0% found this document useful (0 votes)
315 views

18 BL PDF

This document provides information on meters and instrument transformers including: - A selection guide for three-phase metering systems including socket, bottom connected, and switchboard type meters. - Tables listing current and voltage instrument transformers for 600V and 2.5-69kV applications with information on product numbers, ratings, and specifications. - Reference publications for additional technical information on the products described.

Uploaded by

Richard Regidor
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
315 views

18 BL PDF

This document provides information on meters and instrument transformers including: - A selection guide for three-phase metering systems including socket, bottom connected, and switchboard type meters. - Tables listing current and voltage instrument transformers for 600V and 2.5-69kV applications with information on product numbers, ratings, and specifications. - Reference publications for additional technical information on the products described.

Uploaded by

Richard Regidor
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Meters and Instrument Transformers

Section 19

Three-Phase Metering ...............................................................19-2


Instrument Transformers, 600 Volt.........................................19-4
Instrument Transformers, 2.5-69 kV.......................................19-5

Reference Publications
V-60 Polyphase Meters
Polyphase Switchboard Meters
KV Switchboard Meter
KV RSX RS232/RS485 Comm Option
Instrument Transformer Buyers Guide
KV2 Features
KV2 Instructions
KV2 Brochure
KV2C Instructions
KV2C Features
KV2C Brochure
I-210 Brochure
I-210 Instructions

GEH-2758
GEH-2762
GEH-7271
GEH-7275
GEP-9186
GEH-7278
GEH-7277
GEA-12616
GEH-7285
GEH-7285A
GEA-13371
GEA-13391
GEH-7287

Publications and Reference: See Section 22 for a


complete list of additional product-related publications

Rev. 1/08

Prices and data subject


to change without notice

www.geelectrical.com

BuyLog Catalog

19-1

Meters and Instrument Transformers

Section 19

Three-phase Metering
Selection Guide for Socket, Bottom Connected and Switchboard Type.
To Select the Optimum Metering System:
1. Determine the circuit type and voltage
2. Compute or estimate the served load in amperes and select metering equipment from
the chart below and order as "Sim. To" Except: Current and Voltage Ratio.

I-70S Single Phase (Electro-Mechanical Meters)


Meter Class S-Base
(Socket-Type)
TR
SC

Application

Meter
Type

Pulse
Initiator

Energy EM

170

F52 Pointer
F86 Cyclometer

N/A

10

Energy SS

I-210

Solid State

N/A

20

Register

ANSI Forms
TR
SC

100
200
320
100
200
320

3S, 4S

1S, 2S

3S, 4S

1S, 2S

Electronic KV2C Meters (Wide Range 120-480V Single and Three PhaseAll Functions)

Application

Meter
Type

Register

Pulse
Initiator

All

kV

kV2C

Option

Meter Class
S-Base
(Socket-Type)
TR
SC
20

Meter Class A-Base


(Bottom Connected
Surface Mounted)
TR
SC

200, 320

20

150

Switchboard
Type TP

Optocom.
Com. Part

Com. Outputs/Options

Programming
Software

Software

kV

Yes

Modem and RS232/485

MeterMate

MV90

KV2C Electronic Demand Meter2


Circuit
Type

Circuit
Voltage

Amps

ANSI
C12-10 Form

No.of
Jaws

120/208Y

0-200

16S

277/480Y

0-200

16S

34WY

Self

120/280Y

0-200

16S

277/480Y

0-200

16S

Contained
3W Network

120/208 Network
240

0-200
0-200

12S
12S

5
51

33W
480
120/208Y
277/480Y

0-200
0-10
0-10

12S
36S
36S

51
13
13

34WY
120/208Y
Transformer

277/480Y

0-10
0-10

9S
9S

13
13

Rated
3W Network

120/208 Network
240

0-10
0-10

45S
45S

8
8

33W
480

0-10

45S

Interval
(Min.)

Meter Programmed
with Demand Product No.

Programmed with Demand


and Pulse3 Product No

15

784X400030

784X401016

30

784X400031

784X401017

15

784X400030

784X401016

30

784X400031

784X401017

15

784X400030

784X401016

30

784X400031

784X401017

15

784X400030

784X401016

30

784X400031

784X401017

15

784X100014

784X101011

30

784X100015

784X101012

15

784X100014

784X101011

30

784X100015

784X101012

15

784X100014

784X101011

30

784X100015

784X101012

15

784X6000154

784X6010114

30

784X6000164

784X6010124

15

784X6000154

784X6010114

30

784X6000164

784X6010124

15

784X9000284

784X9010154

30

784X9000294

784X9010164

15

784X9000284

784X9010154

30

784X9000294

784X9010164

15

784X5000174

784X5010104

30

784X5000184

784X5010114

15

784X5000174

784X5010104

30

784X5000184

784X5010114

15

784X5000174

784X5010104

30

784X5000184

784X5010114

1If line 2 is grounded, a socket having the line 2 connector attached directly to the socket case may be used.

