0% found this document useful (0 votes)
434 views1 page

Architectural Drawing

This document contains notes for a construction drawing of proposed renovations to a building. It specifies that all dimensions are to be taken from the written dimensions only, not scaled from drawings. The builder must verify all dimensions and levels before starting work. The owner is responsible for ensuring the structural design is suitable for soil conditions. The design details in the drawing are confidential and only to be used for the authorized purpose. It provides general notes about demolition, services, structural, landscaping, and compliance with relevant authorities' requirements.

Uploaded by

bookslover1
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
434 views1 page

Architectural Drawing

This document contains notes for a construction drawing of proposed renovations to a building. It specifies that all dimensions are to be taken from the written dimensions only, not scaled from drawings. The builder must verify all dimensions and levels before starting work. The owner is responsible for ensuring the structural design is suitable for soil conditions. The design details in the drawing are confidential and only to be used for the authorized purpose. It provides general notes about demolition, services, structural, landscaping, and compliance with relevant authorities' requirements.

Uploaded by

bookslover1
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

C

1. DO NOT SCALE FROM DRAWNGS. USE WRTTEN DMENSONS ONLY.


2. BULDER TO CHECK & VERFY ALL DMENSONS & LEVELS PROR TO
COMMENCEMENT OF WORK.
3. T S THE OWNERS RESPONSBLTY TO ENSURE THAT THE ENGNEER
HAS NVESTGATED SUBSOL CONDTONS & DESGNED ALL
STRUCTURAL ELEMENTS TO SUT.
4. THE DESGN & DETALS CONTANED ON THS DRAWNG S SUPPLED N
CONFDENCE & S NOT TO BE USED FOR ANY OTHER PURPOSE,
EXCEPT THATAUTHORSED BY DEANGELS TAYLORAND ASSOCATES
Drawing No.
WD05
Amend't
E
No. of sheets
Job No.
10099
Drawn:
B.T
ScaIe:
As shown @A1
Project:
Dwg Name:
Address:
Nominated Architect:
CAD File: Z:\2010\10099.Liverpool Council.Rose St\3.Design\3.3 WD\10099.WD.(D).Rose St.Liv Council.pln
I: 1 2 01 1011 f: 1 2 821 2213 w: www.cI c.neI .cu
8 8 L c I h u r : I : I r e e I | i v e r p c c | n : w 2 1 7 0 c u : I r c | i c
pc Lcx 8 | i ver pcc| Lc n: w 1871 e: ccmi n@ cI c.neI .cu
Issue Amendment
P1
Drwn Date Chk'd
07.06.2011 AB BA PRELMNARY SSUE
CIient: Project North:
