SECTION 15000 Heating, Ventilating & Airconditioning Installations 1.01 Scope of Work

This document outlines the HVAC scope of work and requirements for a chalet service centre project in Kuwait. Key points include: 1. The HVAC work includes package and split air conditioning systems, ventilation systems, and testing/commissioning of all equipment. 2. Design conditions for summer and winter in Kuwait are specified. 3. Submittals such as shop drawings, construction programs, and operation/maintenance manuals are required from the contractor. 4. Testing, adjusting, balancing and a two-year maintenance period is required to ensure proper performance of the HVAC systems.

Uploaded by

abobeedo
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views5 pages

SECTION 15000 Heating, Ventilating & Airconditioning Installations 1.01 Scope of Work

This document outlines the HVAC scope of work and requirements for a chalet service centre project in Kuwait. Key points include: 1. The HVAC work includes package and split air conditioning systems, ventilation systems, and testing/commissioning of all equipment. 2. Design conditions for summer and winter in Kuwait are specified. 3. Submittals such as shop drawings, construction programs, and operation/maintenance manuals are required from the contractor. 4. Testing, adjusting, balancing and a two-year maintenance period is required to ensure proper performance of the HVAC systems.

Uploaded by

abobeedo
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 5

CHALET SERVICE CENTRE KUWAIT

SECTION 15000 HEATING, VENTILATING & AIRCONDITIONING INSTALLATIONS 1.01 SCOPE OF WORK 1. *. -. Provide all Heating, Ventilating and Air Conditioning wor ! "o#$lete in a""ordan"e wit% t%e re&'ire#ent! o( t%e Contra"t )o"'#ent!. T%i! Contra"t do"'#ent i! #eant onl+ to !%ow t%e de!ign "on"e$t and general arrange#ent o( wor ! a! re&'ired to ,e done ,+ t%e Contra"tor. T%e .o, in"l'de! (or HVAC de!ign, in!tallation, o$eration, te!ting, "o##i!!ioning, %anding over in $er(e"t r'nning "ondition and #aintenan"e for two y !r" o( t%e w%ole in!tallation (ro# t%e date o( %anding over and (ive +ear! (or "o#$re!!or. All e&'i$#ent !%all ,e !ele"ted and de!igned to r'n at K'wait a#,ient "ondition! wit%o't tri$$ing, over%eating or e((e"ting t%e !%a$e or "on!tr'"tion o( t%e e&'i$#ent. 1EW and 1PW general r'le! and reg'lation! !%all ,e "on!idered a! a $art o( t%i! Contra"t )o"'#ent.

/.

0.

2. HVAC Wor ! !%all ,e e3e"'ted ,+ an a$$roved !$e"iali!t S',4Contra"tor and !%all ,e o( !e"ond "ategor+ a! de(ined ,+ t%e Central Tendering Co##ittee 5CTC6. 1.0# SECTIONS T%i! Se"tion and t%e (ollowing )ivi!ion 10 Se"tion! are a$$li"a,le to Heating, Ventilating and Air Conditioning In!tallation!. SECTION 101/7 10*/0 10*27 10*87 10070 109:* 109:/ 10:20 10:97 10::0 10:87 10817 108/7 PART 1 $ GENERAL 1.0% &'ALIT( ASS'RANCE )Co* " !+* St!+*!r*",
1077741

TITLE S'$$ort! and An"%or!. Vi,ration I!olation. Pi$ing In!'lation. )'"twor In!'lation. Pa" age Roo( To$ )ire"t E3$an!ion Air Conditioning Unit!. S$lit S+!te# )ire"t E3$an!ion Air Conditioning Unit!. Roo# S$lit S+!te# Air Conditioning S+!te#. A3ial ;an!. Power Roo( Ventilation. Air Cleaning E&'i$#ent. )'"t Wor . )'"t Wor A""e!!orie!. Air <'tlet! and Inlet!.

<HA EN=INEERIN= C<NSULTANT HVAC S>STE1.

CHALET SERVICE CENTRE KUWAIT

A.

