Industrial Lighting Best Practices
Randy Johnson US Lamp, Inc.
Industrial Lighting Efficiency
Agenda
Introduction Lighting Basics Lighting Best Practices Getting Your Project Started Summary
Lighting Basics
Photos courtesy of Lithonia Lighting, Grainger and Seagull Lighting
Lighting Efficiency Benefits
Energy savings = $ savings Reduced maintenance = time and cost savings Better light quality:
o Increased productivity o Improved safety and performance o Comfort
Basic Definitions
Lamp light bulb of any type
Luminaire complete lighting fixture including:
Housing Reflectors Wiring Trim Lens or shade Lamps Ballast Lamp holders
Lighting Types Incandescent
Filament heated by electric current to produce light
o Incandescent o Halogen advanced incandescent
Inefficient
o <10% energy consumed actually results in light output
(6%-7% per GE Lighting)
o >90% energy lost as heat o Legislation to ban these in U.S. by 2012 (2011 in CA)
Short lived filament burns up or breaks
Lighting Types Fluorescent
Luminescence excited electrons cause phosphors in lamp to glow:
Fluorescent lamps use phosphor coating to emit white light Linear light source provides even illumination Can be temperature sensitive Very wide offering of products
Lighting Types HID
High Intensity Discharge
Excited gasses discharge light Point source is easily controlled aimed accurately Not temperature sensitive (cold or warm)
Lighting Types HID (continued)
Types:
Metal halide standard, P.S. white light High pressure sodium amber light Mercury vapor bluish green white light Low pressure sodium yellow colored light, monochromatic
For 24/7 MH operation, shut down each week for 15 minutes safety concern!
Induction Lamps Early 90s
Alternative to low wattage HID lamps:
(street lighting retro-fits) Three system parts
o High frequency generator (2.65mhz) o Power coupler o Discharge vessel (lamp)
New technology?
55-400W Instant starting, 85 CRI 100,000 hours life, 65-70 LPW 3000oK, 3500oK, and 4100oK Excellent for difficult-to-access areas
Lighting Types LED
Light Emitting Diode
Very long life if heat is controlled, 50,000+ hours Efficiencies improving 130 LPW at LED, 70-80 LPW from fixtures Good color rendition, 85-90 CRI No UV in beam great for artwork, etc. Starting to work for exterior, low footcandle needed Coming of age in task lighting, downlights, etc. Still needs to improve for general indoor lighting
LED Canopy Lighting 2008
3 pump rows, 42 fixtures, 18 footcandles
LED Canopy Lighting 2009
5 pump rows, 30 fixtures, 80 footcandles
DOE Testing
4, T8 LED retrofit products not viable per DOE: Simply put, the 4 SSL linear replacement lamps do not provide sufficient light output or efficacy, have poorer color quality than fluorescent benchmarks, often require electrical rewiring of the troffer (to bypass the ballast), and do not represent wise use of SSL technology at this time.
CRI Color Rendering Index
How accurately a light source makes an object appear compared to natural or incandescent light. Rated on 1-100 scale (100 closest to natural light):
T12 fluorescent, 52 to 65 T8, T5 and CFL, 70 to 95 Standard MH, 55 to 65 Pulse start MH, 70 to 80 Ceramic PS MH, 80 to 94 LED, 85 to 90 HPS, 22 LPS, 0
Color Rendering Index
Color Accuracy
Ability of a light source to show colors realistically compared to how an object would appear in incandescent or natural light.
CRI = 90
CRI = 70
CRI = 50
CCT Correlated Color Temperature
Color Appearance
Describes appearance of the light itself
High pressure sodium 2200K Incandescent 2000-3000K Warm white fluorescent 2700K Neutral fluorescent 3500K Cool white fluorescent 4100K Metal halide 4200-5500K Average noon sunlight 4800K Daylight, fluorescent 5000K Uniform overcast skylight 7500K
Generally the higher the color temperature, the bluer the light appears.
