100% found this document useful (2 votes)
457 views1 page

Bracket - 4 Design

This document provides design details for a bracket for the 4th floor of Brigade Mall project. Key details include: - The bracket is designed to support a factored load of 927 kN applied 800 mm from the column face. - The column has a width of 1200 mm, depth of 250 mm, and maximum shear stress capacity of 3.125 N/mm2. - Calculations are shown to check that the section can be designed as a bracket, and to calculate lever arm, depth of neutral axis, and tension steel requirements. - Reinforcement details are provided, including a minimum of 0.4% compression steel and 6 bars of 10 mm diameter tension steel spaced at 125 mm

Uploaded by

bjreddy
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
457 views1 page

Bracket - 4 Design

This document provides design details for a bracket for the 4th floor of Brigade Mall project. Key details include: - The bracket is designed to support a factored load of 927 kN applied 800 mm from the column face. - The column has a width of 1200 mm, depth of 250 mm, and maximum shear stress capacity of 3.125 N/mm2. - Calculations are shown to check that the section can be designed as a bracket, and to calculate lever arm, depth of neutral axis, and tension steel requirements. - Reinforcement details are provided, including a minimum of 0.4% compression steel and 6 bars of 10 mm diameter tension steel spaced at 125 mm

Uploaded by

bjreddy
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PROJECT NAME: DESIGNED: 4TH FLOOR

BRIGADE MALL
SRIDHAR CHECKED: BRACKET NUMBER:
kN mm mm mm N/mm2 mm

DATE:

13-05-2013 HNP BRTK- 4

Fctored load Width Overall Depth

Pu b D

= = = = = =

927 800 1200 250 3.125 1150

Materials fy N/mm2 = 500 fck N/mm2 = 25 Here av/d = 0.217 <1


COLUMN

av

Distance b/w col. face to load av Maximum shear stress cmax Effective depth d

BRACKET

Hence design as BRACKET

Calculate Z & Xu:


m = P/(0.889*fck*b*d) =
2

n = av/d
(Z/d) - (n/(m+n))(z/d)+(m/(m+n))n
2

Lever arm Z Depth of N.A. Xu = 2.22(d-Z) Limiting value Xumax = 0.46d Here Xu < Xumax Under reinforced section; Provide Minimum Compression Steel.

= = = = =

0.0453 0.2174 0 940 466 529

mm mm mm

Percentage of steel required Pt = Here Pt < 0.4%; Hence Provide Minimum 0.4%. Pt min = But Here, Take = Provide Ast Provide Dia 20 mm; No's = = Hence provided Ast = Percentage of steel Pt

0.116 0.2 1840 5.855 1886 0.205 943

% %
mm2

Say 6 No's
mm2 % mm2

Computation of Horizontal steel:


Ash = 0.5 Ast =
kN kN kN

Computation of Tensile force T:


Tactual = P(av/Z) Tmin = 0.5 P Here Tact < Tmin; T = = = 247 464 464

Provide Dia 10 mm; No's = 6.000 Say 6 No's Spacing S = (2/3)d/No's = 125 mm Provide 6 No's 2-Legged links of 10mm dia in upper 2/3 depth or 765mm

Computation of Tensile steel Ast:


Strain in steel corresponding to maximum strain of 0.0035 in concrete = 0.004109 es = 0.0035(d-Xu)/Xu Maximun strain in tension reinforcement @ failure = 0.004174 esmax = (fy/1.15Es)+0.002 Here es < esmax Hence Ok N/mm2 = 435 Stress in steel fs = 0.87fy mm2 = 1066 Area of steel required Ast = T/fs

Check for vertical shear:


From SP:16, Cl.4.1, beta Design shear stress c Enhanced shear ce = c(2d/av) Here ce < cmax Shear capacity Vu = ce bd Actual shear stress v = P/bd Here v <
ce

= 14.162 N/mm2 = 0.334 = 3.076 N/mm2 Hence take ce = 3.076 N/mm2 = 2830 kN = 1.008 N/mm2 Hence SAFE in shear.