE
Room Sizes
Room Sizes
Room Sizes
Kitchen
4,000
90
3,910
4,000
190
Bedroom Three
4,340
90
90
920 90
945 90 305
90
205
90 90
500
90
90
2,190
3,005
90
2,190
7,630
2,820
90
945 90
90
600
90
1,400
90
3,005
7,820
90
2,190
1,200
90
3,260
90
6,030
490 310 220
1,115
90 90 90
1,360
890
490
90
1,400
90
2,625
2,740
DRAWN BY: JOSH BINNIE
90
CHECKED BY: TONY WHEAL
1,650
3,335
90
3,155
555
90
1,275 100
12,910
90
1,200
90
1,600
868
100
1,000
1,200
210 1,200
868
550
980 90
90
1,535
90
1,200
90
555
90
1,640
6,725
5,900
4,800
1,400
90
Internal Dimensions
2,200
Openings
490
6,340
Wall Junctions
90
Frame Breaks
6,520
Overall Frame
Drawing Scale: A3
FLOOR PLAN
1,620
Room Sizes
90
21,600
LOT 07 PARK LANE
90
D31
Garage
Toilet
90
1,560
90
240
Bathroom
3,300
90
W17*
4231HW
1,810
1,200
650
W11*
90
90
D14
3,910
555
2,550
90
1,450
D32
90
1,650
90
HWC
D18*
W15
W01
90
3,155
90
Garage
6.0m x 5.9m
D15
3,910
Bedroom One/Two
90
D14
5,900
Kitchen
4.3m x 3.1m
Landary
Bathroom
3.6m x 2.1m
W07*
90
2,110
Ensuite
90
D13
D12
90
W28
D08*
D03*
3,655
4711N
D09*
Bedroom Three
3.3m x 3.1m
Garage
W29*
DW
90
D22
D06
90
Bathroom
90
3,155
Kitchen/Bedroom Three
90
90
Toilet
1.2m
x
2.2m
D12
2,285
D11
D04
90
D01
Skylight
90
1,950
W31
7352
D05
D16
90
1,950
620
2,200
500 425
900
Openings
Wall Junctions
1,650
90
Skylight
6221
D19*
W10
Bedroom One
3.2m x 3.1m
1,200
Master Bedroom
4.0m x 4.0m
D07
D21
D16*
D10*
Study Nook
Dining
3.9m x 3.5m
240
90
3,155
90
1,860
90
310
3,245
500
1,450
Bedroom Two
3.2m x 3.1m
D17*
2,605
D02
6511
Walk in Robe
D15*
Walk in Robe
1.5m x 2.6m
D20
90
4,045
Master Bedroom
90
1,200
W18*
D23
Dining
3,535
5,335
Living
265 360
90 900 90 90
90
4,825
Living
3.9m x 5.3m
Toilet
2,200
2,200
90
Living
Frame Breaks
W19*
D13*
5113G
90 360
5,335
5,515
12,910
Carpeting
Overall Frame
Floor tiling
6511
4238S
D24
D30
6.FINISH
6221
3155M
W06
1,800
GIB plasterboard linings
3421a
W08*
90
90
5113G
D29
190
5.INTERIOR
Ensuite
3.0m x 2.1m
W14*
Internal Dimensions
InsulPro Novatherm and Novafloor
insulation
2,200
4711N
W04
W05*
500
Supercrete 50 Panel Cladding
385 345 720 90
90
680 90 90
755
4238S
W03
weatherboard
90
Hardie
2,110
James
cladding
2,200
4231HW
Sheet no:
Date: 11 / 12 / 13
1:50
Status
Revision: 1
Revision
Notes
BATHROOM EXTRACTOR
VENTING 166.068M MINIMUM
ER HOUR THROUGH SOFFIT
2
2
2
DOWNLIGHT
2
2
DOUBLE POWER
OUTLET
SINGLE SWITCH
DOUBLE SWITCH
BATHROOM EXTRACTOR
VENTING 166.068M MINIMUM
ER HOUR THROUGH SOFFIT
WIRING
2
BATHROOM EXTRACTOR
VENTING 240.36M PER
HOUR MINIMUM,
THROUGH SOFFIT
Meter Box
Ground Floor Lighting/RCP
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:100
Drawing Scale: A3
ELECTRICAL PLAN
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
4.ENCLOSURE
4231HW
James Hardie
cladding
weatherboard
4238S
Supercrete 50 Panel Cladding
4521
Aluminium windows and doors
4555
Garage doors
Double glazed aluminium joinery
Raked soffits
throughout comprising
4.5mm Hardisoffit on
BRIX steel framed
sprockets and ribbon
board and inserted
into the groove in the
metal fascia
7.SERVICES
7411D
Dimond
systems
rainwater
Supercrete 50mm AAC panel cladding on
25mm steel Rondo battens on building
wrap on Brix steel framing
spouting
Superclad panel over timber post on
Bowmac bracket (see detail)
Linea wetherboard on CAVIBAT
cavity battens on BRIX steel
frames
Coloursteel sectional
garage door
Coloursteel "Endura" VeeDek corrugated
steel roofing at 9 on self-suporting roofing
underlay on BRIX steel roof faming
ROOF PITCH 9
4311D
ROOF PITCH 13
D20
7411D
4521
W31
W05*
D21
Coloursteel fascia and gutter
W18*