Ballast What And Why
Ballast transformer to start/regulate fluorescent and discharge lamps Fluorescent ballast types:
o Heavy, hot o May be required in areas with equipment sensitive to high frequency (60Hz) o Instant start efficient, least expensive o Rapid and newer programmed start
Magnetic (core, coil)
Electronic
PS uses less Watts More gentle starting Use with sensors, frequent (200,000) on/offs
Photos courtesy of Advance Transformer and Universal Lighting Technologies
High Intensity Discharge Ballast Types
Standard probe start MH old technology Pulse start
o o o o Faster re-strike time Better maintained light level More lumens per watt Better color rendition
Electronic newer
o Even better LPW and maintenance-close to T8, T5HO o Pricing is coming down o Worth getting a quote to compare
Photos courtesy of Lithonia Lighting, Grainger, and Ruud Lighting
What Is Ballast Factor?
BF can be used to customize light level of T8 fixtures light output is proportional to specified BF design to meet light level needed:
Ultra low BF, less light and less energy Low BF, under-drives lamps for low light output Normal BF close to rated light output from lamps Medium BF cap a ballast lead for slight overdrive High BF, over-drives lamps for high light output .60 .77 .87 1.0 3L = 67 w 4L = 98 w 4L = 112 w 3L = 94 w
1.18 3L = 111 w
(Based on 32w T8s - 30w, 28w, 25w also available)
Calculating Electric Energy Consumption
Watts units of instantaneous power 1 kiloWatt (kW) = 1000 watts To calculate electricity consumption:
kWh of consumption = ( (# Fixtures x *input watts)/1000 ) X hours of operation *Find input watts in manufacturers catalogs!
Lighting Measurement Terminology
Lumens total light output from a lamp
o Listed by lamp manufacturers in catalog o Expressed as initial lumens or mean lumens o Lighting design targets mean lumens
Illuminance light level at the task
o Measured in footcandles by light meter or calculated with photometric data from manufacturer spec sheet
Footcandles (fc) light level at specific location
o Defined as a unit of illuminance equal to 1 lm/ft o Measured at task level o Both horizontal and vertical are important!
Recommended Light Levels
Illuminating Engineering Society of North America (IESNA) publishes guidelines (9th edition) based on 13 criteria 10th edition released mid 2011
o o o o Type of task being performed Size of objects handled Level of detail required Average age of workers in that space 30 fc 50 fc 100 fc
Recommended illuminance examples (IES RP7-01)
o Motor and equipment observation o Medium bench or machine work o Inspection (difficult)
More light needed for smaller size and lower contrast
o Adjust for age of worker, contrast, size
More Measurement Terminology
Efficacy lumens per watt (LPW)
o Measures lamp efficiency (like a cars MPG) o Varies by lamp type larger wattage is more efficacious o Good starting point, not only consideration look at total system performance for proper lighting solution for ambient temperature, fc required, dirt, glare, fixture optical performance
Lamp lumen depreciation/lumen maintenance
o As lamps age they give off less light o Follows a specific curve published for light sources by mfg. o Lumen depreciation differs by light source type
Picture used with permission from various lighting manufacturers and sources, including GE, Osram/Sylvania, IES, BOC,, and others.
Fixture Lumen Maintenance
Pulse start versus standard 400W MH
Graph and information courtesy of Ruud Lighting
Fixture Lumen Maintenance
Linear fluorescent
Graph and information courtesy of Ruud Lighting
Lamp Nomenclature
Varies by manufacturer Example F32T8/835
F = fluorescent 32 = lamp watts, sometimes length (i.e. F96T8 = 96) T = tubular shape 8 = diameter in eighths of an inch (T8 = 1 diameter) Usually followed by description of CRI & CCT
o CW = cool white (4100K) o SPX35, 835 = 85 CRI and 3500K
Sometimes followed by additional efficiency description
o WM = Watt Miser; SS = Super Saver; EW = Econo-Watt
Best Practices
Facility Lighting Level Standards
1. Identify current lighting equipment. 2. Interview workers in each area about light levels and effectiveness. 3. Determine existing light levels with light meter. 4. Establish standards using in-house information and industry standards IES. 5. Evaluate data for areas of potential lighting reduction/increase. 6. Use the standards when changing lighting, verify levels with light meter afterward. 7. Monitor light levels regularly to assess any degradation in levels.