If line 2 is not grounded, a socket with the line 2 connector insulated from the case must be used to avoid inadvertent grounding of line 2.
2kV meter is wide ranging for voltage and automatically adjusts for circuit voltage listed.
3Pulse output for kV meter self contained is 10 Wh per pulse. Pulse output for kV meter transformer is 1 Wh per pulse.
4For switchboard order "Sim. To" except: Switchboard Type.

19-2

BuyLog Catalog

www.geelectrical.com

Rev. 1/08

Prices and data subject


to change without notice

Meters and Instrument Transformers

Section 19

600 Volt Instrument Transformer Type Selection Chart


Voltage Transformer JVA-O 600 Volt
Voltage

Product Number

120:120
240:120
288:120
480:120

760X034001
760X034002
760X034004
760X034006

Current Transformer JAK-O 600 Volt


Window-Type, Single-Ratio
Current Ratio (in Amps)
Pri:Sec

Continuous Thermal Current Rating Factor


30C Ambient

55C Ambient

Window
Size

Product Number
With Low Base

3.0
4.0
3.0
2.0
2.0

2.9
2.9
2.4
1.8
1.5

2.500
3.062
3.062
3.062
3.062

750X033311
750X033313
750X033314
750X033315
750X033316

200:5
400:5
500:5
600:5
800:S

Type JAK-O Current Transformer

Current TransformersBar Types


400-5 Rating1
Ratio Range

Type

Product
Service

Min.

Max.

JCT-0
JCM-0
JKM-0
JAM-0
JCL-0

750X023
750X025
750X041
750X021
750X028

200
200
10
100
1200

800
400
1200
400
4000

Window
Diameter Rating
inches
Factor
Bar
Bar
Bar
Bar
-

2.0
2.0
1.5
1.2

1500-5 Rating1

Acc'y. @
Meter
Relay
Burden2 Burden2 Lbs.
.3 B0.2
.3 B0.5
.3 B0.5
.3 B0.2

T50

6
6
15
15
25

Window
Diameter Rating
inches Factor

Acc'y @
Meter
Burden2

Relay
Burden2

Option/
Other

Closest Known Competitor Type


ABB

ITI

CBT
CBH

1.5

.3B2

Sch.

TCB
TAB

R6BA
R6B

250/251
252

For 2W Meter
Bar

Durh.

C130

Current TransformersWindow Type with Mounting Base


400-5 Rating1
Ratio Range

Type

Product
Service

Min.

Max.

JCR-0
JCW-0
JAK-0
JAL-0
JCP-0
JAF-0
JCS-0

750X034
750X032
750X033
750X035
750X015
750X0103
750X0100

100
200
200
200
600
100
50

400
400
800
400
4000
3000
4000

Window
Diameter Rating
inches
Factor

1500-5 Rating1

Acc'y. @
Meter
Relay
Burden2 Burden2 Lbs.

2.00
2.00
3.00
2.38

2.0
2.0
4.0
2.0

.3 B0.2
.3 B0.5
.3 B0.5
.3 B0.5

4.50
4.88

1.3
2.0

.3 B0.1
.3 B0.1

C50
C50

3
4
9
7
28
26
28

Window
Diameter Rating
inches Factor

5.37
5.37
5.37

2.0
1.3
1.5

Acc'y @
Meter
Burden2

.3 B2
.3 B2
.3 B2

Relay
Burden2

Option/
Other

C200
C100
C200

Dual Ratios
Burial Type
Dual Ratios
Dual Ratios
Dual Ratios

Relay
Burden2

Option/
Other

Closest Known Competitor Type


ABB

ITI

CSE
CSH
CMF

Durh.

Sch.

TCW
TFW
AB

R6SA
R6S
R6M

RLC

Current TransformersRectangular Types with Mounting Holes


400-5 Rating1

Type

Product
Service

JCH-0
750X012
JCH-0C 750X112
JAH-0 750X0140
JAS-0
750X0141
JCB-0
750X011
JCB-0C 750X111
JAG-0
750X010
JAG-0C 750X110
JAG-0C3 750X110
JAD-0
750X020
JCD-0
750X031
JAB-0
750X036

Ratio Range
Min.

Max.

100
50
400
150
400
50
100
50
50
200
1500
200

800
2000
4000
2000
6000
6000
3000
5000
4000
4000
8000
3000

Window
Diameter Rating
inches
Factor

1500-5 Rating1

Acc'y. @
Meter
Relay
Burden2 Burden2 Lbs.

