0% found this document useful (0 votes)
180 views

E Microscope Manual Eng

4 in 1 Petit E. Microscope is easy to install and use. Initial hardware and software setup must be done by an adult. This microscope will work on computers equipped with a USB 1. Port.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
180 views

E Microscope Manual Eng

4 in 1 Petit E. Microscope is easy to install and use. Initial hardware and software setup must be done by an adult. This microscope will work on computers equipped with a USB 1. Port.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 26

4 in 1 Petit Microscope

4 in 1 E-Microscope
Select by Clicking on Your
Microscope Model
New Generation Digital
Microscope
Parent Quick Start Guide (E Microscope)

While 4 in 1 Petit E. Microscope is easy to install and use, the initial
hardware and software setup must be done by an adult. Please follow
the instructions below to get started.

It is important to install the software first. This microscope will work on
computers equipped with a USB 1.1 port (USB 2.0 recommended) and
Windows2000, WindowsXP SP2 or WindowsVista. Driver
installation for Windows2000 system is mandatory. Driver installation
for XP SP2 and Vista systems is optional and only required if your
computer has issues using this microscope in driverless mode.

1. Insert the installation CD.

2. Wait for the autoplay to start.
(If Autoplay does not automatically launch the installer, go to the
desktop and double-click on the icon named My Computer.
Double-click the icon for the CD-ROM/DVD drive that contains the E.
Microscope software. Sometimes this will cause Autoplay to start. If
it doesnt, double-click on the autorun.exe, and follow the setup
steps on this page.)

3. This step is optional for Windows XP SP2 and Vista users, you do
not need to install driver. You can jump to step 4. However, you can
install driver if you really want to. For Windows 2000 users, you
must install driver first: Connect the microscopes USB plug to the
USB port of the computer. Install the microscope driver by clicking
Install Driver. Follow the on screen instructions to complete the
installation.

4. Install the ArcSoft camera suite by clicking Install PhotoImpression
and Install VideoImpression on the menu screen. Input the license
key found on the CD sleeve if prompted.

5. Follow the steps by clicking the appropriate buttons.

6. You need the Adobe Acrobat Reader software to open the manual.
Click Install Adobe Acrobat Reader if your computer does not have
this software.
7. If you have the Adobe Acrobat Reader software installed, you can
read the manuals for the Digital Microscope and the camera suite by
clicking Microscope Manual and ArcSoft Application Software
Manual on the menu screen respectively.

8. Insert the microscopes USB plug to the USB port of the computer. A
new device named USB 2.0 Camera will be detected on the first
time the microscope is plugged in. Start the PhotoImpression or
VideoImpression application to acquire image with the digital
microscope.



Under the environment with electrostatic discharge, the device
may malfunction and require user to reset the device.


- ii -
- i -
Package contents:
1. Microscope
2. Digital camera (with lens, USB cable and stand)
3. 1 Eyepiece adaptor for web camera
4. 4 prepared slides
5. 8 blank slides
6. 12 blank labels
7. 12 slide covers
8. 12 cover glasses
9. 1 pair of metal tweezers
10. 1 preparation needle
11. 1 Software CDROM
12. This manual

Minimum system requirements:
A computer with USB port
Intel Pentium 4 Processor or AMD Athlon XP or faster
256MB System RAM
Windows 2000/XP SP2/ Windows Vista
CD-ROM drive
16-bit color display or higher

Software setup guide
For Windows 2000 users, please install the microscope driver software first.
However, for Windows XP SP2 or Vista users, this digital microscope does not
require any driver installation. Driver installation for XP SP2 and Vista systems
is optional and only required if your computer has issues using this
microscope in driverless mode. In any case, you need to use an imaging and/or
a video application software to capture the images from the digital microscope.
You can use your favorite application or the ones provided on the software
CDROM:
1. Insert the software CDROM to your CDROM drive
2. Wait for autoplay to start
3. If the installer screen does not come up automatically, click Start, Run,
and execute the file autorun.exe of the CD to start the installation program.
4. This step is optional for Windows XP SP2 and Vista users, you do not need
to install driver. You can jump to step 5. However, you can install driver if you
really want to. For Windows 2000 users, you must install driver first:
Connect the microscopes USB plug to the USB port of the computer. Install
the microscope driver by clicking Install Driver. Follow the on screen
instructions to complete the installation.
5. Install ArcSoft Camera Suite by clicking Install PhotoImpression and
Install VideoImpression on the installer screen. Input the license key found
on the CD sleeve if prompted.
Connecting the Digital Microscope:

1. After the E-Microscope software has been installed, plug the microscopes
USB cable into your computers USB port.
2. Go to the Windows Start menu to launch the imaging software like Arcsoft
PhotoImpression, for example.

Note:
For the location of the USB ports on your computer, please refer to your
computers user manual. To ensure that the digital microscope works normally, do
not connect or disconnect the USB cable from the computer while system is
starting up or shutting down. To avoid unstable system software functioning, do not
connect or disconnect the USB cable while application is opening or closing.

If you want to disconnect the digital microscope when the computer is on,
remember to:
1. Close any software application that currently using for the microscope.
2. Disconnect the USB cable.

Never pull on the cable portion to disconnect the USB cable, always grasp the
connector itself while disconnecting.
Note that the computer may not be able to recognize the microscope if it is
disconnected and then reconnected while the computer is in power saving mode.

Using the Microscope in Digital Mode:

















- 2 -
- 1 -
1. If you have been using the digital camera module as a web camera,
unscrew the objective lens unit from the camera (figure 2a), then replace
with the eyepiece adaptor (figure 2b).















2. Remove the eyepiece on the microscope (Figure 3a). Snap the digital
camera module in the eyepiece position (Figure 3b), make sure the camera
module sits properly in place.



















