0% found this document useful (0 votes)
180 views1 page

Machine Foundation Irrigation Pump 1762001 559

This document summarizes the design of a machine foundation to check that the natural frequency of the foundation soil system and the operating frequency of the machine meet requirements. It provides the parameters of the concrete foundation and soil properties. Using Barkan's formula, it calculates the natural frequency and compares it to the operating frequency of the pump. It determines that the ratio of operating to natural frequency is 0.386, which is less than 0.5 and the calculated amplitude of 1.5606 mm is less than the permissible limit of 2.5 mm. It concludes that the foundation design is safe in vibration as the amplitude is within limits and resonance will not occur.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
180 views1 page

Machine Foundation Irrigation Pump 1762001 559

This document summarizes the design of a machine foundation to check that the natural frequency of the foundation soil system and the operating frequency of the machine meet requirements. It provides the parameters of the concrete foundation and soil properties. Using Barkan's formula, it calculates the natural frequency and compares it to the operating frequency of the pump. It determines that the ratio of operating to natural frequency is 0.386, which is less than 0.5 and the calculated amplitude of 1.5606 mm is less than the permissible limit of 2.5 mm. It concludes that the foundation design is safe in vibration as the amplitude is within limits and resonance will not occur.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

Soft Solution

Machine Foundation
Equipment Base
1 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
A B C D E F G H I J K L M N O P Q
ISBN 81-901030-7-5 Addendum to STQ 1503 NavigationIrrigation Pump Shed- Pump foundation
Machine Foundation - Design - Natural frequency of foundation soil system & amplitude check
References Barkan's formula to determine value of Az Cycles (f)/m v/s amplitude curves RPM in cycles amplitude in mm
Foundation parameters & v n 2.5 mm for 2900 rpm 2900 Az
Length Breadth Depth Concrete Foundation weight Machine m' EUCS Natural Frequency Operating Frequency OF/NF Soil density Amplitude
L B D Density Concrete Soil weight Mass(Total) cu cu*A v n v m h g Po Az
m m m kg/m^3 kg kg kg kg kg/m^2 (cu*A/m)^1/2 Manfacturer's datasheet # kg/cm^3 kgmf mm Method
1.6 1.6 0.35 2500 2240 358.4 990 365.79 7680 19661 7.331362139 2.83 0.386 1.6 2611.1 1.560622 1
m^3 0.896 Pump 395 by equation 1.0855 27788 8.715972306 2.83 0.3247 1.6 2611.1 1.050376 2
Pump 395 [cu=1.13-E/(1-m ^2) /a^.5] Reference Cycles(f )/m v/s amplitude curves mm
cu' determined by both methods Method Vessel 100 Permissible amplitude 2.5
By' Elastic-Area' equation 1 Frame 100 Since' foundation soil system' amplitude is within limits, the foundation is safe in vibration
By 'soil bearing' table consideration 2
Sand Silt General principle
Soil E m m Coefficient A Cu [cu=1.13-E/(1-m ^2) /a^.5] Wherever possible, the operating frequency should be
Kg/cm^2 poisson's ratio poisson's ratio in equation cm^2 Kg/cm^2 lower than the natural frequency of the foundation soil
2000 0.35 0.4 1.13 25600 1.085484 system & preferably within ratio 0.5
L Foundation length m otherwise it should be more than 2
B Foundation breadth m In this case the ratio is 0.386 0.324691
D Foundation depth m
cu Soil elastic uniform compression coefficient for 10 m^2 foundation area 3 to 5 Kg/cm^2 Comparison
A Foundation area m^2 Frequency ratio Amplitude
v n Natural frequency of foundation soil system vibration Permisible Permisible
v m Operating frequency of machine vibration 0.5 2.5
h Operating frequency of machine vibration/Natural frequency of foundation soil system vibration Provided Provided
g Soil density kg/cm^3 0.386012851 1.5606 1.050376
Po Exciting force produced vertically on machine kgmf Resonance shall not occur
Az Amplitude mm Design satisfies both conditions `
m Poisson's ratio
E Young's modulus of elasticity of foundation soil Kg/cm^2
m Combined mass of soil, foundation & machine Kg