Architectural Drawing
Architectural Drawing
V
84 Locker Change Room
waterless wall
hung urinals
shr shr shr shr shr
shr
shr
Lockers (2 tier)
L o c k e r s (2 t i e r)
L o c k e r s
B
e n c h
Bench
Rose Street
Ct
Ct
B B
F
a l l
CInr
B B B
(2 t i e r)
F
H
R
EXT
F
a l l
Ct
Break out
Room
B e n c h C
'p d
NS-CT
NS-CT
DP DP
Ct
Break out
Room
Photocopy/
Stationary Room
Ct
Lockers (2 tier)
B
e n c h
Ct
Emergency Room/
Meeting Room/
Hot Desk Room
BOOK SHELVES BOOK SHELVES BOOK SHELVES
E
X
T
EXT
E
X
T
D
0 3
D
0 4
D
0 5
D
0 6
R
E
F
.
Existing structural column.
Existing structural column.
ndicative office plan
layout. Loose
Furniture by others.
6
Locker
Change
Room
D
2 4
New entrance portal. Face brick walls,
timber framed roof, to eng's detail, with
ACM cladding. Refer to spec.
ndicative location of
proposed A/C units.
Provided recessed floor mat.
Vertical aluminium louvres attatched
to galvanised steel frame to eng.
details. With ACM clad steel frame
awning overhead to eng. details.
Vertical aluminium louvres attatched
to galvanised steel frame to eng.
details. With ACM clad steel frame
awning overhead to eng. details.
Proposed timber framed
awning overhead, to eng's
detail. Refer to roof plan.
ndicative location of proposed
seperate A/C unit for server room.
New reinforced concrete slab to eng's
detail.
Existing kerb.
ndicative Lunch Room layout.
Furniture provided by others
Top existing slab in amenities area to allow for CT
with sufficient falls to FW's. Allow to taper/fall FLR
finish in corridors to blend/match existing FLR level.
New reinforced concrete slab pathway
to eng's detail.
Existing structural column.
New bollards as specified
Existing face brick columns to remain
Provide 13mm plasterboard
lining on furring channels to all
visible external faces of the
existing walls of the lunch room
Provide sealed joint to gap /
cavity between new walls / slab
& the existing brick wall
Provide 13mm plasterboard
lining on furring channels to all
visible internal faces of the
existing walls.
Provide 13mm plasterboard
lining on furring channels to all
visible faces of brickwork in the
lunch room
Refer to Legend - Plan
for wall description.
Extent of new
slab under
Extent of new slab under.
To be confirmed.
Extent of new
slab under
Extent of new
slab under.
Operable wall
Extent of new
slab under
10 x Hot Desks
Lower sill and replace existing
windows with new aluminium
framed extruded windows - refer
to schedule for details
Lower sill and replace existing
windows with new aluminium
framed extruded windows - refer
to schedule for details
Provide new skylights over
GENERAL NOTES:
VERFY ON STE ALL SURVEY NFORMATON NCLUDNG ALL EXSTNG
SERVCES & LEVELS PROR TO CONSTRUCTON.
DEMOLSH EXTG STRUCTURES & CLEAR ALL VEGETATONAS REQURED
AND/OR AS SHOWN ON DRAWNGS, READY FOR NEWWORKS. DSPOSE OF
DEMOLSHED BULDNG MATERALSAND ASBESTOS MATERAL
ENCOUNTERED DURNG DEMOLTON, EXCEPT THOSE TEMS SPECFCALLY
DENTFED FOR REUSE.
TERMNATE, CAP OFF OR DVERT OF ALL EXSTNG SERVCES WHERE SO
REQURE AND/OR AS NECESSARY TO CARRY OUT NEW WORKS. PERFORM
ALL WORKS N BEST TRADESMAN-LKE MANNER AND TO THE SATSFACTON
OF RELEVANTAUTHORTES.
REFER TO STRUCTURAL ENG'S DOCUMENTS FOR DETALS OF CONC.
SLABS, STEPS, FOOTNGS NCLUDNG SZES OF STRUCTURAL MEMBERS.
ALL TMBER FRAMNG SZES SHALL COMPLYWTH THE TMBER FRAMNG
CODE.
COMPLYWTH LANDSCAPNG REQUREMENTS AS REQURED BY THE
COUNCL CONDTONS AND/OR AS DETALED BY LANDSCAPE ARCHTECT .