3. Make sure the microscope is connected to the USB port of the computer.

- 3 -
4. Install two AA size batteries (not included) in the battery compartment near
the arm of the microscope.










5. Place the slide on the stage, fasten it in place with the clip and switch on the
illumination.

6. Start PhotoImpression program from the Windows Start menu. The
application will start with the Get Photo screen. Here you can select the
device which you get your photo from. If you have correctly connected the
Digital Microscope, you should be able to select the Video icon. (On some
systems, the Video icon may not be selectable. In such case, get photo
from Camera/Scanner and then select WIA-USB Video Device.)





















- 4 -
Figure 2a Figure 2b
Figure 3b
Figure 3a

7. A window Capture Image from Video will pop up, select USB 2.0 Camera
from the Drivers list.



















8. The image window will be blank. To preview the image from the microscope,
click the Live button.




















9. Set the image size to 640x480 in
the properties window by clicking
the Format button, smaller
image size (e.g. 352x288) is
recommended for slower
computers.
















10. If there is flickering in the preview
image, click the Source button. Try
selecting different PowerLine
Frequency (Anti Flicker) setting in
the Properties window until
flickering is reduced.















- 5 -
- 6 -
11. Focus:
Adjust the focus knob until the image on the computer screen looks clear.
Focusing may take a little practice. Try making small changes and waiting for the
screen to catch up.

Selecting different magnification:
You can choose different magnification power by rotating the magnification
revolving turret of the microscope. The current level is indicated on the
magnification level label facing you. You will feel a click if the lens is properly
aligned. Levels of 100X, 200X and 450X can be selected.


12. Press the Capture button to capture the current image. Press Done to
exit the Capture window.


























13. The captured image will appear in the main working area, select the
Enhance or Create icon near the top to edit the new image, or select Get
Photo again to capture another image. Refer to the manual of
PhotoImpression (in the supplied installation disc) for further details.


















Using the Microscope in non-Digital Mode:

1. Replace the digital camera module of the microscope with the removable
eyepiece for direct viewing (figure 4).














Figure 4
2. Focusing and magnification level selection are the same as in digital mode.

3. Please refer to the detail instructions of using the microscope starting from
page 12.


- 8 - - 7 -
Using the digital camera module as a PC camera:

1. Screw the objective lens unit back to the camera module if it has been
removed for microscope viewing. Care should be taken not to make
fingerprints or dust on the lens and the sensor of the camera.

2. Place the camera unit on the stand as shown below.

















3. Connect the camera module to the USB port of the computer
4. Start PhotoImpression or other Imaging applications from the Windows
Start menu.
5. Adjust the focus by rotating the lens until a clear image is displayed.
6. You can take still pictures and save them in the computer using the same
procedure as described in the section Using the Microscope in Digital
Mode.
7. To use the camera module as a web camera for video conference, you need
to install applications like Netmeeting or MSN Messenger, which can be
downloaded from Microsofts web site. Please refer to the corresponding
application manual.







- 9 -
Handling note:

The image sensor of the camera is a delicate integrated circuit and must be
handled carefully. When you remove the lens from the camera, dust may fall on
the sensor. Only use a blower to clean the dust. Never touch the sensor.

Technical Specifications:

Image Sensor: 1/4.5 inch color CMOS (310k effective pixels)
Color: 24 bit RGB
Interface: USB 2.0 (backward compatible with version 1.1)
Video Preview: 30fps @320x240 pixels (QVGA)
30fps @640x480 pixels (VGA)
Video Control: PC software provides control for brightness, contrast,
hue, saturation, sharpness, gamma, 50/60Hz flicker
filtering
Video Capture: 30fps @320x240 pixels (QVGA)
30fps @640x480 pixels (VGA)
Still Capture: 30fps @320x240 pixels (QVGA)
30fps @640x480 pixels (VGA)
Magnification: 100, 200, 450 (for 14 screen)





















- 10 -
Welcome to the world of
Micro-Science



We take great pleasure in introducing you to the
world of Microscope. Microscope refers to an
instrument with lenses for making very small
near objects to appear larger. Because there
are innumerable living things that cannot be
seen with our naked eyes, microscope enables
these invisible living things to be seen
effortlessly.

The discovery of microscope goes back many
many years, and since the invention it has
exposed to a new field of exploration and study
as more attractive, and exquisite specimens as
you ever imagined can be evidenced.

In our new world of advanced technology, every
science from the most fundamental study of
biology to the highly skilled fields of
astro-physiology will use some form of
microscope. The mission of microscope
allows anyone from all walks of life to better
comprehend the complex forms of living
organisms or stagnant materials that construct
this world which we live in.

This microscope set will be the starting point to
your many hours of fruition as a hobby or
broader your opportunity to a wonderful world of
science.

Happy Experimenting!!!

Attention

The following information should be read carefully
in order to overcome confusions.

This microscope set is appropriate for children over
8 years old. If not applied, supervision of adult is
required as this set comprises of functional sharp
edge.

Before using the microscope, attentively and
carefully read the instructions, follow the guide, and
keep them for future direction in case you need
further helpful hints.

In any situation, be extremely cautious not to allow
chemicals to come into contact with any part of the
body, especially the eyes and mouth. Keep away
young infants and animals from the experiment.
Always, keep the microscope set in a place where
young infant is out of reach.

Eye protection is not provided, it can be obtained
from any science departments, and major shopping
outlets. Remember, in case of accidents please
seek medical advice.