LIVERPOOL
CITY
COUNCIL
STEPHEN TAYLOR.....................................................................................
NSWArchitects Registration Board No. 7414 5 of 13
or ch| t ect ur e | nt er | or des| gn ur bon des | gn
COPYRGHT 2010 - DE ANGELS TAYLOR + ASSOCATES PTY LTD
ROSE STREET DEPOT - FITOUT CONTRACT
ROSE STREET LIVERPOOL NSW 2170
PROPOSED GROUND FLOOR PLAN
14.02.12
Date:
P2 30.06.2011 AB BA PRELMNARY SSUE
A 11.08.2011 AB BA CONSTRUCTON SSUE
C 14.02.12 BT ST SSUED FOR TENDER
D 24.02.12 BT ST SSUED FOR TENDER
E 27.02.12 BT ST AMENDED FOR TENDER
d e o n g e I | s t o y I o r + o s s o c | o t e s
W07
D
0
2
D07
W05
D
1 4
D16
D15
W08
D10
W06
D08
D
1 1
D19
D12
D13
D17
D
2 3
D
2 1
W01
D01
D22
D09
7
WD13
2
WD10
3
WD10
2
WD12
13
14
15
16
17 18 19
20
21
22
23 24
25
26
27
28
29 30 31
32
33
34
35 36
1
2 3
4 5
6
7
9 8
11 10
12
W
0
3
W
0
4
W
0
2
30,860
270 4,425 90 3,778 230 12,915 230 1,802 90 3,050 90 3,620 270
270 8,293 230 12,915 230 1,802 90 1,990 90 1,080 90 1,600 90 1,820 270
270 23,470 90 1,990 90 1,040 90 3,550 270
2 2 , 4 6 0
4 , 0 0 0
2 7 0
5 , 4 1 0
9 0
3 , 1 1 0
9 0
5 , 0 0 0
9 0
3 , 1 2 0
9 0
1 , 5 5 0
1 , 3 4 0
9 0
1 , 9 4 0
2 7 0
2 7 0
5 , 4 1 0
9 0
3 , 1 1 0
9 0
5 , 0 0 0
9 0
5 6 0
2 , 5 6 0
9 0
4 , 9 2 0
2 7 0
30,860
270 4,425 3,485 90 22,320 270
2 7 0
5 , 4 1 0
9 0
3 , 1 1 0
9 0
3 , 5 5 0
2 , 0 1 0
9 0
1 , 0 0 0
2 , 6 9 0
9 0
1 , 2 5 0
9 0
2 , 4 5 0
2 7 0
270 4,425 90 18,955 90 7,030
4,700 3,810 22,350
270 4,425 19,045 90 6,760 270
1 , 5 0 0
1 , 6 0 0
2 7 0
8 , 4 7 0
9 0
7 , 4 9 0
9 0
5 , 7 8 0
2 7 0
2 7 0
3 , 5 8 0
1 , 2 0 0
9 0
3 , 6 0 0
9 0
3 , 7 0 0
9 0
3 , 6 9 0
1 0
9 0
5 , 7 8 0
2 7 0
2 7 0
1 , 2 0 0
9 0
2 0 , 6 3 0
2 7 0
4,700 230 3,350 230
3 0 0 0
1 , 2 0 0
1,200
1 , 2 0 0
9 0
270 7,725 90
95 90 325
90 21,905 270
1 , 5 0 0
1 , 6 0 0
2 , 0 0 0
20
1
WD08
1
WD08
2
WD08
2
WD08
3
WD08
3
WD08
4
WD08
4
WD08
Opaque film to be
fixed internaly
to exist. window panes
Opaque film to be
fixed internaly
to exist. window panes
New rainwater tank.
Refer to hydraulic eng's
details.
New rainwater tank.
Refer to hydraulic eng's
details.
Existing EDB
Provide 13mm plasterboard lining
on furring channels to all visible
external faces of the existing walls
of the server room
EXSTNG WNDOW
TO BE BRCKED UP
AND MADE GOOD
EXSTNG WNDOW
TO BE BRCKED UP
AND MADE GOOD
FemaIe
MaIe
Lunch Room
Ex. Server
Room
Meeting Room
Access
WC
Verandah
Entry
Open PIan Office
EXT
EXT
EXT
V
NS-CT
Ct
Corridor