Con(or# to t%e re&'ire#ent! o( t%e (ollowing ? 1. Code!, <rdinan"e!, R'le! and Reg'lation! o( t%e State o( K'wait and it! law('l en(or"e#ent agen"ie!. *. 1ini!tr+ o( Ele"tri"it+ and Water, K'wait 51EW @ Reg'lation!6. -. 1ini!tr+ o( P',li" Wor !, K'wait 51PW @ Reg'lation!6. /. A#eri"an So"iet+ o( Heating, Re(rigeration and Air Conditioning Engineer!, In". USA. 5ASHRAE6 0. National ;ire Prote"tion A!!o"iation, 5N;PA6. 2. K'wait ;ire Arigade, 5K;A6. 9. :. 8. 17. 11. S1ACNA ? S%eet 1etal Air Conditioning Contra"tor! National A!!o"iation.. AS1E ? A#eri"an So"iet+ o( 1e"%ani"al Engineer! UL ? Underwriter La,oratorie!. NE1A? National Ele"tri"al 1otor A!!o"iation. ARI ? Air Conditioning Re(rigeration In!tit'te.

1.0A.

S'./ITTALS S',#it #ont%l+ !tat'! re$ort! o( t%e (ollowing? 1. *. -. /. 1aterial! !',#ittal and a$$roval. 1aterial! re"ei$t at !ite. S%o$ drawing! !',#ittal and a$$roval. Progre!! drawing!, #ar ed in !e$arate "olor! (or ea"% #ont%.

A.

S',#it "on!tr'"tion $rogra##e! ? 1. *. Ai4wee l+ ,ar "%art!. Te!ting and "o##i!!ioning $rogra##e!.

C.

S',#it / "o$ie! o( t%e $rod'"t data and !%o$ drawing!. Allow (or 5/6 wee ! (or review and a$$roval, ,e(ore $la"ing order or "o##en"ing wor . 1. *. -. 1an'(a"t'rer! $rinted ,ro"%'re! and "atalog'e! 5one original and t%ree "o$ie!6 wit% relevant in(or#ation %ig% lig%ted, along wit% write '$ o( !ele"tion "riteria. =eneral d'"ting and $i$ing la+o't drawing! to a !"ale not !#aller t%an 1?07. E&'i$#ent in!tallation and $i$ing la+o't, do',le line drawing! "learl+ indi"ating all (itting!, !'$$ort!, valve! et". to a !"ale o( 1?*7. S',#it !e"tion! and wall elevation! a! a$$ro$riate. A'ilderB! wor la+o't $lan! to a !"ale o( 1?77C1?07 a! a,ove. Ele"tri"al wiring diagra#! 5NTS6 detail! 51?*76. Cal"'lation!Cdetail! to !',!tantiate t%e !%o$ drawing!. Te!t and $er(or#an"e "erti(i"ate o( e&'i$#ent, w%ere re&'ired.

/. 0. 2. 9.

<HA EN=INEERIN= C<NSULTANT HVAC S>STE1.

107774*

CHALET SERVICE CENTRE KUWAIT

).

S',#it re"ord drawing! o( all wor ! in!talled 'nder t%i! !e"tion, a! (ollow!? 1. *. <ne 516 Se$ia. ;o'r 5/6 $rint!, (olded in A/ !iDe and (iled.

E. ;.

S',#it one 516 %ard ,o'nd "o$+ and one $%oto "o$+ o( E<$eration! and #aintenan"e 1an'alF, wit% "o#$lete data (or ea"% $ie"e o( e&'i$#ent in!talled. All re"ord drawing !%o'ld ,e on Co#$a"t )i!"! EIA1 Co#$ati,le ;or#atF. PART # $ S(STE/ DESCRIPTION

#.01

.'ILDING DESCRIPTION

T%e Pro.e"t "on!i!t! o( t%ree T+$i"al C%alet SERVICE CENTRE ,'ilding!. #.0# A. .'ILDING HVAC S(STE/S 0 Air Conditioning !+!te#! ? 1. *. A. )G $a" age and !$lit !+!te#!. 1ini !$lit (or !e"'rit+ and #e"%ani"al roo#

Ventilation !+!te# ? 1. *. -. E3%a'!t !+!te# (or ,at%roo#! t%ro'g% roo( E3%a'!t ;an!. S#o e e3%a'!t !+!te# a! a$$roved (ro# K;). E3%a'!t !+!te# (or tran!(or#ar roo# a! a$$roved (ro# 1EW.

#.0% A.