Helpful Hints

The essential component of the microscope is
the lens. Consequently, adequate care must
be exercised when dealing with the lens.
Microscope should be stored in a moisture
free place. Because moisture build up on the
lenses will reduce the light intensity.
After it is utilized, protect the microscope from
dust by covering the microscope or putting it
back into the box.
If the lens gets dusty or dirty, it is suggested to
clear off the lens surface with a soft cotton
cloth or tissue. Do not rub the lens with a
finger or unclean cloth.
If a microscope is not used for a long period of
time, discharge the light source batteries.

Always keep instructions to hand.

Components of a Microscope

1. Eyepiece
2. Focusing knob
3. Body tube
4. Objective lens
5. Arm
6. Stage
7. Clip
8. Clip adjustors
9. Power switches for the illuminator
10. Base
11. Magnification revolving turret





















Procedures

1. Firstly, insert 2 AA penlite dry cells batteries in
the arm of the microscope. You will need to
use a screwdriver to open the battery case
cover. (Batteries are not included)









2. Now put the prepared slide on the stage, and
fasten it in place with the clip adjustors.








3. Next, choose the magnification strength you
desire. In general, it is recommended to begin
with lower magnification for easier focusing.
To change the magnification setting, turn the
magnification revolving turret until you hear a
click.






4. Turn on the illuminator for viewing.

5. Look through the eyepiece and slowly adjust
the focusing knob until the object on the slide
becomes clear. To view different part of the
slide, adjust the clip adjustors until the desired
object appears through the eyepiece.

















































































1
3
11
4
6
7
8
10
2
9
5
How To Make a Prepared Slide

Please note that if the given specimen is not thin
and crystalline, it cannot be inspected by the
microscope. This is due to the fact that light from
the reflector or light source does not advance
through.

Fibres of wool, pollen, or salt will be simple to
see, and will not need a cover glass.
Crystal-clear specimen are stain first with a
drop or two drops of methylene blue. Eosin
or other dyeing solutions are available on the
market.

Also note these are dyeing solutions, and thus
could induce staining of clothing, fabrics, and
carpets. Extreme care should be handled with
when dealing with these solutions.



1. Temporary Mount

Wipe the slide and cover glass clean
Thin the sample with a razor blade. (Be
extremely careful)
Then pick it up with tweezers, and put it on the
centre part of the glass slide.
Next, add one drop of water on the sample
with a dissecting needle. If the sample is
clear, add one drop of methylene blue or eosin
solutions. (Be extremely careful)
Gently put the cover glass on top of it, be sure
not to let any air bubbles go in.
Remove any excess water or dyeing solutions
with blotting paper.
Now, it is ready for observation.

Remember to wash your hands immediately after
doing the preparations and dispose the dyeing
solutions down the drain but not into a sink.










2. Permanent Mount

Wipe the slide and cover glass clean.
Continue as above but before covering the
slide with the cover glass, add few drops of
gum media (or Canada balsam) solution or
transparent adhesive glue with a dissecting
needle to the slide.
Place the cover glass on top with tweezers,
and leave it to dry for about a day.


Safety Recommendations:

Always seek medical attention in case of any
doubts.

In case of:
Eye contact: Wash the eye with plenty of
water, and if necessary hold the eye open.
Inhalation: Remove person to fresh air.
Cut: The wound should be washed in
antiseptic solution, or clean water. Next, put
on a bandage.
Swallowed: Do not encourage vomiting.
Wash mouth with water, and drink fresh water.
In any of the above situations, please contact a
doctor.



IMPORTANT: Keep these
instructions. DO NOT
DISCARD.


1. Requires 2 x AA (LR6) batteries. (Not
included)
2. Only adults should install and replace batteries.
3. Alkaline batteries are recommended.
4. Do not use rechargeable batteries.
5. If the toy has not been used for a long time,
remove the batteries.
6. Non-rechargeable batteries are not to be
recharged.
7. Do not mix old and new batteries.
8. Do not mix alkaline, standard (carbon zinc) or
rechargeable (nickel cadmium) batteries.
9. Exhausted batteries are to be removed from
the toy.
10. The supply terminals are not to be
short-circuited.
11. Only batteries of the same or equivalent type
as recommended are to be used.
12. Batteries are to be inserted with the correct
polarity.
































INSTRUCTION MANUAL
4 IN 1 Petit E. Microscope
WARNING! Only for use by children over 8 years old. Only for use under
the supervision of adult. This toy contains functional edge.

CAUTION! Read the instructions before use, follow them and keep them
for reference. Keep small children and animals away from
experiments. Store the microscope set out of reach of small
children. Eye protection for supervising adults is not included.
All rights reserved. Copyright 2008 Eastcolight (Hong Kong) Ltd.



























INSTRUCTION MANUAL
New Generation Digital Microscope
WARNING! Only for use by children over 8 years old. Only for use under
the supervision of adult. This experiment kit contains functional
sharp needle, also functional sharp edge on scalpel.

CAUTION! Read the instructions before use, follow them and keep them
for reference. Keep small children and animals away from
experiments. Store the microscope set out of reach of small
children. Eye protection for supervising adults is not included.
All rights reserved. Copyright 2006 Eastcolight (Hong Kong) Ltd.
Rev. 2.0
Parent Quick Start Guide

While the New Generation Microscope is easy to install and use, the initial
hardware and software setup must be done by an adult. Please follow
the instructions below to get started.

It is important to install the software first. This microscope will work on
computers equipped with a USB 1.1 port (USB 2.0 recommended) and
Windows2000, WindowsXP SP2 or WindowsVista. Driver
installation for Windows2000 system is mandatory. Driver installation
for XP SP2 and Vista systems is optional and only required if your
computer has issues using this microscope in driverless mode.