V
84 Locker Change Room
waterless wall
hung urinals
shr shr shr shr shr
shr
shr
Lockers (2 tier)
L o c k e r s (2 t i e r)
L o c k e r s
B
e n c h
Bench
Rose Street
Ct
Ct
B B
F
a l l
CInr
B B B
(2 t i e r)
F
H
R
EXT
F
a l l
Ct
Break out
Room
B e n c h C
'p d
NS-CT
NS-CT
DP DP
Ct
Break out
Room
Photocopy/
Stationary Room
Ct
Lockers (2 tier)
B
e n c h
Ct
Emergency Room/
Meeting Room/
Hot Desk Room
BOOK SHELVES BOOK SHELVES BOOK SHELVES
E
X
T
EXT
E
X
T
D
0 3
D
0 4
D
0 5
D
0 6
R
E
F
.
Existing structural column.
Existing structural column.
ndicative office plan
layout. Loose
Furniture by others.
6
Locker
Change
Room
D
2 4
New entrance portal. Face brick walls,
timber framed roof, to eng's detail, with
ACM cladding. Refer to spec.
ndicative location of
proposed A/C units.
Provided recessed floor mat.
Vertical aluminium louvres attatched
to galvanised steel frame to eng.
details. With ACM clad steel frame
awning overhead to eng. details.
Vertical aluminium louvres attatched
to galvanised steel frame to eng.
details. With ACM clad steel frame
awning overhead to eng. details.
Proposed timber framed
awning overhead, to eng's
detail. Refer to roof plan.
ndicative location of proposed
seperate A/C unit for server room.
New reinforced concrete slab to eng's
detail.
Existing kerb.
ndicative Lunch Room layout.
Furniture provided by others
Top existing slab in amenities area to allow for CT
with sufficient falls to FW's. Allow to taper/fall FLR
finish in corridors to blend/match existing FLR level.
New reinforced concrete slab pathway
to eng's detail.
Existing structural column.
New bollards as specified
Existing face brick columns to remain
Provide 13mm plasterboard
lining on furring channels to all
visible external faces of the
existing walls of the lunch room
Provide sealed joint to gap /
cavity between new walls / slab
& the existing brick wall
Provide 13mm plasterboard
lining on furring channels to all
visible internal faces of the
existing walls.
Provide 13mm plasterboard
lining on furring channels to all
visible faces of brickwork in the
lunch room
Refer to Legend - Plan
for wall description.
Extent of new
slab under
Extent of new slab under.
To be confirmed.
Extent of new
slab under
Extent of new
slab under.
Operable wall
Extent of new
slab under
10 x Hot Desks
Lower sill and replace existing
windows with new aluminium
framed extruded windows - refer
to schedule for details
Lower sill and replace existing
windows with new aluminium
framed extruded windows - refer
to schedule for details
Provide new skylights over
GENERAL NOTES:
VERFY ON STE ALL SURVEY NFORMATON NCLUDNG ALL EXSTNG
SERVCES & LEVELS PROR TO CONSTRUCTON.
DEMOLSH EXTG STRUCTURES & CLEAR ALL VEGETATONAS REQURED
AND/OR AS SHOWN ON DRAWNGS, READY FOR NEWWORKS. DSPOSE OF
DEMOLSHED BULDNG MATERALSAND ASBESTOS MATERAL
ENCOUNTERED DURNG DEMOLTON, EXCEPT THOSE TEMS SPECFCALLY
DENTFED FOR REUSE.
TERMNATE, CAP OFF OR DVERT OF ALL EXSTNG SERVCES WHERE SO
REQURE AND/OR AS NECESSARY TO CARRY OUT NEW WORKS. PERFORM
ALL WORKS N BEST TRADESMAN-LKE MANNER AND TO THE SATSFACTON
OF RELEVANTAUTHORTES.
REFER TO STRUCTURAL ENG'S DOCUMENTS FOR DETALS OF CONC.
