TE/C Series: Transient Voltage Surge Suppressor/SPD
The document provides information about the TE/C Series Transient Voltage Surge Suppressor/SPD from Advanced Protection Technologies, Inc. It is designed to protect against voltage surges and transients consistent with various industry standards. It has a 5 year warranty, high surge current capacity of 80kA/phase up to 150kA/phase depending on the model, and response time of less than 1/2 nanosecond. It is suitable for indoor and outdoor applications with an operating temperature range of -40°C to +60°C.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
93 views
TE/C Series: Transient Voltage Surge Suppressor/SPD
The document provides information about the TE/C Series Transient Voltage Surge Suppressor/SPD from Advanced Protection Technologies, Inc. It is designed to protect against voltage surges and transients consistent with various industry standards. It has a 5 year warranty, high surge current capacity of 80kA/phase up to 150kA/phase depending on the model, and response time of less than 1/2 nanosecond. It is suitable for indoor and outdoor applications with an operating temperature range of -40°C to +60°C.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
Advanced Protection Technologies, Inc.
, 14550 58th Street North, Clearwater, Florida 33760
727.535.6339 - Toll Free: 800.237.4567 - Fax: 727.539.8955 - www.apttvss.com 19 TE/C Series Transient Voltage Surge Suppressor/SPD Design Features Designed, Manufactured, & Tested consistent with: IEEE C62.41.1-2002, C62.41.2-2002, and C62.45-2002 ANSI/IEEE C62.41-1991 and C62.45-1992 NEMA LS-1 NEC 285.6 High Energy Parallel Design for Category C3 and C High Applications For External Mounting next to Switchgear, Motor Control Centers, or Panelboards Thermal Cutout Typical connection: #12 AWG Pre-wired at the Factory and 20A Breaker Solid State Bi-directional LEDs to Indicate Loss of Protection or Circuit Fully Operational Quality 5 Year Warranty Burn-in Tested Prior to Shipment Short Circuit Current Rating 200,000 rms Symmetrical Amperes (UL Listed) APTs Quality Management System is ISO 9001:2000 Certified Performance Specifications Surge Capacity L-N L-G 80kA/phase 40k 40k Standard 100kA/phase 50k 50k Optional *120kA/phase 60k 60k Optional *150kA/phase 75k 75k Optional (*See Voltage Options on Reverse) UL 1449 Second Edition Revision Listed (UL 1449 Rev 2.5 Listed) UL 1283 Fourth Edition Listed UL Listed to Canadian safety standards UL 1449 Listed 200kA SCCR 200KAIR Rated Fusing Less than Nanosecond Response Time 5000 Category C3 (C High) Impulses with <10% Drift Environmental Specifications Relative Humidity Range: 0 - 100% Suitable for Indoor and Outdoor Applications Operating Frequency: 47 - 400 Hz Operating Temperature: -40 o
C (-40 o F) to +60 o C (+140 o F) Standard Configuration NEMA 4X Non-Metallic Standard Enclosure Standard Size: 8 x 3 x 3 Weight: 4 Lbs. Meets Feb 2007 UL changes: UL 1449 Second Edition Revision (UL 1449 Rev 2.5) Advanced Protection Technologies, Inc., 14550 58th Street North, Clearwater, Florida 33760 727.535.6339 - Toll Free 800.237.4567 - Fax 727.539.8955 - www.apttvss.com 20 010609010J-C TE/(x)C/(zz) x = Voltage Code, zz = Options Ordering information for Optional Features should be appended to the model number and separated by a slash(/). Example: TE/2C/120/FM Available Options: /100 Module Option increases the surge current capacity from 80kA to 100kA/phase (Available on all Voltages) /120 Module Option increases the surge current capacity from 80kA to 120kA/phase (*Only applies to Voltages 1, 11, and 2) /150 Module Option increases the surge current capacity from 80kA to 150kA/phase (*Only applies to Voltages 1, 11, and 2) /NG Adds Neutral to Ground Gas Tube (40kA) (Not Available on Voltages 5, and 6) /FM Flush Mount Option replaces the standard surface mount /DC Dry Contacts monitor each phase providing a summary alarm /RI Remote Indicator Option provides a single LED that can be remotely installed to show Go/No-Go status /NF Noise Filter provides Sinewave Tracking /EMI/RFI Filtering up to -50dB from 100kHz to 100MHz l e d o M e g a t l o V e c i v r e S e g a t l o V d e s s e r p p u S 9 4 4 1 L U ) R V S ( g n i t a R L - L G - L N - L V O C M C 1 / E T e s a h P t i l p S 0 2 1 / V 0 4 2 0 0 4 0 0 4 0 0 7 0 5 1 C 1 1 / E T e s a h P e l g n i S V 0 2 1 0 0 4 0 0 4 0 5 1 C 2 1 / E T e s a h P e l g n i S V 0 4 2 0 0 8 0 0 8 5 7 2 C 2 / E T E Y W , e s a h P e e r h T V 0 2 1 / Y 8 0 2 0 0 4 0 0 4 0 0 7 0 5 1 C 3 / E T A T L E D , g e L - h g i H , e s a h P e e r h T V 0 2 1 / V 0 4 2 0 0 8 / 0 0 4 0 0 8 / 0 0 4 0 0 2 1 / 0 0 7 5 7 2 / 0 5 1 C 4 / E T E Y W , e s a h P e e r h T V 7 7 2 / Y 0 8 4 0 0 9 0 0 9 0 0 5 1 0 2 3 C 5 / E T A T L E D , e s a h P e e r h T V 0 8 4 0 0 5 1 0 0 8 1 5 7 5 C 6 / E T A T L E D , e s a h P e e r h T V 0 4 2 0 0 8 0 0 0 1 5 7 2 C 7 / E T E Y W , e s a h P e e r h T V 0 2 2 / Y 0 8 3 0 0 9 0 0 9 0 0 5 1 0 2 3