1. Insert the installation CD.

2. Wait for the autoplay to start.
(If Autoplay does not automatically launch the installer, go to the
desktop and double-click on the icon named My Computer.
Double-click the icon for the CD-ROM/DVD drive that contains the E.
Microscope software. Sometimes this will cause Autoplay to start. If
it doesnt, double-click on the autorun.exe, and follow the setup
steps on this page.)

3. This step is optional for Windows XP SP2 and Vista users, you do
not need to install driver. You can jump to step 4. However, you can
install driver if you really want to. For Windows 2000 users, you
must install driver first: Connect the microscopes USB plug to the
USB port of the computer. Install the microscope driver by clicking
Install Driver. Follow the on screen instructions to complete the
installation.

4. Install the ArcSoft camera suite by clicking Install PhotoImpression
and Install VideoImpression on the menu screen. Input the license
key found on the CD sleeve if prompted.

5. Follow the steps by clicking the appropriate buttons.

6. You need the Adobe Acrobat Reader software to open the manual.
Click Install Adobe Acrobat Reader if your computer does not have
this software.
7. If you have the Adobe Acrobat Reader software installed, you can
read the manuals for the Digital Microscope and the camera suite by
clicking Microscope Manual and ArcSoft Application Software
Manual on the menu screen respectively.

8. Insert the microscopes USB plug to the USB port of the computer. A
new device named USB 2.0 Camera will be detected on the first
time the microscope is plugged in. Start the PhotoImpression or
VideoImpression application to acquire image with the digital
microscope.



Under the environment with electrostatic discharge, the device
may malfunction and require user to reset the device.


- i -
- ii -
Package contents:
1. 1 Digital Microscope
2. 5 objective lenses (100x, 300x, 450x, 600x, 900x)
3. 1 lens holder
4. 1 magnifier
5. 2 prepared slides
6. 10 blank slides
7. 36 blank labels
8. 36 slide covers
9. 36 cover glasses
10. 2 collecting vials
11. 1 pair of metal tweezers
12. 1 dissecting needle
13. 1 stirring rod
14. 1 scalpel
15. 1 pipette
16. 1 screwdriver
17. 1 Software CDROM
18. This manual

Minimum system requirements:
A computer with USB port
Intel Pentium 4 Processor or AMD Athlon XP or faster
256MB System RAM
Windows 2000/XP SP2/ Windows Vista
CD-ROM drive
16-bit color display or higher

Software setup guide
For Windows 2000 users, please install the microscope driver software first.
However, for Windows XP SP2 or Vista users, this digital microscope does not
require any driver installation. Driver installation for XP SP2 and Vista systems
is optional and only required if your computer has issues using this
microscope in driverless mode. In any case, you need to use an imaging and/or
a video application software to capture the images from the digital microscope.
You can use your favorite application or the ones provided on the software
CDROM:
1. Insert the software CDROM to your CDROM drive
2. Wait for autoplay to start
3. If the installer screen does not come up automatically, click Start, Run,
and execute the file autorun.exe of the CD to start the installation program.
4. This step is optional for Windows XP SP2 and Vista users, you do not need
to install driver. You can jump to step 5. However, you can install driver if you
really want to. For Windows 2000 users, you must install driver first:
Connect the microscopes USB plug to the USB port of the computer. Install
the microscope driver by clicking Install Driver. Follow the on screen
instructions to complete the installation.
5. Install ArcSoft Camera Suite by clicking Install PhotoImpression and
Install VideoImpression on the installer screen. Input the license key found
on the CD sleeve if prompted.

Connecting the Digital Microscope:
1. After the Digital Microscope software has been installed, plug the
microscopes USB cable into your computers USB port.
2. Go to the Windows Start menu to launch the imaging software like Arcsoft
PhotoImpression, for example.
Note:
For the location of the USB ports on your computer, please refer to your
computers user manual. To ensure that the digital microscope works normally, do
not connect or disconnect the USB cable from the computer while system is
starting up or shutting down. To avoid unstable system software functioning, do not
connect or disconnect the USB cable while application is opening or closing.
If you want to disconnect the digital microscope when the computer is on,
remember to:
1. Close any software application that currently using for the microscope.
2. Disconnect the USB cable.

Never pull on the cable portion to disconnect the USB cable, always grasp the
connector itself while disconnecting.
Note that the computer may not be able to recognize the microscope if it is
disconnected and then reconnected while the computer is in power saving mode.

















- 2 -
- 1 -
Name of Parts:
1. Microscope Head
2. Focus Knob
3. Illumination Switch
4. Illumination Light
5. Battery Compartment
6. Clips
7. Lens Holder
8. Objective Lens
1
2
3
4
6
7
8
5
8
Welcome to the world of
Micro-Science



We take great pleasure in introducing you to the
world of Microscope. Microscope refers to an
instrument with lenses for making very small
near objects to appear larger. Because there
are innumerable living things that cannot be
seen with our naked eyes, microscope enables
these invisible living things to be seen
effortlessly.

The discovery of microscope goes back many
many years, and since the invention it has
exposed to a new field of exploration and study
as more attractive, and exquisite specimens as
you ever imagined can be evidenced.

In our new world of advanced technology, every
science from the most fundamental study of
biology to the highly skilled fields of
astro-physiology will use some form of
microscope. The mission of microscope
allows anyone from all walks of life to better
comprehend the complex forms of living
organisms or stagnant materials that construct
this world which we live in.

This microscope set will be the starting point to
your many hours of fruition as a hobby or
broader your opportunity to a wonderful world of
science.

Happy Experimenting!!!

Attention

The following information should be read carefully
in order to overcome confusions.

This microscope set is appropriate for children over
8 years old. If not applied, supervision of adult is
required as this set comprises of functional sharp
edge.

Before using the microscope, attentively and
carefully read the instructions, follow the guide, and
keep them for future direction in case you need
further helpful hints.