SLABS, STEPS, FOOTNGS NCLUDNG SZES OF STRUCTURAL MEMBERS.
ALL TMBER FRAMNG SZES SHALL COMPLYWTH THE TMBER FRAMNG
CODE.
COMPLYWTH LANDSCAPNG REQUREMENTS AS REQURED BY THE
COUNCL CONDTONS AND/OR AS DETALED BY LANDSCAPE ARCHTECT .
REFER TO HYDRAULC ENG'S DETALS FOR LOCATONAND LEVELS OF ALL
STORM WATERPTS. UNO. CONNECT ALL DOWNPPES NTO NEAREST
EXSTNG STORM WATERSYSTEM AS REQURED AND/OR TO HYD. ENG'S
DETALS. UNO. PROVDE FALL N GROUND FNSHES TO ENSURE ALL
STORM WATER FALLS AWAYFROM BULDNG. LAY PAVNGWTH
SUFFCENT FALL TO PT TOAVOD PONDNG.
REFER TO HYDRAULC ENG'S DETALS FOR DETALS OF SEWER
CONNECTON . COMPLY WTH RELEVANTAUTHORTES REQUREMENTS.
SUPPLY & NSTALLALL ELECTRCAL SERVCES NCLUDNG BUT NOT
LMTED TO, POWER, EXT SGNS, EMERGENCY LFTNG & TELEPHONE
SUPPLY TO RELEVANT AUST STANDARDS & AUTHORTES REQUREMENTS.
SUPPLY & NSTALLALL MECHANCAL VENTLATON NCLUDNG BUT NOT
LMTED TO, MECHANCAL EXHAUST FANS & DUCTS, AR CONDTONNG
UNTS & DUCTS TO RELEVANTAUST STANDARDS & AUTHORTES
REQUREMENTS.
REMOVE ALL REDUNDANT VEHCLE CROSSNGS & REPLACED WTH KERB &
GUTTER TO COUNCL'S REQUREMENTS. MAKE GOOD TO SURROUNDS
WHERE DSTURBED BY NEW WORKS TO COUNCL ENGNEER'S
SPECFCATON.
PROVDE PHYSCAL TERMTE TREATMENT N ACCORDANCE WTH AS 3660.1
WC WTH NWARD SWNGNG DOORS CLOSER THAN 1200mm TO THE PAN
SHALL BE FTTED WTH LFT OFF HNGES AS REQURED BY BCA.
UNO. PROVDE 50mm SET DOWN N FLOOR SLAB TOALL WET AREAS. LAY
PAVNGWTH SUFFCENT FALL TO FLOOR WASTE TOAVOD PONDNG.
MAKE GOOD TOALL SURFACES, DAMAGED / EFFECTED DURNG NEW
WORKS
AT COMPLETON CLEAN UP THE STE PROR TO HAND OVER. MAKE GOOD
TO SURROUNDS WHERE DSTURBED DURNG NEWWORKS.
LEGEND - WALL TYPES
EXSTNG 270mm CAVTY BRCK WALL. FACE BRCK
EXTERNAL & NEW 13mm PLASTERBOARD LNNG ON
FURRNG CHANNELS TOALL VSBLE FACES OF
BRCKWORK NTERNAL.Min. R2.1 NSULATON TOALL
NEW & EXSTNG OFFCE/LUNCH ROOM WALLS ONLY.
SET READY FOR SELECTED PANT FNSH.MAKE
GOOD TOALL SURFACES EFFECTED BY NEW WORK.
NOM. 90mm STEEL STUD FRAMED WALL TO U/SDE OF
CELNG. C/W 13mm PLASTERBOARD LNNG BOTH
SDES OF FRAMNG, SET READY FOR SELECTED
PANT FNSH (OFFCES) OR C/W F.C. LNNG &
CERAMC TLES (WET AREAS). ALL WALLS N WET
AREAS TO EXTEND 100mm PAST CELNG LNNG
NEW 270mm CAVTY BRCK WALL TO MATCH
EXSTNG. FACE BRCK EXTERNAL & 13mm
PLASTERBOARD LNNG ON FURRNG CHANNELS TO
ALL VSBLE FACES OF BRCKWORK NTERNAL. SET
READY FOR SELECTED PANT FNSH.
NOM. 90mm STEEL STUD FRAMED WALL 3.6m HGH.
C/W MN. R0.9 NSULATON & 2 LAYERS OF 13mm
PLASTERBOARD LNNG BOTH SDES OF FRAMNG,
EQUAL TO BORAL WALL SYSTEM S2626. (WET AREA
PLASTERBOARD TO NTERNAL OF WET AREAS) , SET
READY FOR SELECTED PANT FNSH.
EXSTNG 230mm NTERNAL BRCK WALL. NEW 13mm
PLASTERBOARD LNNG ON FURRNG CHANNELS TO
BOTH FACES OF BRCKWORK. SET READY FOR
SELECTED PANT FNSH.MAKE GOOD TOALL
SURFACES EFFECTED BY NEW WORK.
NEW 230mm NTERNAL NFLL BRCK WALL. 13mm
PLASTERBOARD LNNG ON FURRNG CHANNELS TO
BOTH FACES OF BRCKWORK.SET READY FOR
SELECTED PANT FNSH.
EXSTNG 190mm NTERNAL CONCRETE BLOCK WALL.
NEW 13mm PLASTERBOARD LNNG ON FURRNG
CHANNELS TO EXTERNAL FACE OF BLOCKWORK. SET
READY FOR SELECTED PANT FNSH.MAKE GOOD TO
ALL SURFACES EFFECTED BY NEW WORK.
ESSENTIAL EMERGENCY SERVICES
H

