0% found this document useful (0 votes)
799 views2 pages

Heidenhain TNC 355: Ncnet 7.0 Settings

The document provides settings and connection instructions for transferring NC programs between a Heidenhain TNC 355 controller and a PC running NCnet 7.0 software. It includes parameters to set on the machine and PC, as well as details on machine identification, communication ports and folders, baud rate, and cable connections depending on whether the PC has a 9-pin or 25-pin serial port connector. Drip feed mode is noted to be unavailable for this controller.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
799 views2 pages

Heidenhain TNC 355: Ncnet 7.0 Settings

The document provides settings and connection instructions for transferring NC programs between a Heidenhain TNC 355 controller and a PC running NCnet 7.0 software. It includes parameters to set on the machine and PC, as well as details on machine identification, communication ports and folders, baud rate, and cable connections depending on whether the PC has a 9-pin or 25-pin serial port connector. Drip feed mode is noted to be unavailable for this controller.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Page 1 of 2

Heidenhain TNC 355


NCnet 7.0 settings

Set these parameters on the machine

MP232 = 0 (data transfer mode)
MP71 = 515 (character for program start and end)
MP222 = 104 (data format)


To set the controller in the Drip-feed mode
Drip feed is not available on this controller.

Set these parameters on the PC

Machine details

Machine name MCH-1
Control system Heidenhain
Machine ID 01
Communication Channel Serial Port
Port Number Any free COM port
Folder for PC to Machine transfer Transmit directory
Folder for Machine to PC transfer Receive directory
Baud rate 2400
Data bits 7
Parity Even
Stop bits 2
Handshake Hardware

General settings
Ignore this. Leave all data as it is.

Transmit settings

Wait period at start of transmission 10.00
Wait period after transmitting program 5.0
Size of transmit packet 0
Delay period after each packet 0
Wait for XON before transmitting program No
Transmit comments? Yes
Comment start character (
Comment end character )
Translation mode for CR Transmit as CR
Translation mode for LF Transmit as LF
Acknowledgement and error (Mode of transmission) Transmit descriptive message
ACK/ERR Message start text %1234G71G50
ACK/ERR Message start text M30
%1234G71G50
Filter Null Character Yes





Page 2 of 2
NC Program settings

Program start string
Program end string
Characters to transmit at start Number of Characters
Characters to transmit at start Number of Characters

Receive settings

Wait period before receiving program 45.0
Wait period after receiving program 5.0
Transmit XON before transmitting program No
Auto compare and save Yes
Acknowledgements and errors Transmit descriptive messages
Translation mode for CR Ignore
Translation mode for LF Save as CRLF
Ignore control characters other than CR-LF Yes
Save Program between Start Characters and End Characters No
Start Program reception after these characters are received
End Program reception after these characters are received

To set the PC in the Drip-feed mode
Drip feed is not available on this controller.

Cable connections

If the PC has 9 pin connector

Null modem Full Handshake
PC
9 pin
1
2
3
4
5
6
7
8
8
2
3
20
7
6
4
5
CNC
25 pin

PC
9 pin
1
2
3
4
5
6
7
8
8
2
3
6
7
20
5
4
CNC
25 pin


If the PC has 25 pin connector

Null modem Full Handshake
PC
25 pin
8
2
3
20
7
6
4
5
8
3
2
20
7
6
4
5
CNC
25 pin

PC
25 pin
8
2
3
20
7
6
4
5
8
3
2
6
7
20
5
4
CNC
25 pin