In any situation, be extremely cautious not to allow
chemicals to come into contact with any part of the
body, especially the eyes and mouth. Keep away
young infants and animals from the experiment.
Always, keep the microscope set in a place where
young infant is out of reach.

Eye protection is not provided, it can be obtained
from any science departments, and major shopping
outlets. Remember, in case of accidents please
seek medical advice.

Helpful Hints

The essential component of the microscope is
the lens. Consequently, adequate care must
be exercised when dealing with the lens.
Microscope should be stored in a moisture
free place. Because moisture build up on the
lenses will reduce the light intensity.
After it is utilized, protect the microscope from
dust by covering the microscope or putting it
back into the box.
If the lens gets dusty or dirty, it is suggested to
clear off the lens surface with a soft cotton
cloth or tissue. Do not rub the lens with a
finger or unclean cloth.
If a microscope is not used for a long period of
time, discharge the light source batteries.

Always keep instructions to hand.







































How To Make a Prepared Slide

Please note that if the given specimen is not thin
and crystalline, it cannot be inspected by the
microscope. This is due to the fact that light from
the reflector or light source does not advance
through.

Fibres of wool, pollen, or salt will be simple to
see, and will not need a cover glass.
Crystal-clear specimen are stain first with a
drop or two drops of methylene blue. Eosin
or other dyeing solutions are available on the
market.

Also note these are dyeing solutions, and thus
could induce staining of clothing, fabrics, and
carpets. Extreme care should be handled with
when dealing with these solutions.



1. Temporary Mount

Wipe the slide and cover glass clean
Thin the sample with a razor blade. (Be
extremely careful)
Then pick it up with tweezers, and put it on the
centre part of the glass slide.
Next, add one drop of water on the sample
with a dissecting needle. If the sample is
clear, add one drop of methylene blue or eosin
solutions. (Be extremely careful)
Gently put the cover glass on top of it, be sure
not to let any air bubbles go in.
Remove any excess water or dyeing solutions
with blotting paper.
Now, it is ready for observation.

Remember to wash your hands immediately after
doing the preparations and dispose the dyeing
solutions down the drain but not into a sink.










2. Permanent Mount

Wipe the slide and cover glass clean.
Continue as above but before covering the
slide with the cover glass, add few drops of
gum media (or Canada balsam) solution or
transparent adhesive glue with a dissecting
needle to the slide.
Place the cover glass on top with tweezers,
and leave it to dry for about a day.


Safety Recommendations:

Always seek medical attention in case of any
doubts.

In case of:
Eye contact: Wash the eye with plenty of
water, and if necessary hold the eye open.
Inhalation: Remove person to fresh air.
Cut: The wound should be washed in
antiseptic solution, or clean water. Next, put
on a bandage.
Swallowed: Do not encourage vomiting.
Wash mouth with water, and drink fresh water.
In any of the above situations, please contact a
doctor.



IMPORTANT: Keep these
instructions. DO NOT
DISCARD.


1. Requires 2 x AA (LR6) batteries. (Not
included)
2. Only adults should install and replace batteries.
3. Alkaline batteries are recommended.
4. Do not use rechargeable batteries.
5. If the toy has not been used for a long time,
remove the batteries.
6. Non-rechargeable batteries are not to be
recharged.
7. Do not mix old and new batteries.
8. Do not mix alkaline, standard (carbon zinc) or
rechargeable (nickel cadmium) batteries.
9. Exhausted batteries are to be removed from
the toy.
10. The supply terminals are not to be
short-circuited.
11. Only batteries of the same or equivalent type
as recommended are to be used.
12. Batteries are to be inserted with the correct
polarity.





- 3 -
- 4 -
Battery Installation:

Use a screwdriver to open the battery compartment (5) on the bottom of the
microscope, install two AA size batteries (not included) according to the polarity
indicated. Replace the battery cover and tighten the screw.















Install the Objective Lens:

Select the objective lens with desired magnification power and remove the
protective cap. With the lens end pointing downwards, insert it to the opening at
the lower part of microscope head (1), as shown in the figure below. Push the
lens upwards until you feel a click. You need to hold the microscope head firmly
with the other hand to prevent it from moving.

To change lens, first
remove the installed
lens by pulling it
downwards, you may
need to use a little force.
Follow the same
procedure to insert
another objective lens.







Using the Digital Microscope:

1. Make sure the microscope is connected to the USB port of the computer.

2. Place the slide on the stage, fasten it in place with the clip(6) and switch
on the illumination.

3. Start PhotoImpression program from the Windows Start menu. The
application will start with the Get Photo screen. Here you can select the
device which you get your photo from. If you have correctly connected the
Digital Microscope, you should be able to select the Video icon. (On
some systems, the Video icon may not be selectable. In such case, get
photo from Camera/Scanner and then select WIA-USB Video Device.)






























- 5 -
- 6 -
4. A window Capture Image from Video will pop up, select USB 2.0
Camera from the Drivers list.



















5. The image window will be blank. To preview the image from the
microscope, click the Live button.




















6. Set the image size to 640x480
in the properties window by
clicking the Format button,
smaller image size (e.g.
352x288) is recommended for
slower computers.
















7. If there is flickering in the preview
image, click the Source button.
Try selecting different PowerLine
Frequency (Anti Flicker) setting in
the Properties window until
flickering is reduced.
















- 7 -
- 8 -
8. Focus:
Adjust the focus knob (2) until the image on the computer screen looks
clear. Focusing may take a little practice. Try making small changes and
waiting for the screen to catch up.

Selecting different magnification:
You can choose different magnification power by changing the objective
lens. Refer to the steps in the section Install the objective lens.