DESIGN CONDITIONS <'tdoor )e!ign Condition! S'##er Winter -0 -7 8.1 110 :* 11.*

)r+ ,'l, te#$erat're, deg. ; Wet ,'l, te#$erat're, deg. ; Prevailing Wind 5N.W.6, 1PH A. In!ide )e!ign Condition!

)r+ ,'l, te#$erat're, deg. ; 90 Relative H'#idit+, H 07 5Indoor %'#idi(i"ation a!!'#ed (or load "al"'lation onl+6. C. Toilet! Ventilation Criteria ? 17 Air C%ange!CHo'r. 11.*

9* -0

Prevailing Wind 5N.W.6, 1PH

8.1

<HA EN=INEERIN= C<NSULTANT HVAC S>STE1.

107774-

CHALET SERVICE CENTRE KUWAIT

PART % $ E1EC'TION %.01 A. A. COORDINATIONS St'd+ all drawing! and !$e"i(i"ation and (a#iliariDe wit% t%e Str'"t'ral and Ar"%ite"t'ral detail! and t%e wor o( ot%er trade!. En!'re t%at t%e wor 'nder t%i! !e"tion, will not inter(ere wit% t%o!e o( ot%er trade! and are "o#$ati,le wit% t%e Ar"%ite"t'ral (ini!%e!, $rior to $la"ing order!, (a,ri"ation and in!tallation. In(or# t%e Ele"tri"al "ontra"tor (or t%e e3a"t $ower re&'ire#ent! and lo"ation and t+$e o( t%e inter(a"e. ;'rni!% all in(or#ation a! re&'ired ,+ t%e 1EW (or o,taining a$$roval!. ;'rni!% t%e Civil Wor ! Contra"tor wit% ne"e!!ar+ te#$late!, $attern!, !etting o't $lan! and ot%er ite#! (or in"or$oration in %i! wor ! or (or leaving ne"e!!ar+ $rovi!ion! (or t%e wor . En!'re ti#el+ $la"e#ent o( !leeve!, in!ert! and t%e li e. W%ere wor i! in!talled in "lo!e $ro3i#it+, to or will inter(ere wit% ot%er wor !, a!!i!t in wor ing o't !ati!(a"tor+ !$a"ed arrange#ent!. Pre$are "o#$o!ite !%o$ drawing! to a !'ita,le !"ale, !%owing %ow t%e wor i! in!talled in relation o( t%e wor o( ot%er trade!. En!'re t%e !'((i"ien"+ o( di#en!ion! o( t%e $lant area!, door! et". and t%e !'ita,ilit+ o( !la,! and ot%er !tr'"t'ral #e#,er! (or $la"e#ent, o$eration and #aintenan"e o( e&'i$#ent. Re!olve "on(li"t! in re&'ire#ent! wit% ot%er trade!. Re(er to t%e Ar"%ite"t onl+ t%o!e t%at "annot ,e !olved, wit%o't "%ange! to !tr'"t're or t%o!e w%i"% involve! #a.or "%ange! to !+!te# de!ign.

C.

).

E.

;.

=.

%.0# A.

INSPECTION, TESTING, AD2'STING AND .ALANCING )'ring in!tallation and a(ter "o#$letion o( wor !, t%e !+!te#, !e"tion! o( t%e !+!te# or it! "o#$onent! !%all ,e te!ted ,+ t%e Contra"torCS$e"iali!t S',"ontra"tor in t%e $re!en"e o( t%e Engineer a! dire"ted ,elow or el!ew%ere. T%e Contra"tor !%all $ro"'re all te!ting in!tr'#ent! and a""e!!orie! and ,ear all "o!t! in "onne"tion wit% t%e !a#e ? 1. *. -. /. ,a!i" #aterial! (or "on(or#it+ wit% t%e !$e"i(ied !tandard!. S'$$ort! and an"%or! (or a,ilit+ to wit%!tand re&'ired load!. Heat tran!(er e&'i$#ent (or ('ll load "a$a,ilit+, "ontrol!, !a(et+ interlo" , and alar#! and o$eration o( !a(et+ valve!. Control !+!te# (or o$erating range!, toleran"e!, "'to't, alar# et".

A.