D22
4238S
FGL
D10
D35
4555
South Elevation
Double glazed aluminium joinery
Superclad panel over timber post on
Bowmac bracket (see detail)
1:100
8kN strap bracing tied to top and bottom of
panel roof, and at intermediate nogs &
rafters with 2 x 10/16/16 tek screws
Supercrete 50mm AAC panel cladding on
25mm steel Rondo battens on building
wrap on Brix steel framing
Coloursteel fascia and gutter
Coloursteel "Endura" VeeDek corrugated
steel roofing at 9 on self-suporting roofing
underlay on BRIX steel roof faming
Raked soffits throughout comprising 4.5mm
Hardisoffit on BRIX steel framed sprockets and
ribbon board and inserted into the groove in the
metal fascia
Linea wetherboard on
CAVIBAT cavity battens
on BRIX steel frames
4311D
D25
7411D
D24
4521
W01
D23
SAFETY GLAZING REQUIRED
4238S
D22
W11*
D27
W15
W07*
W17*
D26
Meter
box
D28
4231HW
West Elevation
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
ELEVATIONS SOUTH
AND WEST
1:100
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
4.ENCLOSURE
4231HW
James Hardie
cladding
weatherboard
4238S
Supercrete 50 Panel Cladding
4521
Aluminium windows and doors
Supercrete 50mm AAC panel cladding on
25mm steel Rondo battens on building
wrap on Brix steel framing
7.SERVICES
7411D
Dimond
systems
rainwater
Coloursteel "Endura" VeeDek
corrugated steel roofing at 9 on selfsuporting roofing underlay on BRIX
steel roof faming
Superclad panel over timber post on
Bowmac bracket (see detail)
spouting
Linea wetherboard on
CAVIBAT cavity battens
on BRIX steel frames
Double glazed aluminium joinery
ROOF PITCH 13
Raked soffits throughout comprising
4.5mm Hardisoffit on BRIX stel
framed sprockets and ribbon board
and inserted into the groove in the
metal fascia
ROOF PITCH 9
7411D
4521
D17
4238S
D18
Coloursteel fascia and gutter
D21
SAFETY GLAZING REQUIRED
D19
4231HW
W10
FGL
W06
North Elevation
1:100
Double glazed aluminium joinery
8kN strap bracing tied to top and bottom of
panel roof, and at intermediate nogs &
rafters with 2 x 10/16/16 tek screws
Superclad panel over timber post on
Bowmac bracket (see detail)
Skylight
Supercrete 50mm AAC panel cladding on
25mm steel Rondo battens on building
wrap on Brix steel framing
Coloursteel "Endura" VeeDek corrugated
steel roofing at 9 on self-suporting roofing
underlay on BRIX steel roof faming
4311D
Coloursteel fascia and gutter
7411D
4521
D24
4238S
W19*
W14*
SAFETY GLAZING REQUIRED
W04
D23
Raked soffits throughout comprising
4.5mm Hardisoffit on BRIX stel
framed sprockets and ribbon board
and inserted into the groove in the
metal fascia
W03
East Elevation
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
ELEVATIONS NORTH
AND EAST
1:100
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
3.STRUCTURE
3155M
Maxraft Floor System
3411e
90x45 Steel roof frame
3421a
Light steel framed buildings
ground floor
Interior and exteriorground floor
walls to be 90x45mm 0.55mm
galv. c-section steel studs at
450 CRS
3421AX
Axxis steel for framing
4.ENCLOSURE
4231HW
James Hardie
cladding
weatherboard
4238S
4311D
Supercrete 50 Panel Cladding
Dimond Profiled Metal Roofing
4521
Aluminium windows and doors
4711N
InsulPro
Novatherm
Novafloor insulation
and
5.INTERIOR
5113G
D07
Skylight
GIB plasterboard linings
10mm GIB standard interior lining fixed
to manufacturers specifications
2.5 Insulpro insulation to
manufacturers specifications to
exterior walls
13mm GIB ceiling lining on
35mm steel battens fixed to
underside of steel framing
Coloursteel "Endura" VeeDek
corrugated steel roofing at 9 on selfsuporting roofing underlay 45x70