9. Press the Capture button to capture the current image. Press Done to
exit the Capture window.

































10. The captured image will appear in the main working area, select the
Enhance or Create icon near the top to edit the new image, or select
Get Photo again to capture another image. Refer to the manual of
PhotoImpression (in the supplied installation disc) for further details.




















Technical Specifications:

Image Sensor: 1/4.5 inch color CMOS (310k effective pixels)
Color: 24 bit RGB
Interface: USB 2.0 (backward compatible with version 1.1)
Video Preview: 30fps @320x240 pixels (QVGA)
30fps @640x480 pixels (VGA)
Video Control: PC software provides control for brightness, contrast,
hue, saturation, sharpness, gamma, 50/60Hz flicker
filtering
Video Capture: 30fps @320x240 pixels (QVGA)
30fps @640x480 pixels (VGA)
Still Capture: 30fps @320x240 pixels (QVGA)
30fps @640x480 pixels (VGA)
Magnification: 100, 300, 450, 600, 900 (for 15 screen)




- 10 -
- 9 -

I NSTRUCTI ON MANUAL
4 IN 1 PC LINK E. MICROSCOPE



















Copyright 2008 Eastcolight (Hong Kong) Ltd. All rights reserved.
Parent Quick Start Guide (E Microscope)

While 4 in 1 E. Microscope is easy to install and use, the initial hardware
and software setup must be done by an adult. Please follow the
instructions below to get started.

It is important to install the software first. This microscope will work on
computers equipped with a USB 1.1 port (USB 2.0 recommended) and
Windows2000, WindowsXP SP2 or WindowsVista. Driver
installation for Windows2000 system is mandatory. Driver installation
for XP SP2 and Vista systems is optional and only required if your
computer has issues using this microscope in driverless mode.

1. Insert the installation CD.

2. Wait for the autoplay to start.
(If Autoplay does not automatically launch the installer, go to the
desktop and double-click on the icon named My Computer.
Double-click the icon for the CD-ROM/DVD drive that contains the E.
Microscope software. Sometimes this will cause Autoplay to start. If
it doesnt, double-click on the autorun.exe, and follow the setup
steps on this page.)

3. This step is optional for Windows XP SP2 and Vista users, you do
not need to install driver. You can jump to step 4. However, you can
install driver if you really want to. For Windows 2000 users, you
must install driver first: Connect the microscopes USB plug to the
USB port of the computer. Install the microscope driver by clicking
Install Driver. Follow the on screen instructions to complete the
installation.

4. Install the ArcSoft camera suite by clicking Install PhotoImpression
and Install VideoImpression on the menu screen. Input the license
key found on the CD sleeve if prompted.

5. Follow the steps by clicking the appropriate buttons.

6. You need the Adobe Acrobat Reader software to open the manual.
Click Install Adobe Acrobat Reader if your computer does not have
this software.
7. If you have the Adobe Acrobat Reader software installed, you can
read the manuals for the Digital Microscope and the camera suite by
clicking Microscope Manual and ArcSoft Application Software
Manual on the menu screen respectively.

8. Insert the microscopes USB plug to the USB port of the computer. A
new device named USB 2.0 Camera will be detected on the first
time the microscope is plugged in. Start the PhotoImpression or
VideoImpression application to acquire image with the digital
microscope.



Under the environment with electrostatic discharge, the device
may malfunction and require user to reset the device.


- ii -
- i -
Package contents:
1. Microscope
2. Digital camera (with lens, USB cable and stand)
3. Eyepiece.
4. 2 prepared slides
5. 10 blank slides
6. 12 blank labels
7. 12 slide covers
8. 12 cover glasses
9. Software CDROM
10. This manual

Minimum system requirements:
A computer with USB port
Intel Pentium 4 Processor or AMD Athlon XP or faster
256MB System RAM
Windows 2000/XP SP2/ Windows Vista
CD-ROM drive
16-bit color display or higher

Software setup guide
For Windows 2000 users, please install the microscope driver software first.
However, for Windows XP SP2 or Vista users, this digital microscope does not
require any driver installation. Driver installation for XP SP2 and Vista systems
is optional and only required if your computer has issues using this
microscope in driverless mode. In any case, you need to use an imaging and/or
a video application software to capture the images from the digital microscope.
You can use your favorite application or the ones provided on the software
CDROM:
1. Insert the software CDROM to your CDROM drive
2. Wait for autoplay to start
3. If the installer screen does not come up automatically, click Start, Run,
and execute the file autorun.exe of the CD to start the installation program.
4. This step is optional for Windows XP SP2 and Vista users, you do not need
to install driver. You can jump to step 5. However, you can install driver if you
really want to. For Windows 2000 users, you must install driver first:
Connect the microscopes USB plug to the USB port of the computer. Install
the microscope driver by clicking Install Driver. Follow the on screen
instructions to complete the installation.
5. Install ArcSoft Camera Suite by clicking Install PhotoImpression and
Install VideoImpression on the installer screen. Input the license key found
on the CD sleeve if prompted.

Connecting the Digital Microscope:
1. After the Digital Microscope software has been installed, plug the
microscopes USB cable into your computers USB port.
2. Go to the Windows Start menu to launch the imaging software like Arcsoft
PhotoImpression, for example.
Note:
For the location of the USB ports on your computer, please refer to your
computers user manual. To ensure that the digital microscope works normally, do
not connect or disconnect the USB cable from the computer while system is
starting up or shutting down. To avoid unstable system software functioning, do not
connect or disconnect the USB cable while application is opening or closing.

If you want to disconnect the digital microscope when the computer is on,
remember to:
1. Close any software application that currently using for the microscope.
2. Disconnect the USB cable.