2.50
1.5/2.5
4.00
4.00
8.12
7.36
6.50
6.50
6.50
5.75

1.3
1.3
1.3
1.3
1.5
1.3
4.0
3.0
3.0
4.0

.6 B0.2
.3 B0.5
.6 B0.2
.6 B0.2
.6 B0.1
.3 B0.9
.3 B0.2
.3 B0.2
.3 B0.5
.3 B0.2

3.5/4.5

4.0

.3 B0.2

C35
C10
C100
C55
C55
C100

4
3
9
8
20
48
25
21
38
13
20
7

Window
Diameter Rating
inches Factor
2.50
5.75
4.00
8.12
7.36
6.50
6.50
6.50
5.75
8.12
3.5/4.5

1.3
1.3
1.3
1.5
1.3
2.0
2.0
1.5
3.0
3.0
2.0

Acc'y @
Meter
Burden2
.3 B1.8
.3 B1
.3 B2
.3 B1
.3 B1.8
.3 B2
.3 B1.8
.3 B1.8
.3 B1
.3 B1
.3 B1

Opt Mtg Bkts


Opt Mtg Bkts
C50
C50
C100
C400
C200
C200
C400

Mul Ratio
High Relay Types
Mul Ratio
Mul Ratio
Mul Ratio
Dual Ratios
Dual Ratios
Opt "Grabbers"

Closest Known Competitor Type


ABB
IMC
IMC
SCN/SCL
SCH-5/SCG-4
SCP-3
SCD-3
SCV
SCV
SCV-D
CLC/RLC/SCL
CLE
CMV

ITI

Durh.

180
120/130/100
110/115
149
143
780/781
780/781
785/786
120/130
AD
149
ACL
AP

Sch.

R6L
R6P

1Multiply primary amps by rating factor to get max. amp rating at 30C.
2Performance and characteristics can vary with ratio/features.
3High Relay-Double Wide

Note: "C" types are case designs (indoor).

Publications and Reference: See Section 22 for a


complete list of additional product-related publications

Rev. 1/08

Prices and data subject


to change without notice

www.geelectrical.com

BuyLog Catalog

19-3

Meters and Instrument Transformers

Section 19

600 Volt Instrument Transformer Type Selection Chart


Current TransformersAuxiliaryUse in Sec. Of Main CT to change ratio5A Primary
400-5 Rating1
Ratio Range

Type

Product
Service

Min.

Max.

JAR-0

750X001

0.1

15

Window
Diameter Rating
inches
Factor
Wound

1500-5 Rating1

Acc'y. @
Meter
Relay
Burden2 Burden2 Lbs.

1.5

.3 B0.2

Window
Diameter Rating
inches Factor

Acc'y @
Meter
Burden2

Relay
Burden2

Option/
Other

12

Closest Known Competitor Type


ABB

ITI

AUX/CT

188

Durh.

Sch.

Current TransformersIndicating Instrument Window Types1.5% Error @ Rated


400-5 Rating1
Ratio Range

Type

Product
Service

Min.

Max.

JAI-0
JAU-0

750X093
750X091

50
50

800
800

Window
Diameter Rating
inches
Factor
1.75
1.75

1500-5 Rating1

Acc'y. @
Meter
Relay
Burden2 Burden2 Lbs.

1.5
1.5

2.5VA
2.5VA

Window
Diameter Rating
inches Factor

Acc'y @
Meter
Burden2

Relay
Burden2

0.5
0.5

Option/
Other

Closest Known Competitor Type


ABB

Term. Screws
With Leads

ITI

Durh.

Sch.

__ __ RT
__ __ RL

Voltage Transformers
Type

Product
Service

JEP-0C
JVA-0
JVP-1
YT-1557

760X135
760X034
761X030
760X099

Closest Known Competitor Type


Accy Class

Burden

Thermal

Lbs.

Fuse Option

ABB

ITI

Durh.

Sch.

0.3
0.3
0.3

W
M
Y

300VA
500VA
750VA
300VA

12
16
30
50

No
Yes
Yes
No

PPW
PPM
PPM
PPI

460/470
456
456
450

DF
DB
DB
DA

T5R
T6R
T6R
T7R

1Multiply primary amps by rating factor to get max. amp rating at 30C.
2Performance and characteristics can vary with ratio/features.

Note: "C" types are case designs (indoor).

19-4

BuyLog Catalog

www.geelectrical.com

Rev. 1/08

Prices and data subject


to change without notice

Meters and Instrument Transformers

Section 19

2.5-69 kV Instrument Transformer Selection Chart


Indoor Current Transformers

Type
JKM-2
JCM-2
JKC-3
JKM-3
JKS-3
JCM-3
JCB-3
JCM-4
JKM-4
JCB-4
JKS-5
JKM-5
JCM-5
JCB-5

Design
Wound
Wound
Wound
Wound
Wound
Bar
5.5' Win.
Bar
Wound
5.5' Win.
Wound
Wound
Bar
5.5' Win.