Purlins on BRIX steel roof faming
Double glazed aluminium joinery
3.8 Insulpro insulation to
manufacturers specification
Linea wetherboard on
CAVIBAT cavity battens
on BRIX steel frames
4311D
3411e
3421AX
5113G
D33
D04
4521
3421a
D05
4231HW
MASTER BEDROOM
Coloursteel fascia
and gutter
HALL
BEDROOM 3
D06
5113G
Raked soffits throughout
comprising 4.5mm
Hardisoffit on BRIX stel
framed sprockets and
ribbon board and inserted
into the groove in the metal
fascia
Supercrete 50mm AAC panel
cladding on 25mm steel Rondo
battens on building wrap on
Brix steel framing
4238S
Supercoat coating
system
3155M
Section AA
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:50
Drawing Scale: A3
SECTION A-A
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
3.STRUCTURE
3155M
Maxraft Floor System
3411e
90x45 Steel roof frame
3421a
Light steel framed buildings
ground floor
Interior and exteriorground floor
walls to be 90x45mm 0.55mm
galv. c-section steel studs at
450 CRS
3421AX
Axxis steel for framing
4.ENCLOSURE
4231HW
James Hardie
cladding
weatherboard
4238S
4311D
Supercrete 50 Panel Cladding
Dimond Profiled Metal Roofing
4521
Aluminium windows and doors
4711N
InsulPro
Novatherm
Novafloor insulation
and
5.INTERIOR
5113G
GIB plasterboard linings
D11
3.8 Insulpro insulation to
manufacturers specification
4311D
2.5 Insulpro insulation to
manufacturers specifications to
exterior walls
Double glazed aluminium joinery
D08
Supercrete 50mm AAC panel cladding on
25mm steel Rondo battens on building
wrap on Brix steel framing
4711N
Supercoat coating system
4238S
10mm GIB standard interior lining fixed
to manufacturers specifications
13mm GIB ceiling lining
fixed to underside of steel
framing
Skylight
D36
Coloursteel "Endura" VeeDek
corrugated steel roofing at 9 on selfsuporting roofing underlay on BRIX
steel roof faming
Raked soffits throughout comprising
4.5mm Hardisoffit on BRIX stel
framed sprockets and ribbon board
and inserted into the groove in the
metal fascia
3411e
3421AX
5113G
3421a
D09
4231HW
Linea wetherboard on
CAVIBAT cavity battens
on BRIX steel frames
D10
4521
3155M
Maxraft waffle slab foundation system
Section BB
1:100
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
Drawing Scale: A3
SECTION B-B
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
4,090
4,340
5,880
3,200
4,090
4,562
C2 GS1S 1500
F2 GS1S 700
F3 GS1S 1100
O1 GS2S 2250
D2 GS2S 2270
N2 GS2S 2600
E3 GS2S 500
N1 GS2S 2800
E2 GS2S 1500
D1 GS2S 3200
C1 GS1S 1800
B1 GB1S 1800
A1 GB1S 2300
3,245
M1 GS1S 3300
2,720
E1 GS2S 1500
F1 GS1S 700
M2 GS1S 1000
P
P1 GS1S 2700
Ground Floor Bracing Plan
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
F4 GS1S 500
P2 GS1S 1200
1:100
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
10,030
6,880
Fall
1,650
900
Fall
Fall
7,280
FALL = 13
SKYLIGHT
12,260
SKYLIGHT
5,868
FALL = 9
Fall
TOTAL ROOF AREA = 298.51m
59m OF ROOF AREA PER DOWNPIPE,
5 63mm DOWNPIPES
Fall
DIMOND COLORSTEEL ENDURA
VEEDEK LONG RUN STEEL
ROOFING
Fall
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
Drawing Scale: A3
ROOF PLAN
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
500
500
500
2,200
500
500
1,100
1,300
1,200
1,300
2,200
1,400
2,200
300
W01
x2 (W03, W04)
W05
W06
1,600
W07
W08
W10
1,600
1,000
930
500
1,100
1,100
1,400
x2 (W11, W17)
x3 (W14, W18, W19)
W15
W31
Window Schedule
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
WINDOW AND DOOR
SCHEDULE
1:50
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
x2 (D01, D07)
1,000
D02
D03
2,625
2,025