Never pull on the cable portion to disconnect the USB cable, always grasp the
connector itself while disconnecting.
Note that the computer may not be able to recognize the microscope if it is
disconnected and then reconnected while the computer is in power saving mode.

Using the Microscope in Digital Mode:




















- 2 -
- 1 -
1. If you have been using the digital camera module as a web camera,
unscrew the objective lens unit from the camera (figure 2). The eyepiece on
the microscope also needs to be removed.
















Figure 2


2. Snap the digital camera module in the eyepiece position (Figure 3), make
sure the camera module sits properly in place.













Figure 3


3. Make sure the microscope is connected to the USB port of the computer.

- 3 -
4. Install two AA size batteries (not included) in the battery compartment at the
base of the microscope. Place the slide on the sample platform and turn on
the light source, the bottom light source is recommended if using
transparent slide.

5. Start PhotoImpression program from the Windows Start menu. The
application will start with the Get Photo screen. Here you can select the
device which you get your photo from. If you have correctly connected the
Digital Microscope, you should be able to select the Video icon. (On some
systems, the Video icon may not be selectable. In such case, get photo
from Camera/Scanner and then select WIA-USB Video Device.)































- 4 -
6. A window Capture Image from Video will pop up, select USB 2.0 Camera
from the Drivers list.



















7. The image window will be blank. To preview the image from the microscope,
click the Live button.




















8. Set the image size to 640x480 in
the properties window by clicking
the Format button, smaller
image size (e.g. 352x288) is
recommended for slower
computers.
















9. If there is flickering in the preview
image, click the Source button. Try
selecting different PowerLine
Frequency (Anti Flicker) setting in
the Properties window until
flickering is reduced.















- 5 -
- 6 -
10. Focus:
Adjust the focus knob until the image on the computer screen looks clear.
Focusing may take a little practice. Try making small changes and waiting
for the screen to catch up.

Selecting different magnification:
You can choose different level by rotating the magnification ring on the
microscope. The current level is indicated on the magnification level label
facing you. You will feel a click if the lens is properly aligned. Levels of 100X,
200X and 300X can be selected.

11. Press the Capture button to capture the current image. Press Done to
exit the Capture window.






























12. The captured image will appear in the main working area, select the
Enhance or Create icon near the top to edit the new image, or select Get
Photo again to capture another image. Refer to the manual of
PhotoImpression (in the supplied installation disc) for further details.



















Using the Microscope in non-Digital Mode:

1. Replace the digital camera module of the microscope with the removable
eyepiece for direct viewing (figure 4).













Figure 4

- 8 -

- 7 -
2. Focusing and magnification level selection are the same as in digital mode.

3. Please refer to the detail instructions of using the microscope starting from
page 11.

Using the digital camera module as a PC camera:

1. Screw the objective lens unit back to the camera module if it has been
removed for microscope viewing. Care should be taken not to make
fingerprints or dust on the lens and the sensor of the camera.

2. The camera stand comes in two separate pieces, connect them together as
shown in the following picture. Make sure the top part is secured into the
base. Push downwards to connect the joint together.













3. Place the camera unit on the stand as shown below.














- 9 -
4. Connect the camera module to the USB port of the computer
5. Start PhotoImpression or other Imaging applications from the Windows
Start menu.
6. Adjust the focus by rotating the lens until a clear image is displayed.
7. You can take still pictures and save them in the computer using the same
procedure as described in the section Using the Microscope in Digital
Mode.
8. To use the camera module as a web camera for video conference, you need
to install applications like Netmeeting or MSN Messenger, which can be
downloaded from Microsofts web site. Please refer to the corresponding
application manual.

Handling note:

The image sensor of the camera is a delicate integrated circuit and must be
handled carefully. When you remove the lens from the camera, dust may fall on
the sensor. Only use a blower to clean the dust. Never touch the sensor.

Technical Specifications:

Image Sensor: 1/4.5 inch color CMOS (310k effective pixels)
Color: 24 bit RGB
Interface: USB 2.0 (backward compatible with version 1.1)
Video Preview: 30fps @320x240 pixels (QVGA)
30fps @640x480 pixels (VGA)
Video Control: PC software provides control for brightness, contrast,
hue, saturation, sharpness, gamma, 50/60Hz flicker
filtering
Video Capture: 30fps @320x240 pixels (QVGA)
30fps @640x480 pixels (VGA)
Still Capture: 30fps @320x240 pixels (QVGA)
30fps @640x480 pixels (VGA)
Magnification: 100, 200, 300 (for 14 screen)









- 10 -
Welcome to the world of
Micro-Science



We take great pleasure in introducing you to the world of Microscope.
Microscope refers to an instrument with lenses for making very small near
objects to appear larger. Because there are innumerable of living things that
cannot be seen with our naked eyes, microscope enables these invisible living
things to be seen effortlessly.

The discovery of microscope goes back many many years, and since the
invention it has exposed to a new field of exploration and study as more
attractive, and exquisite specimens as you ever imagined can be evidence.

In our new world of advanced technology, every science from the most
fundamental study of biology to the highly skilled fields of astro-physiology will
use some form of microscope. The mission of microscope allows anyone
from all walks of life to better comprehend the complexity forms of living
organisms or stagnant materials that construct this world in which we live in.

This microscope set will be the starting point to your many hours of fruition as a
hobby or broader your opportunity to a wonderful world of science.

Happy Experimenting!!!

Attention

The following information should be read carefully in order to overcome
confusions.

This microscope set is appropriate for children over 8 years old. If not applied,
supervision of adult is required as this set comprises of functional sharp edge.

Before using the microscope, attentively and carefully read the instructions, follow
the guide, and have them for direction in case you need further helpful hints.