E/L
EXTG
- HYDRANTS
- FRE EXTNGUSHERS
- FRE HOSE REELS
- EMERGENCY LGHTNGS
- LLUMNATED EXT LGHTNGS
- ALL PORTABLE FRE EXTNGUSHERS & FRE BLANKETS TO
COMPLY WTH RELEVANT AUST. STANDARDS.
- EMERGENCY AND EXT LGHTNGS TO BE STANLITE OR
APPROVED EQUAL AND SHALL COMPLY WTH ASNZS 2293.1
- REFER ALSO TO FRE SERVCES CONSULTANTS
DOCUMENTATON.
- ALL NEW WORKS TO COMPLY WTH AS1428 & PART D3 OF BCA,
ACCESS FOR PEOPLE WTH DSABLTES.
- TACTLE NDCATORS TO COMPLY WTH RELEVANT AUST.
STANDARDS.
S
Legend:
RH -RANGE HOOD
RS -ROTATNG SHELVES
S -KTCHEN SNK
SCR -SHOWER CURTAN RAL
SF -SHELF
SH -SOAP HOLDER
SHR -SHOWER
SHS -SHOWER SCREEN
SRS -SHOWER ROSE
ST -COOKNG STOVE
STF -STEEL TROWEL FNSHED
CONCRETE
TC -TMBER CLADDNG AS SPEC.
TL -TMBER LOUVERS
TPH -TOLET PAPER HOLDER
TR -TOWEL RAL
TUB -LAUNDRY TUB
VTY -VANTY UNT
V -VNYL
VSK -VNYL SKRTNG
WC -TOLET SUTE
WM -WASHNG MACHNE
WO -WALL OVEN
-SMOKE DETECTOR
ASR -ADJUST. SHOWER ROSE
B -BOLLARD
BP -BAGGED WASH & PANTED
BSN -BASN
BTH -BATH
BR -BROOM CUPBOARD
C -CARPET AS SPECFED
CAP -CELNG ACCESS PANEL
CR -CEMENT RENDERED FNSH
CT -CERAMC TLES
CTP -COOK TOP
DWU -DRAWER UNT
FG -FXED GLASS
FW -FLOOR WASTE
GL -GLASS LOUVERS
GR -GRAB RAL
HDT -HARDWOOD DECKNG TMBER
HWU -HOT WATERUNT
MR -MRROR
PB -PLASTERBOARD LNNG
PBC -PLASTERBOARD CORNCE
PTF -POLSHED TMBER FLOOR
BOARDS
NS-CT -NON-SLP CERAMC TLE
R -TOWEL RNG
REF -REFRGERATOR
1
SITE / GROUND FLOOR PLAN
1:100
GENERAL WALL NOTES
PLASTERBOARD CONTRACTOR TOALLOW FOR ALL NOGGNG TO
CATER FOR HANDLES, HARDWARE FTTNGS.
PROVDE FC LNNG ON FURRNG CHANNELS TO SOLD MASONRY
WALLS FOR PLUMBNG BEHND SANTARYFTTNGS
USE MN. 92mm STUD FOR PLASTERBOARD WALLS, F A URNAL OR 2
OR MORE VANTY BASNS ARE TO BE FXED AGANST THAT WALL
PROVDE ALUMNUM SKRTNGS TOALL WALLS EXCEPT WHERE
SKRTNG DUCT, CERAMC TLE OR VNYL SPECFED