2,025
1,488
2,025
1,530
2,025
900
2,025
Notes
D04
D05
1,000
x4 (D08, D09, D16, D17)
900
D11
2,595
D14
1,010
2,025
2,025
2,025
2,025
D13
D10
900
2,100
900
2,200
2,200
2,025
D06
D12
5,500
900
2,025
2,110
D15
D18
Door Schedule
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:50
Drawing Scale: A3
DOOR SCHEDULE
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
1,600
2,400
3,365
D19
2,400
2,400
2,025
2,400
1,535
D20
x2 (D21, D24)
D22
2,400
3,400
D23
Door Schedule
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:50
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
90X45 engineering steel frame
2.5 InsulPro insulation
10MM GIB adhesive fixed with
5mm floor junction gap to
manufacture's specification
Building paper continued
below bottom plate
M10 75mm screw bolt with
50x50x3 square washer
50mm supercretetm panel
90X45 bottom plate on dpc fixed to
steel frame wall
303 GIB Rondo batten
Bottom of panel and lower 20mm of
panel face coated with supercoat
tanking membrane
4/HD12 longitudinals
35 cover bottom & sides
100
250
Supercoat tanking membrane on
base and back of slab
HD10 stirrups alternating
@300crs
250
100
Textured plaster coating to
foundation end
225
10mm overhang drip edge
50
protectotape, poly, polythene join
Solid compaction
800mm past
foundation line
150mm
EPS
50
50
550
Maxraft slab to wall
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
665 mesh, 30
cover top
R6 Stirrups @ 300crs
35 cover bottom & sides
50
100
100
2 HD12 longitudinals
150mm S-Grade
EPS
Solid
Compaction
50mm VH-Grade EPS
under slab thickening
450
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
Maxraft non LBW
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
Load bearing wall
R6 Stirrups @ 300crs
35 cover bottom & sides
665 mesh, 30
cover top
50
100
100
2 HD12
longitudinals
150mm S-Grade
EPS
Solid Compaction
50mm VH-Grade EPS
under slab thickening
450
Maxraft LBW
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
Timber cavity batten
Scyon Linea Weatherboard
Building underlay/James Hardie rigid air barrier
Additional building underlay or flashing tape over flashing
Nog as required
35mm min
H3.1 treated timber cant strip
Flashing 15 min slope
Flexible flashing tape at corners
Continue building underlay around framing
15mm
Airseal around all sides of meter box
Metal meter box
Line of scriber beyond
Metal angle sealed and riveted to box
Note:
When James Hardie rigid air barrier is used
flashing tape to be applied to the entire
opening.
Flexible flashing tape at corners
Meter box head
1:5
Metal meter box
Continuous sealant to metal angle
Metal angle to be sealed and riveted in place.
Site cut edges to be primed prior to installation
Airseal around all sides of meter box
Continue building underlay around framing
Scyon Linea Weatherboard
Timber cavity batten
Building underlay/James Hardie rigid air barrier
Building underlay/James Hardie rigid air barrier
60mm x 8 10g screw at 90 to face.
Finish 2mm below surface and fill
Timber cavity batten
Note:
When James Hardie rigid air barrier is used flashing
tape to be applied to the entire opening.
Selected interior lining
Scyon Linea Weatherboard
Flashing tape 100mm upstand on jamb
Line of head flashing above, extends past scriber
20mm min.
8mm ga p no min al
10mm mi nc ove r
Waterproof air seal
Meter box sill
1:5
Scriber
Window liner
Window frame (refer to window manufacturer
for method of support and fixing)
Note:
When James Hardie rigid air barrier is used
flashing tape to be applied to the entire
window opening.