In any situation, be extreme caution to not allow chemicals to come into contact
with any part of the body, especially the eyes and mouth. Keep away young
infants and animals from the experiment. Always, reserve the microscope set in
a place where young infant is out of reach.

Eye protection is not provided, it can be obtained from any science departments,
and major shopping outlets. Remember, in case of accidents please seek
medical advice.








- 11 -
Helpful Hints

The essential component of the microscope is the lens. Consequently,
adequate care must be exercised when dealing with the lens.
It is important to put the removable eyepiece at position 1 (see picture below)
for viewing without the camera module.
Microscope should be stored in a moisture free place. Because moisture
build up on the light encourages a reduction in light concentration.
After it is utilized, protect the microscope from dust by covering the
microscope or placing it back into the box.
If the lens gets dusty or dirty, it is suggested to clear off the lens surface with a
soft cotton cloth or tissue. Do not rub the lens with a finger or unclean cloth.
If a microscope is not put to use for a long period of time, discharge the light
source batteries.

Always keep instructions to hand.


Components of a Microscope

1. Eyepiece (removable)
2. Focusing knob
3. Body tube
4. Objective lens
5. Arm
6. Stage
7. Clip
8. Clip adjustors
9. Non-transparency illuminator
10. Power switches for the illuminators
11. Base
12. Magnification revolving turret
























- 12 -
12
1
2
3
4
6
7
8
9
5
11
10
Procedures

1. Firstly, insert 2 AA penlite dry cells batteries in the back of the base. You will
need to use a screwdriver to open the base. (Batteries are not included)






















2. Now put the prepared slide on the stage, and fasten it in place with the clip
adjustors.












3. Next, choose the magnification strength you desire. In general, it is
recommended to begin with lower magnification for easier focusing. To
change the magnification setting, turn the magnification revolving turret until
you hear a click.












- 13 -
4. Choose the illuminator for viewing. If an object is thin and crystalline, or when
light can advance through the object, use the transparency illuminator. For an
object which light does not advance through, use the non-transparency
illuminator.












5. Look through the eyepiece and slowly adjust the focusing knob until the object
on the slide becomes clear. To view different part of the slide, adjust the clip
adjustors until the desired object appears through the eyepiece.





















How To Make a Prepared Slide

Please note that if the given specimen is not thin and crystalline, it cannot be
inspected by the microscope. This is due to the fact that light from the reflector or
light source does not advance through.

Fibres of wool, pollen, or salt will be simple to see, and will not need a cover
glass.
Crystal-clear specimen are stain first with a drop or two drops of methylene
blue. Eosin or other dyeing solutions are available on the market.

Also note these are dyeing solutions, and thus could induce staining of clothing,
fabrics, and carpets. Extreme care should be handled when dealing with these
solutions.


- 14 -
1. Only adults should install and replace
batteries and bulb.
2. Alkaline batteries are recommended.
3. Do not use rechargeable batteries.
4. Non-rechargeable batteries are not to be
recharged.
5. If the toy has not used for a long time, remove
the batteries.
6. Do not mix old and new batteries.
7. Do not mix alkaline, standard (carbon zinc) or
rechargeable (nickel-cadmium) batteries.
8. Exhausted batteries are to be removed from
the toy.
9. The supply terminals are not to be
short-circuited.
10. Only batteries of the same or equivalent type
as recommended are to be used.
11. Batteries are to be inserted with the correct
polarity.
12. Do not dispose of batteries in fire, batteries
may explode or leak.
13. Batteries may explode or leak if misused.
1. Temporary Mount

Wipe the slide and cover glass clean
Thin the sample with a razor blade. (Be extremely careful)
Then pick it up with tweezers, and put it on the centre part of the glass slide.
Next, add one drop of water on the sample with a dissecting needle. If the
sample is clear, add one drop of methylene blue or eosin solutions. (Be
extremely careful)
Gently put the cover glass on it, take care not to let any air bubbles in it.
Remove any excess water or dyeing solutions with blotting paper.
Now, it is ready for observation.

Remember to wash your hands immediately after doing the preparations and
dispose the dyeing solutions down the drain not into a sink.











2. Permanent Mount

Wipe the slide and cover glass clean.
Continue as above but before covering the slide with the cover glass, add few
drops of gum media (or Canada balsam) solution or transparent adhesive
glue with a dissecting needle to the slide.
Put down on the cover glass with tweezers or fix it in place, and leave it to dry
for about a day.


Replacing Light Bulb















- 15 -
Changing the Non-Transparency Illuminator light bulb
1. The microscope uses a 3V, 0.2A, TL-3 type light bulb.
2. Pull the back of the Non-Transparency Illuminator until the session comes out.
3. Remove the old light bulb by turning it anti-clockwise.
4. Put the new light bulb in place by turning it clockwise.
5. Put the session back into the illuminator.












Safety Recommendations:

Always seek medical attention in case of any doubts.

In case of:
Eye contact: Wash out eye with plenty of water, and if necessary holding
eye open.
Inhalation: Remove person to fresh air.
Cut: Cut should be washed in antiseptic solution, or clean water. Next step
is to put on a bandage.
Swallowed: Do not encourage vomiting. Wash out mouth with water, and
drink fresh water.

In any of the above situations, please contact a doctor.


IMPORTANT: Keep these instructions. DO NOT DISCARD.





















- END -
Caution: Light bulb could be hot after using. Do not change
light bulb immediately after using the microscope. Turn off all
power before changing light bulb.
WARNING! Only for use by children over 8 years old. Only for use under
the supervision of adult. This toy contains functional edge.

CAUTION! Read the instructions before use, follow them and keep
them for reference. Keep small children and animals away
from experiments. Store the microscope set out of reach of
small children. Eye protection for supervising adults is not
included.

You might also like