REFER TO HYDRAULC ENG'S DETALS FOR LOCATONAND LEVELS OF ALL
STORM WATERPTS. UNO. CONNECT ALL DOWNPPES NTO NEAREST
EXSTNG STORM WATERSYSTEM AS REQURED AND/OR TO HYD. ENG'S
DETALS. UNO. PROVDE FALL N GROUND FNSHES TO ENSURE ALL
STORM WATER FALLS AWAYFROM BULDNG. LAY PAVNGWTH
SUFFCENT FALL TO PT TOAVOD PONDNG.
REFER TO HYDRAULC ENG'S DETALS FOR DETALS OF SEWER
CONNECTON . COMPLY WTH RELEVANTAUTHORTES REQUREMENTS.
SUPPLY & NSTALLALL ELECTRCAL SERVCES NCLUDNG BUT NOT
LMTED TO, POWER, EXT SGNS, EMERGENCY LFTNG & TELEPHONE
SUPPLY TO RELEVANT AUST STANDARDS & AUTHORTES REQUREMENTS.
SUPPLY & NSTALLALL MECHANCAL VENTLATON NCLUDNG BUT NOT
LMTED TO, MECHANCAL EXHAUST FANS & DUCTS, AR CONDTONNG
UNTS & DUCTS TO RELEVANTAUST STANDARDS & AUTHORTES
REQUREMENTS.
REMOVE ALL REDUNDANT VEHCLE CROSSNGS & REPLACED WTH KERB &
GUTTER TO COUNCL'S REQUREMENTS. MAKE GOOD TO SURROUNDS
WHERE DSTURBED BY NEW WORKS TO COUNCL ENGNEER'S
SPECFCATON.
PROVDE PHYSCAL TERMTE TREATMENT N ACCORDANCE WTH AS 3660.1
WC WTH NWARD SWNGNG DOORS CLOSER THAN 1200mm TO THE PAN
SHALL BE FTTED WTH LFT OFF HNGES AS REQURED BY BCA.
UNO. PROVDE 50mm SET DOWN N FLOOR SLAB TOALL WET AREAS. LAY
PAVNGWTH SUFFCENT FALL TO FLOOR WASTE TOAVOD PONDNG.
MAKE GOOD TOALL SURFACES, DAMAGED / EFFECTED DURNG NEW
WORKS
AT COMPLETON CLEAN UP THE STE PROR TO HAND OVER. MAKE GOOD
TO SURROUNDS WHERE DSTURBED DURNG NEWWORKS.
LEGEND - WALL TYPES
EXSTNG 270mm CAVTY BRCK WALL. FACE BRCK
EXTERNAL & NEW 13mm PLASTERBOARD LNNG ON
FURRNG CHANNELS TOALL VSBLE FACES OF
BRCKWORK NTERNAL.Min. R2.1 NSULATON TOALL
NEW & EXSTNG OFFCE/LUNCH ROOM WALLS ONLY.
SET READY FOR SELECTED PANT FNSH.MAKE
GOOD TOALL SURFACES EFFECTED BY NEW WORK.
NOM. 90mm STEEL STUD FRAMED WALL TO U/SDE OF
CELNG. C/W 13mm PLASTERBOARD LNNG BOTH
SDES OF FRAMNG, SET READY FOR SELECTED
PANT FNSH (OFFCES) OR C/W F.C. LNNG &
CERAMC TLES (WET AREAS). ALL WALLS N WET
AREAS TO EXTEND 100mm PAST CELNG LNNG
NEW 270mm CAVTY BRCK WALL TO MATCH
EXSTNG. FACE BRCK EXTERNAL & 13mm
PLASTERBOARD LNNG ON FURRNG CHANNELS TO
ALL VSBLE FACES OF BRCKWORK NTERNAL. SET
READY FOR SELECTED PANT FNSH.
NOM. 90mm STEEL STUD FRAMED WALL 3.6m HGH.
C/W MN. R0.9 NSULATON & 2 LAYERS OF 13mm
PLASTERBOARD LNNG BOTH SDES OF FRAMNG,
EQUAL TO BORAL WALL SYSTEM S2626. (WET AREA
PLASTERBOARD TO NTERNAL OF WET AREAS) , SET
READY FOR SELECTED PANT FNSH.