Meter box jamb
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
UP TURN
DIMOND TOP HAT RIDGE
FLASHING
35
1050
35
VEEDEK LONG
RUN ROOFING
12g x 25mm type 17 or
4.8 aluminium rivets @
TEK SCREW THROUGH
CORNERS @600 CRS
135
BUILDING
PAPER
0.55 Flashings
1000mm c/c max
90x45 steel rood frame
tek screrw fixed
Soffit lining installed
before cladding
Dimond Veedek roofing
Climaseal coated self
drilling m6 x 50mm
roofzip fixed
90x45 mm STEEL
SUPPORT WALL
90x45 mm STEEL
ROOF FRAME
150
Notes
Rondo 303 steel batten
14 -10 x 65 mm bugle head screw
90x45 steel wall framing tek screrw fixed
Supercrete 50 Panel cut to suit soffit height
Building paper/wall wrap
Supercoat Coating System
InsulPro R2.5 insulation to
manufactures specifications
Ridge beam connection
1:5
verge overhang details
VELUX SKYLIGHT
FRAME
1:5
EDW HEAD FLASHING
EDW BOTTOM FLASHING
ROOFING UNDERLAY
DIMOND COLORSTEEL ENDURA VEEDEK
STEEL LONG RUN ROOFING
TIMBER ROOFING BATTENS FOR
THERMAL BREAK
GIB CEILING LINING ON 35MM
STEEL BATTENS
3
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
Velux skylight detail
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
DIMOND COLORSTEEL ENDURA VEEDEK LONG RUN STEEL
ROOFING FIXED ON 35X75 TIMBER BATTENS FOR THERMAL
BREAK TO MANUFACTURERS SPECIFICATIONS
ROOFING UNDERLAY
200 STEEL WEB JOIST
4.5mm HARDIESOFFIT SOFFIT
LINING
13mm CEILING GIB
STANDARD ON 35MM
STEEL BATTENS @
450 CTRS
SUPERCRETE 50mm ACC PANEL
CLADDING ON 25mm STEEL
BATTENS ON BUILDING WRAP ON
BRIX STEEL FRAMING
10mm GIB STANDARD
BUILDING WRAP
SUPERCOAT
COATING SYSTEM
Negative soffit detail
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
10
14 - 10 x 65 mm bugle head screw
Supercrete 50 Panel
Building paper/wall wrap
Sealant (Holdfast FIX ALL 220LM
MS) and hold fast backing rod
InsuPro R2.5 insulation
Movement control joint
Supercrete 50 Panel
cantilevers 75 mm past its
support wall to align with the
perpendicular wall face
Supercoat Coating System
90x45 Steel framing
10mm GIB adhesive fixed to
manufactures specifications
Tek screw fixed
Building paper/wall wrap
Sealant (Holdfast FIX ALL
220LM MS) and Holdfast
backing rod
Movement control joint located
on shorter panel side where this
is a consideration
Supercoat
Coating System
90x45 Steel framing tek screw
fixed
14 - 10 x 65 mm
bugle head screw
10mm GIB adhesive fixed to
manufactures specifications
Rondo 303 steel batten
InsuPro R2.5 insulation
INTERNAL CORNER
2
Supercrete internal corner
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:5 1
Supercrete external corner
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
Scyon Linea
Weatherboard
Face nail weatherboards to
corner stud only
Compound mitre corner
of weatherboards,
prime ends and join
with adhesive sealant.
60
Building underlay
continuous around
corners James Hardie
rigid air barrier
90X45 STEEL FRAMING
BUILDING WRAP
50mm x 50mm uPVC
corner underflashing over
building underlay/James
Hardie rigid air barrier
Note:
Adhesive sealant must be used on the full end face
of both weatherboards. Push tightly together and
wipe off excess.
INSULPRO INSULATION
10mm GIB STANDARD,FIXED TO
MANUFACTURERS SPECIFICATIONS
Linea external corner
CAVITY BATTEN
1:5
SUPERCOAT COATING SYSTEM
Building underlay/James Hardie rigid air barrier
SUPERCRETE 50 PANEL
Fix at 600mm centres
35mm Steel cavity batten
Bottom plate
MOVEMENT CONTROL JOINT &
SEALANT (HOLDFAST FIX ALL 220LM MS)
AND HOLD FAST BACKING ROD
25mm wide cant strip. H3.1 treated timber.