Establish then verify/maintain
Lighting Level Standards (continued)
Resources available from IESNA
o RP-7, Recommended Practices for Lighting Industrial Facilities
($40) http://www.iesna.org/shop/item-detail.cfm?ID=RP-7-01&storeid=1 o AEDG-4-08, Advanced Energy Design Guide for Warehouses
http://www.iesna.org/shop/item-detail.cfm?ID=AEDG-4-08&storeid=1
Advanced Lighting Guidelines online subscription National Lighting Bureau (NLB) Guide to Industrial Lighting
o Download FREE .pdf at http://www.nlb.org/pubs/ o Download at http://www.algonline.org/
Properly Maintain Your Lighting System
Clean fixtures, lamps, lenses
o Dirt buildup traps light inside fixture o Same energy consumption, less light o Can lose 10-30%+
Inspect fixture components Institute group relamping program
o Replace lamps at 60-80% of rated life
New IES/NALMCO publication available RP-36-03 Planned Indoor Lighting Maintenance
http://webstore.ansi.org/RecordDetail.aspx?sku=IESNA/NALMCO+RP-36-03
High Bay Fixtures
Use with high efficiency T8 or T5 lamps, electronic ballasts, where appropriate
40-45% more efficient than T12 with magnetic ballasts, have higher quality light T12 4 and most 8 delisted on 7-14-12 Up to 50% more efficient than old HID but be careful! Payback in 3 years in long burn applications May not be appropriate for:
o Unheated spaces, cold warehouse, pools (caustic) o Extremely dirty, solvent, oily, dusty locations
Photos courtesy of Day-Brite Lighting, Orion Lighting, and Ruud Lighting
High Bay Fluorescent Can Work In
cold temperature environments
35oF room temperature
Before
After
High Bay Fluorescent Can Work In
swimming pools
Before
After
High Bay Fluorescent Can Work In
warehousing
Before
After
Pulse Start Metal Halide
Use pulse start metal halide where high bay fluorescent is not feasible.
Advantages over probe start MH:
Greater efficacy Better lumen maintenance Longer lamp life Better color rendition Faster warm up Quicker restrike Start in colder temps. vs. fluorescent Can save up to 80W+ per fixture, large variety of wattages, sizes. 400W to 320W, etc.
Pulse Start Metal Halide Example
Power plant
Before
After
Install Automated Controls
Ideal for areas where lighting might be left on when not in use Occupancy sensors can save up to 80%+ in energy costs Infrared, ultrasonic, dual technology, microphonic Dimming/daylighting controls can reduce energy costs, extend lamp life
Maximize Efficient Task Lighting
When upgrading lighting, maximize task lighting and minimize ambient or overhead put light where needed. Combination of area lighting and independently switched task lighting saves up to 20%.