Carr+ o't t%e te!ting, ad.'!ting and ,alan"ing o( t%e HVAC E&'i$#ent and !+!te#! a! dire"ted ,+ t%e Engineer.
107774/

<HA EN=INEERIN= C<NSULTANT HVAC S>STE1.

CHALET SERVICE CENTRE KUWAIT

Te!t, Ad.'!t and ,alan"e !+!te# d'ring !'##er !ea!on (or air "onditioning !+!te#! and d'ring winter !ea!on (or %eating !+!te#, in"l'ding at lea!t $eriod o( o$eration at o't!ide "ondition! wit%in 0 )eg. ;. 5- )eg. C6 wet ,'l, te#$erat're o( #a3i#'# !'##er )e!ign "ondition, and wit%in 17 )eg. ;. 52 deg. C.6 dr+ ,'l, te#$erat're o( #ini#'# winter de!ign "ondition. W%en !ea!onal o$eration doe! not $er#it #ea!'ring (inal te#$erat're, t%en ta e (inal te#$erat're reading!, w%en !ea!onal doe! $er#it. %.0% A. G'ARANTEED /AINTENANCE Provide w%en re&'ired t%e !ervi"e o( t%e "o#$etent $er!onnel o( t%e HVAC ro'tine #aintenan"e !ervi"e! d'ring g'aranteed $eriod a! $er #an'(a"t'rer! $ro$o!ed #aintenan"e !"%ed'le ,'t +ot 3 "" t4!+ two y !r". TW< >EARS =UARANTEE AN) 1AINTENANCE PERI<) 5;or all 1e"%ani"al6 T%e Contra"tor !%all #aintain, re$la"e and re$air wit% 't#o!t !$eed and at %i! own e3$en!e an+ $art o( t%e $lant or #aterial or wor $er(or#ed or ('rni!%ed 'nder t%e !ervi"e! in t%e Contra"t w%i"% #a+ $rove de(e"tive in de!ign, ere"tion, o$eration, $er(or#an"e, wor #an!%i$, et". wit%in two +ear! a(ter t%e wor ! %ave ,een ta en over ,+ t%e Engineer. 1aintenan"e w%i"% !%o'ld "over all ne"e!!ar+ !$are $art!, oil!, l',ri"ant!, re(rigerant!, et". till t%e re&'ired #aintenan"e $eriod. T%e Contra"tor !%all o,tain and !',#it to t%e Engineer an+ g'arantee or "erti(i"ate! or warrant+ availa,le (ro# t%e #an'(a"t'rer!. I( an+ de(e"t i! not re#edied wit%in a rea!ona,le ti#e, t%e P'r"%a!er #a+ $ro"eed to do t%e wor at t%e Contra"torB! ri! and e3$en!e. T%e Contra"tor !%all in"l'de (or "o#$lete !ea!onal ro'tine #aintenan"e "%e" ! o( all $lant! and e&'i$#ent. T%e Contra"tor !%all ,e re!$on!i,le in t%e la!t ro'tine "%e" $re"eding t%e end o( t%e g'aranteed #aintenan"e $eriod to de#on!trate t%at t%e o$eration o( t%e "o#$letion !+!te# in"l'ding t%e a'to#ati" "ontrol!, interlo" ! and a !a(et+ devi"e! (or t%e vario'! $lant! and a'3iliarie! are in !ati!(a"tor+ wor ing order. All t%e re&'ired "%e" ! or te!t! !%all ,e witne!!ed ,+ t%e Area EngineerB! re$re!entative. T%e Contra"tor !%all $re$are and (ill t%e ro'tine !"%ed'le! !tating t%e date, (re&'en"+, t+$e o( #aintenan"e !ervi"e "arried o't and na#e o( t%e EngineerB! re$re!entative $re!ent and !%all !',#it t%e !a#e in d'$li"ate to t%e Engineer a(ter ever+ "%e" . C. ;ive >ear! ='arantee and 1aintenan"e Period 5;or ACC Unit! Co#$re!!or!6 T%e Contra"tor !%all #aintain, re$la"e and re$air wit% 't#o!t !$eed and at %i! own e3$en!e all ACC #a"%ine! "o#$re!!or! wit%in ;ive +ear! a(ter t%e wor ! %ave ,een ta en over ,+ t%e Engineer. END OF SECTION

A.

<HA EN=INEERIN= C<NSULTANT HVAC S>STE1.

1077740