Thickness to suit selected weatherboard.
D.P.C.
Scyon Linea Weatherboard
50
Concrete slab / footing
30
SYCON LINEA WEATHERBOARD
James Hardie
uPVC vent strip. Mitre at corners.
0
2 mm no mi nal cav ti y
Drain holes in James Hardie uPVC
vent strip are sufficient to achieve
ventilation openings of 1000mm per
lineal metre
150mm min to permanent paving or 225mm
min to unpaved ground to clause 9.1.3 of
E2/AS1
weatherboard foundation detail
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
Cladding junction
1:5
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
InsulPro R2.5
insulation
Supercoat Coating System
Building paper/wall wrap
14 - 10 x 65 mm bugle head screw
10mm GIB adhesive
fixed to manufactures
specifications
Rondo 303 steel batten
Flexible self adhesive flashing tape over DPC to
Building paper/wall wrap
90x45 steel
framing
Tek screw fixed
Sealant (Holdfast FIX ALL 220LM MS)
10mm GIB adhesive fixed to
manufactures specifications
15 slope
Packer and air
seal
DPC head flashing
Timber jamb liner
Supercrete 50 Panel
InsulPro R2.5 insulation
90x45 steel framing
Packer and air seal
Supercrete window head
Supercrete 50
Panel
Supercoat Coating
System
14 - 10 x 65 mm
bulge head screw
Architrave
Aluminium window joinery
Timber jamb liner
Building
paper/wall wrap
1:5
12 - 11 x 25mm hex
head type 17 batten
screw
The front flange of the
window joinery to be
40 mm minimum from
stud face
Aluminium window
joinery
The front flange of the window joinery to be
40 mm minimum from stud face
Aluminium window joinery
DPC sill flashing fastened to top of sill and bent
over behind panel and over batten
Timber jamb liner
Sealant (Holdfast FIX ALL 220LM MS)
Packer and air seal
Supercoat Tanking Membrane Keycoat on sill
applied by the Supercoat Coating Applicator
90x45 steel framing
Superbond Adhesive or Superbuild Render used
to build up top of panel behind sill block
10mm GIB adhesive
fixed to manufactures
specifications
Supercoat pre meshed
render stop glued to panel
with Holdfast FIX ALL 220
LM MS. Adhere mesh
around corner as required.
30slope on sill
Sill block glued to panel
(Raised 1 - 2 mm above panel at rear)
Tek screw
Steel batten
Initial gap between
joinery and panel
filled with sealant
proir to placement of
supercoat pre
meshed render stop.
14 - 10 x 65 mm bugle head screw
InsulPro R2.5 insulation
Supercoat Coating System
Building paper/wall wrap
Supercrete 50 Panel
2
3
Supercrete window sill
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
Gap between joinery and
bottom of supercoat. Pre
meshed render stop filled
with sealant (Holdfast FIX
ALL 220LM MS)
Supercrete window jamb
1:5
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
Timber cavity batten
Proprietary tape or alternatvely additional
layer of building underlay over head
flashing
Lintel
Scyon Linea Weatherboard
H3.1 treated timber cant strip
Selected interior lining
James Hardie uPVC vent strip
5
1 mm
60mm x 8 - 10g screw at 90 to face,
finish 2mm below surface and fill
Flashing tape over underlay
required in corners only
5mm
min
8mm g ap n omi na l
0
1 mm mi nco ve r
Aluminium head flashing
to min 15 slope
Building underlay/James
Hardie rigid air barrier
Waterproof air seal
Window frame (refer to window
manufacturer for method of
support and fixing)
Window liner
Temporary packers if required to
be removed after fixing
60mm x 8 - 10g proprietry screw at 90 to
face, finish 2mm below surface and fill
Timber cavity batten
Selected interior lining
Scyon Linea Weatherboard
Linea window head
Line of head flashing above, extends
past scriber 20mm min.
1:5
Waterproof air seal
8mm ga p no mi nal
Flashing tape 100mm upstand on jamb
Scriber
Window liner
Window frame (refer to window manufacturer
for method of support and fixing)
Window frame (refer to window
manufacturer for method of
support and fixing)
Linea window Jamb
1:5
For flashing tape detail refer to
Figures 72 and 91 of NZBC clause
E2/AS1.