Getting Your Project Started
Project Support
Program Ally listing on Focus on Energy website, www.focusonenergy.com Vendors for lighting, HVAC, motors, etc. Energy Advisors Focus on Energy has advisors available to assist with projects, 800-762-7077
Energy Advisor Support
Facility surveys identify technologies Savings estimates Project study support verify vendor proposal(s) accuracy Project incentive support Assist selling your project to management Specific Vendor Support picks up from Focus on Energy estimates to develop formal design/proposal
Selling Your Project Upstream
Simple payback analysis basic approach Lifecycle cost benefit analysis comprehensive approach addressing all project benefits
o Capital cost o Energy savings o Correcting, improving light levels o Maintenance cost o Depreciation o Other cost, savings streams o Tax deduction opportunities EPAct 2005 o Capital cost o Energy savings
EPAct 2005
Energy Policy Act of 2005 Signed into federal law August, 2005 Effective 1-1-05 through 12-31-13 Numerous provisions for energy efficiency Higher standard for lighting, HVAC and building envelope technologies Tax deductions for implementation includes language for tax exempts to benefit
Tax Deduction Financial Impact
Based on ASHRAE 2001 standard:
Full building envelope measures can generate up to $1.80/ sq. ft. tax deduction. Interim lighting rules allow for $.30-.60/sq. ft. tax deduction based on 25%-40% improved efficiency. 200,000 sq. ft. lighting project can generate up to $120,000 lighting tax deduction.
Focus on Energy Lighting Incentives
Provide cash back incentives for eligible customers and projects www.focusonenergy.com/financialincentives Primarily granted on a per fixture basis (prescriptive) Custom grants available for new construction projects, cutting edge technology:
o Energy saving projects that dont fit prescriptive o Requires pre-approval by program management
Typical Incentives*
Existing Equipment HID (400W) HID (400W) HID (400W) 2 lamp T12 HO or 2 lamp T12 VHO Installed Measure High bay 6T8 or 4T5HO High bay T8 or T5 w/sensor controls Pulse start MH 320W w/electronic ballast 4 lamp HPT8 components Incentive/ Unit $50 $65 $50 $20 $40
* through March 31, 2012
Practical Energy Management (PEM)
Understand how your facility uses energy Develop skills necessary to manage energy usage, cost Half-day training dates For future Industrial Practical Energy Management training dates, check the Focus website at www.focusonenergy.com/training
Building Operator Certification
Understand how your facility systems interact Develop the skills necessary to manage energy usage, identify upgrade opportunities Level II advanced equipment troubleshooting and diagnostics plus facilities management training Level II offered March 1, 2012 7 full day training sessions, once per month Offered at 4 videoconference locations Chippewa Falls, Green Bay, Madison, Mequon Covers facility preventive maintenance and troubleshooting, advanced electrical diagnostics, HVAC troubleshooting and maintenance, HVAC controls and optimization, introduction to building commissioning, and enhanced automation and demand reduction Check the Focus on Energy for upcoming series dates
Get Your Project Started!
Contact your Energy Advisor or Program Ally; ask about technical support and incentives for eligible projects. Dont have an Energy Advisor? Contact Focus on Energy, 800-762-7077, for more information.
Summary
Understand lighting technology, terminology Implement lighting best practices to maximize return on your investment Work with Focus on Energy and qualified Program Allies to make your energy efficiency projects happen
Additional Resources
Lightsearch.com: useful formulas, economics, etc. www.lightsearch.com/resources/lightguides/index.html IESNA website: www.iesna.org Lighting Design Lab: www.lightingdesignlab.com Federal Energy Management Program (FEMP): www1.eere.energy.gov/femp/ and www1.eere.energy.gov/industry/bestpractices/ National Lighting Product Information Program: www.lrc.rpi.edu/programs/NLPIP/publications.asp
Additional Resources (continued)
Designlights Consortium: www.designlights.org/downloads/highbay_guide.pdf NEMA tax incentive information: www.lightingtaxdeduction.org/ Focus on Energy fact sheets www.focusonenergy.com/Information-Center/
Another Resource
Randy Johnson, LC, President US Lamp, Inc. 920-434-3636 [email protected]
Thanks for participating!
Focus on Energy Industrial Program
Thank you to the following companies for the use of their photos: GE Lighting, Philips Lighting, Osram/Sylvania Lighting, US Lamp, Inc., TCP, Seagull Lighting, Orion Lighting, Lithonia, Grainger, Ruud Lighting, Holophane, Hubbell Lighting, Lutron, WattStopper, Maxlite, Joseph Coates, and Energy Star