50% found this document useful (2 votes)
2K views

Design of Two Way Slab by IS 456

This document summarizes the design of a two-way slab with a shorter span of 5 meters and longer span of 5.76 meters. It includes the grade of concrete and steel used, loading conditions, reinforcement details, and deflection checks. The slab thickness is 150 mm with M20 grade concrete and Fe415 steel reinforcement. Reinforcement is #8 bars spaced at 250 or 500 mm. Deflection checks confirm the span-to-depth ratio satisfies code requirements.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
50% found this document useful (2 votes)
2K views

Design of Two Way Slab by IS 456

This document summarizes the design of a two-way slab with a shorter span of 5 meters and longer span of 5.76 meters. It includes the grade of concrete and steel used, loading conditions, reinforcement details, and deflection checks. The slab thickness is 150 mm with M20 grade concrete and Fe415 steel reinforcement. Reinforcement is #8 bars spaced at 250 or 500 mm. Deflection checks confirm the span-to-depth ratio satisfies code requirements.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 8

Date : 8/Sep/03 CONTROL ROOM AT VAPI FIRST SLAB LEVEL Design of Two way slab marked : General Data

Grade of Concrete Grade of Steel Density of Concrete Shorter Span of slab Lx Longer Span of Slab Ly Ly/Lx Edge condition (Panel) : S3 = = = = = M20 Fe415 25 3 5 ( 20 ( 415 kN/m3 m m N/mm2 ) N/mm2 )

= 1.666667 . 5 Two Short Edges Discontinuous = = 140 15 mm mm

Trying and adopting Thickness of slanb Clear Cover to reinforcement Loading on Slab Dead Load - Self Weight ( 0.14 x 25 ) - Floor Finish load - Other Dead Load Live Load Total Design Load

= = = = =

3.5 1

kN/mm2 kN/mm2 kN/mm2 kN/mm2 kN/mm2

5 9.5

Along Short Span Moment coefficient a Mu = 1.5 ( a x w x Lx2) Effective Depth K = Mu/bd2 Pt of steel required Area of Steel Required Ast min @ 0.12 % Midspan 0.047667 6.11325 121 0.418 0.124 150 168 #8 250 mm c/c Support 0.063333 8.1225 121 0.555 0.165 199 168 #8 250 mm c/c #8 500 mm c/c 301.59 0.2493

Along Long Span Midspan 0.035 4.48875 117 0.328 0.098 115 168 #8 250 mm c/c Support 0 0 117 0.000 0.006 7 168 #8 250 mm c/c #8 500 mm c/c 301.59 0.2578

Provide Dia. And Spacing as (# indicates HYSD Bar) Extra top

Area of Steel Provided Pt. Provided

201.06 0.1662

201.06 0.1718

Date : 8/Sep/03 CONTROL ROOM AT VAPI FIRST SLAB LEVEL DEFLECTION CHECK :- (REF. CLAUSE 23.2.1 OF IS:456) Basic Allowable 'Lx/d' ratio without modification Steel Stress of Service Loads is given as fs = 0.58.fy [ Ast / Ast(pr.) ] Modification factor as per SP:24 (Clause 22.2) 1 0.225+0.00322.fs-0.625 log10(bd/Ast(pr)) Permissible 'Le/d' ratio with modification factor Actual Span/Depth ratio, Lx / d = = = = = 26 180.12 N/mm2 1 0.317827 = 2 2.0000 52.000

( subjected to max MF=2

26.000 x 24.793 <

= 52.000 HENCE O.K.

REFERENCES :1) IS:456 (CODE OF PRACTICE FOR PLAIN AND REINFORCED CONCRETE 2000)

A) TABLE : 26 BENDING MOMENT COEFFICIENT FOR RECTANGULAR PANELS SUPPORT ON FOUR SIDES WITH PROVISION FOR TORSIONAL REINFORCEMENT. B) CLAUSE 26.5.2.1 FOR MINIMUM REINFORCEMENT IN SLABS 2) SP:16 (DESIGN AIDS FOR REINFORCED CONCRETE TO IS:456 - 1978) CHART:22 CONTROL OF DEFLECTION (PAGE NO. 44) EFFECTIVE DEPTH CALCULATION :ASSUMED OVERALL DEPTH CLEAR COVER TO REINF. MAXIMUM BAR SIZE EFF. DEPTH FOR MAIN REINF. EFF. DEPTH FOR SEC. REINF. = = = = = = = 140.00 mm 25.00 mm 10.00 mm 140.00 110.00 110.00 100.00 mm mm 25.00 10.00

3)

MATERIALS USED :1) 2) GRADE OF CONCRETE GRADE OF TOR STEEL = = M20 Fe415

1)

DESIGN OF SLAB MARKED :

TS1, TS22

THICKNESS =

DATA AVAILABLE :SPAN ALONG SHORTER SIDE, Lx SPAN ALONG LONGER SIDE, Ly RATIO OF SPANS, Ly / Lx CONTINUITY ALONG PERIPHERY DEAD LOADS :a) Self weight of slab b) Floor-finish + Water-proofing = = 0.140 x (assumed) 2550 = = = = = = 5.230 m c/c. & = 5.760 m c/c. & = 1.1060 TWO ADJACENT EDGES DISCONTINUOUS

c) False Ceiling LIVE LOADS :a) Considering accessible roof THUS TOTAL LOADS, w

50.00

= =

DESIGN PARTICULARS

ALONG Lx MID-SPAN SUPPORT

a) b) c) d) e) f) g) h)

Coefficient (IS456) Mu = 1.5 (.w.Lx.Lx) Effective depth, d in mm K = Mu / b.d.d in N/sqmm. Percentage of Reinf. 'pt' Area of Reinforcement 'Ast' 'Ast' minimum @ 0.12% Provide dia. & spacing as (T indicates HYSD bars - Fe415 gr.) Area of Steel provided, Ast(pr.) pt (pr.) = 100 Ast(pr.) / b.d

0.0403 1375.70 110 1.1369 0.3439 378.33 168.00 T 10.00 @ 140.00 mm c/c 561.00 0.5100

0.0534 1822.88 110 1.5065 0.4663 512.94

i) j)

DEFLECTION CHECK :- (REF. CLAUSE 23.2.1 OF IS:456) Basic Allowable 'Lx/d' ratio without modification Steel Stress of Service Loads is given as fs = 0.58.fy [ Ast / Ast(pr.) ] Modification factor as per SP:24 (Clause 22.2) 1 = = = 26 162.32 N/mm2 1 =

0.225+0.00322.fs-0.625 log10(bd/Ast(pr)) Permissible 'Le/d' ratio with modification factor Actual Span/Depth ratio, Lx / d

= = =

0.564915945 26.000 x 45.455 <

ONCRETE 2000)

NGULAR PANELS SUPPORTED NFORCEMENT.

10.00 /

2.00

140.00 MM

5.000 m clear 5.530 m clear

ES DISCONTINUOUS

357.00 Kg/m2 275.00 Kg/m2

50.00 Kg/m2 682.00 Kg/m2

150.00 Kg/m2 832.00 Kg/m2

ALONG Ly MID-SPAN SUPPORT

0.0350 1194.77 100 1.1948 0.3626 362.61 168.00 T 10.00 @ 200.00 mm c/c 392.70 0.3927

0.0470 1604.41 100 1.6044 0.5000 500.03

N/mm2 1.7702

1.7702 46.025

= 46.025 HENCE O.K.