Timber cavity batten
Scyon Linea
Weatherboard
Waterproof airseal to
perimeter of trim cavity with
expandable foam or sealant
8mm gap nominal
10mm min
Window support as supplied by
window manufacturer
Window
liner
Selected interior lining
Linea window sill
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
24mm
10mm GIB
adhesive fixed to
manufactures
specifications
Interior lining
Supercoat Coating System
Building paper/Wall Wrap
Steel Batten
Building paper/wall wrap
14 - 10 x 65 mm bugle head screw
Rondo 303 steel
batten
Supercrete panel
Flexible flashing tape fitted by a
Licenced Supercrete Panel
Installer to attach the DPC head
flashing to the building
paper/wall wrap
InsulPro R2.5 insulation
to manufactures
specifications
14-10 bugle head screw
65mm for 50mm panels and
90mm for 75mm panels
Steel framing
Architrave
Packer and air seal
Aluminium joinery 40mm
from front flange to framing
Tek screw fixed
90x45 steel frame
Packer and Air seal
Timber jamb liner
Supercrete 50 Panel
Timber jamb liner
Gap between joinery and panel
filled with sealant (Holdfast FIX ALL
Internal opening door
220LM MS) and covered
by acrylic coating
DPC head flashing secured under
battens and turned up against panel
Internal opening door
Timber jamb liner
5 slope
Aluminium door
header framing
40 mm from front
flange to frame
Supercrete Door head
1:5
Aluminium door sill framing
40 mm from front flange to frame
Tiled or plastered edge installed
by the owner 20 mm minimum below
door sill rebate
15 x 15mm plastic
angle glued to joinery
with construction
adhesive prior to
panel installation
Alternative 2
Joinery at maximum
distance from stud
framing
5 slope
Supercrete door sill
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
Supercoat pre-meshed
render stop glued to panel
using Holdfast FIX ALL
220LM MS. Adhere mesh
around corner as required
5mm
Alternative 1
Joinery at minimum 40mm
from stud framing
40mm min
Poured concrete in-fill under door
installed by the owner, Supercrete
optional for low foot traffic areas
Supercoat coating system
5mm
Gap between joinery and
Supercoat pre-meshed
render stop filled with
sealant (Holdfast FIX ALL
220LM MS)
Initial gap between joinery and
panel filled with Holdfast FIX
ALL 220LM MS sealant prior to
placement of Supercoat premeshed render stop
Steelocka unique
steel top hat batten
mounting system.
Thermoseal a
unique thermally
efficient closed
cavity cladding
system.
Supercrete door jamb
1:5
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
Building underlay/James
Hardie rigid air barrier
Scyon Linea
Weatherboard
60 x 3.15mm jolt head
nails pre-drill with 3mm
drill before fixing
Line of head flashing over,
extends past scriber min
10mm
Selected interior lining
Scriber cut fit board
Note wider stud required
H3.1 treated timber
packer to suit
Scyon Axent Trim. Mitre or extend to
top of head flashing fix with 75mm x
3.15mm jolt head nails
50mm flathead @ 400mm
centres
Lintel
Scyon Linea Weatherboard
Face nail weatherboards
to lintel
*Outer face of
weatherboard
Selected interior lining
5m m
10mmmin cover
10
Aluminium head flashing with 15
slope
Flashing tape over underlay
required in corners only
8mm gap
nominal
H3.1 treated timber cant strip
70mm H3.1 treated timber packer to suit
Waterproof
air seal
Scyon AxentTM
Trim
Window liner
5m mg ap m n
i .
Fixed at 400mm centres
staggered nailing
Window frame (refer to
window manufacturer for
method of support and fixing)
5mm x 3mm inseal 3109
optional
Sill flashing position
Planted sill
60 x 3.15mm jolt head nails pre-drill
with 3mm drill before fixing
min
50mm strip of sealant at both ends
of flashing
Waterproof air seal
8mm g ap n omi na l
Proprietary tape or alternatively
additional layer of building
underlay over head flashing
Flashing tape 100mm upstand
on jamb
TM
10
Linea door jamb
Temporary packers if required are to
be removed after fixing
1:5
Aluminium door sill framing
40 mm from front flange to frame
Window liner
No te :
Whe n Ja mes Ha d
re
i irgi d a ri ba ri er si use d fla shi ng ta pe to b e ap pl e
i d to th e en tire win do wo pe ni ng.
