Figure 1 - Schematic of a typical split range control loop In figure1, PIC-01 controls the pressure of the separator for liquid-vapor hydrocarbons, by mean of a split range controller with the output signal split and sent to two pressure control valves PV-A and PV-B. When pressure increases, the fluid shall be discharged to flare. When the pressure decreases, Fuel gas is introduced to compensate the pressure of the separator The fuel gas valve (PV-B) needs to close in response to increasing of pressure of the separator, while the flare valve (PV-A) will need to open when the pressure increases beyond setpoint. - When the pressure increases beyond setpoint in range of with 0-50% controller output, PV-B shall close from fully open to fully close. - When the pressure increases beyond setpoint in range of with 50-100% controller output, PV-A shall open from fully close to fully open. In summary, valve actions by PIC-01 is as follow:
Figure 2 - Controller output versus valve opening for split range controller In this case, the service of both control valves is different, with respect to use of fuel gas and flaring for pressure control. Another case of use of split range control loop is when one control valve cannot be suitably designed to cover the complete operating range of the controller. In that case, valve with a smaller Cv operated between 0-50% range and the other operates for 50-100% range. For example, a pressure controller for accumulator drum in overhead of a stabilizer column splits range to open 2 control valves. In the low range (0-50 % range in response to high pressure of the stabilizer), the off gas is routed to a gas plant downstream, in the high range (50-100% range in response to high high pressure of the stabilizer) the off gas goes to flare by opening of valve B. The control valve actions is as follow:
Related Posts Typical control valve datasheet pneumatically actuated valve Distillation range Control Valves Typical P&ID arrangement Self Actuated Pressure Control Valve Motor Operated Valve Related Pages Instrumentation Control Valves Previous Next
Member Login
Sign up now
Sign up for free if you are not a member already. Home Piping Miscellaneous Process Design Solved Examples Newsletter Calculators Unit Conversion Contact Us
Request a Calculator
Request for a free engineering calculator to be added to EnggCyclopedia.
Mumbai Virtual Offices Temperature process control Control Valves 1/2/3+ BHK Apts in Mumbai
Popular Pages Recent Pages Heat Exchanger Shellside Pressure Drop Control Valves Logarithmic Mean Temperature Difference (LMTD) - Correction Factor calculator Strainer pressure drop calculator 2 Phase separator design calculator - Horizontal Knock Out Drum Search for: Search Search
Popular Calculators
Pressure Volume Temperature Density Popular Post Recent Posts Gas Compression Sample Problem - Vertical Knock Out Drum Sizing Calculations Specific heat ratio / Adiabatic index Types of Refrigerants Problem solving - Heat exchanger shellside pressure drop calculation
Physical Properties Piping Dimensions Pressure Drop Instrument Sizing Equipment Sizing
Categories
Codes and Standards Electrical Equipments Engineering Questions Instrumentation Miscellaneous Operation & Maintenance Petroleum products Physical Properties Piping Process Design Safety / Loss Prevention Solved Sample Problems