EXSTNG 230mm NTERNAL BRCK WALL. NEW 13mm
PLASTERBOARD LNNG ON FURRNG CHANNELS TO
BOTH FACES OF BRCKWORK. SET READY FOR
SELECTED PANT FNSH.MAKE GOOD TOALL
SURFACES EFFECTED BY NEW WORK.
NEW 230mm NTERNAL NFLL BRCK WALL. 13mm
PLASTERBOARD LNNG ON FURRNG CHANNELS TO
BOTH FACES OF BRCKWORK.SET READY FOR
SELECTED PANT FNSH.
EXSTNG 190mm NTERNAL CONCRETE BLOCK WALL.
NEW 13mm PLASTERBOARD LNNG ON FURRNG
CHANNELS TO EXTERNAL FACE OF BLOCKWORK. SET
READY FOR SELECTED PANT FNSH.MAKE GOOD TO
ALL SURFACES EFFECTED BY NEW WORK.
ESSENTIAL EMERGENCY SERVICES
H
E/L
EXTG
- HYDRANTS
- FRE EXTNGUSHERS
- FRE HOSE REELS
- EMERGENCY LGHTNGS
- LLUMNATED EXT LGHTNGS
- ALL PORTABLE FRE EXTNGUSHERS & FRE BLANKETS TO
COMPLY WTH RELEVANT AUST. STANDARDS.
- EMERGENCY AND EXT LGHTNGS TO BE STANLITE OR
APPROVED EQUAL AND SHALL COMPLY WTH ASNZS 2293.1
- REFER ALSO TO FRE SERVCES CONSULTANTS
DOCUMENTATON.
- ALL NEW WORKS TO COMPLY WTH AS1428 & PART D3 OF BCA,
ACCESS FOR PEOPLE WTH DSABLTES.
- TACTLE NDCATORS TO COMPLY WTH RELEVANT AUST.
STANDARDS.
S
Legend:
RH -RANGE HOOD
RS -ROTATNG SHELVES
S -KTCHEN SNK
SCR -SHOWER CURTAN RAL
SF -SHELF
SH -SOAP HOLDER
SHR -SHOWER
SHS -SHOWER SCREEN
SRS -SHOWER ROSE
ST -COOKNG STOVE
STF -STEEL TROWEL FNSHED
CONCRETE
TC -TMBER CLADDNG AS SPEC.
TL -TMBER LOUVERS
TPH -TOLET PAPER HOLDER
TR -TOWEL RAL
TUB -LAUNDRY TUB
VTY -VANTY UNT
V -VNYL
VSK -VNYL SKRTNG
WC -TOLET SUTE
WM -WASHNG MACHNE
WO -WALL OVEN
-SMOKE DETECTOR
ASR -ADJUST. SHOWER ROSE
B -BOLLARD
BP -BAGGED WASH & PANTED
BSN -BASN
BTH -BATH
BR -BROOM CUPBOARD
C -CARPET AS SPECFED
CAP -CELNG ACCESS PANEL
CR -CEMENT RENDERED FNSH
CT -CERAMC TLES
CTP -COOK TOP
DWU -DRAWER UNT
FG -FXED GLASS
FW -FLOOR WASTE
GL -GLASS LOUVERS
GR -GRAB RAL
HDT -HARDWOOD DECKNG TMBER
HWU -HOT WATERUNT
MR -MRROR
PB -PLASTERBOARD LNNG
PBC -PLASTERBOARD CORNCE
PTF -POLSHED TMBER FLOOR
BOARDS
NS-CT -NON-SLP CERAMC TLE
R -TOWEL RNG
REF -REFRGERATOR
1
SITE / GROUND FLOOR PLAN
1:100
GENERAL WALL NOTES
PLASTERBOARD CONTRACTOR TOALLOW FOR ALL NOGGNG TO
CATER FOR HANDLES, HARDWARE FTTNGS.
PROVDE FC LNNG ON FURRNG CHANNELS TO SOLD MASONRY
WALLS FOR PLUMBNG BEHND SANTARYFTTNGS
USE MN. 92mm STUD FOR PLASTERBOARD WALLS, F A URNAL OR 2
OR MORE VANTY BASNS ARE TO BE FXED AGANST THAT WALL
PROVDE ALUMNUM SKRTNGS TOALL WALLS EXCEPT WHERE
SKRTNG DUCT, CERAMC TLE OR VNYL SPECFED