Se al ant mus t b e n
i stal e
l d be twe en h ea d fla shi ng and tri m n
i VH and EH win d zo ne s. Re fe rto Fig ure 7 1 of E2 /AS1
70mm x 35mm H3.1 treated timber packer
Tiled or plastered edge installed
by the owner 20 mm minimum below
door sill rebate
5mm x 3mm inseal 3109
optional
Window frame (refer to window manufacturer
for method of support and fixing)
Linea Door head
Poured concrete in-fill under door
installed by the owner
1:5
5 slope
3
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
Linea door sill
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
Apply continuous 6mm bead of
Seal n Flex -1 or Sikaflex 11FC
adhesive sealant
10mm GIB adhesive fixed
to manufactures
specifications
Tek screw fixed
Sycon Linea weatherboards
Building paper/wall wrap
10mm GIB adhesive fixed to
manufactures specifications
Sycon linea weatherboards
Selected nail / screw
for Weatherboard
fixing
InsuPro R2.5 insulation
InsulPro R2.5 insulation to
manufactures specifications
90x45 steel frame
Door jamb located 40 mm
from front edge to frame
Packer and air seal
Tek screws hidden under
overlapping weatherboard
Packer and airseal
Rebated garage door jamb
installed by owner, treated
to H3.1 and painted
Packer and air seal
Building paper/wall wrap
DPC jamb flashing
Flashing tape 100mm
upstand on jamb
Garage door
Rebated timber
garage door
liner frame installed
by owner, treated to
H3.1 and painted
DPC flashing
Garage door jamb
GIB INTERNAL LINING
Sealant (Holdfast FIX ALL 220LM MS)
and Holdfast backing rod
GARAGE DOOR
JAMB LINER
90x45MM FRAMING
Galvanised steel head flashing installed
by a Licenced Hebel Supercrete Panel
Installer prior to panel installation
DOMINATOR SIERRA
SECTIONAL GARAGE DOOR
30MM RECESS
IN SLAB
30
Door liner located 40 mm
from front edge to frame
100
1:5
Garage door opening
15
Steel track for garage door
40
Garage door head
COMPACTED
HARDFILL
UNDER
DRIVEWAY
1:5
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
Garage door rebate
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision
Notes
Silicone sealant required see bath
manufactures details
GIB Aqualine
GIB Aqualine
Silicone sealant or tile edge bead
Ardex WPM 002 water proof
membrane
Ceramic tile
Silicone sealant
Ardex WPM 002 water proof
membrane
Silicone sealant
Silicone sealant
Gib Goldline L trim
Silicone sealant required see bath
manufactures details
Ardex WPM 002 water proof
membrane
GIB Aqualine
Silicone sealant
Ceramic tile
Vanity top
Silicone sealant
6mm
Proprletary bath installed to
manufactures specifications
Silicone sealant
between vanity and
wall
Ceramic tile
Silicone sealant
Wet area, bath to wall
1:5
Wet area, bath to tiles
1:5 5
Wet area, vanity
1:5
ARDEX WPM 002 WATER PROOF
MEMBRANE
90x45 steel frame tek
screw fixed
Silicone sealant
10MM X1.2M X 2.4M MARMOX SAFE
GUARD SECONDARY WATERPROOF
WALL LININGS GLUED AND SCREWED
@ 300 CNT
GIB Aqualine
FLEXIBLE SEALANT BONDBREAKER ON ALL INTERAL
CORNER JOINTS
Ardex WPM 002 water proof
membrane
MARMOX SAFE
GUARD
SECONDARY
WATERPROOF
PREFORMED
SHOWER TRAY
UPSTAND BACK FLASHING ON ALL
INTERNAL CORNER JOINS
MARMOX SAFE GUARD SECONDARY
WATERPROOF PERFORMED SHOWER
TRAY
Ceramic tile
DWANGS TO SUPPORT BACK
FLASHINGS
Ceramic tile
Silicone sealant
STEEL JOIST
LEAKPROOF PUDDLE
FLANGE
80MM GULLY TRAP
22mm H3.2 T&G ply
used in wet areas
Grout per manufactures
specification
Wet area, tiles
LOT 07 PARK LANE
DRAWN BY: JOSH BINNIE
CHECKED BY: TONY WHEAL
1:5
Wet area, shower tray
1:5
Drawing Scale: A3
Sheet no:
Status
Date: 11 / 12 / 13
Revision: 1
Revision