Volts
2500
2500
5000
5000
5000
5000
5000
8700
8700
8700
15000
15000
15000
15000

BIL
45
45
60
60
60
60
60
75
75
75
95
110
110
110

0.3 Accy
at Meter
Burden
B-0.5
B-2
B0.5
B-2
B0.1/2
B-2
B-2
B-2
B-2
B-2
B0.1/2
B-2
B-2
B-2

Most Single Ratio


Max1
Relay
Amps
Class
at R.F.
T50
600
C200
4000
T50
1200
T100
1000
T10/100
1200
C200
4000
C200/400
5300
C200
4000
T100
1000
C200/400
5300
T10/200
1200
T200
1200
C200
4000
C200/400
5300

Max.
1200
4000
1200
800
800
4000
4000
4000
800
4000
800
800
4000
4000

Major2
30C Rating
Factor
1.5
1.3
1.5
1.5
1.5
1.3
1.3
1.3
1.5
1.3
1.5
1.5
1.3
1.3

Avg
Lbs.
15
35
15
29
30
62
85
62
29
85
50
47
95
110

Creep
(Inches)

11

Tap Sec.
Tap, Dual Sec.
Tap, Dual Sec.
Tap Sec.
Tap Sec.

Max.
800
4000
4000
4000
800
4000
1200
4000
800
4000
800
3000
800
3000
3000
3000

Major2
30C Rating
Factor
1.5
1.3
1.3
1.3
1.5
1.3
1.5
1.3
1.5/3
1.3
1.5/3
1.5/2
3
2
2
2

Avg
Lbs.
38
110
95
95
38
110
60
135
35
115
77
320
70
345
540
590

Creep
(Inches)

Other/
Options

Primary
Min.
10
600
10
5
15
1200
1200
1200
10
1200
15
5
1200
1200

Other/
Options

ABB
Type

Closest Competitor Type


ABB
ITI
OIL Type
Type

Tap, Dual Sec.


Tap, Dual Sec.
Tap Sec.
Tap Sec.
Tap Sec.

8
9

KIN-60
KIR-60

CTWH-3-60-T50
CTWH-3-60-T100

KIR-75

CTWH-4-75-T100

KIR-11

CTWS-5-110-T20
CTWH-5-110-T200

Outdoor Current Transformers

Type
JKW-3
JCD-3
JCW-3
JCW-4
JKW-4
JCD-4
JKW-5
JCD-5
JCK-5
JCW-5
JKW-6
JKW-150
JKW-7
JKW-200
JKW-250
JKW-350

Design
Wound
5.5' Win.
Bar
Bar
Wound
5.5' Win.
Wound
5.5' Win.
Wound
Bar
Wound
Super-Bute
Wound
Super-Bute
Super-Bute
Super-Bute

Volts
5000
5000
5000
8700
8700
8700
15000
15000
15000
15000
25000
25000
34500
34500
46000
69000

BIL
60
60
60
75
75
75
110
110
110
110
150
150
200
200
250
350

0.3 Accy
at Meter
Burden
B-2
B-2
B-2
B-2
B-2
B-2
B-2
B-2
B0.5
B-2
B-2
B-2
B0.5
B-2
B-2
B-2

Most Single Ratio


Max1
Relay
Amps
Class
at R.F.
T100
1000
C200/400
5300
C200
4000
C200
4000
T100
1000
C200/400
5300
T100/200
1200
C200/400
5300
C20
1200
C200
4000
T100/200
1200
T200/800
4000
1200
T200/800
4000
T200/800
4000
T200/800
4000

Primary
Min.
5
1200
1200
1200
10
1200
5
1200
5
1200
5
25
10
25
25
25

Tap, Sec.
Tap, Sec.
Tap, Sec.

19
13.5

Tap, Sec.
Tap, Sec.
Tap, Sec.

15
24
25
26
35
48
64

Tap, Sec.
Tap, Sec.
Tap, Dual Sec.
Tap, Sec.
Tap, Dual Sec.
Tap, Dual Sec.
Tap, Dual Sec.

Closest Competitor Type


ABB
ABB
ITI
Type
OIL Type
Type
KOR-60
KOT-60
KOT-60
KOT-75
KOR-75
KOT-75
KOR-11
KOT-11
KON-11
KOT-11
KOR-15&B
KOTD-150
ICT see below
KOR-20
KOTD-200
ICT C200/100
RF 1.5/1

1Multiply primary amps by rating factor to get max amp rating at 30C.
2Rating factor can vary with ratio.

Publications and Reference: See Section 22 for a


complete list of additional product-related publications

Rev. 1/08

Prices and data subject


to change without notice

www.geelectrical.com

BuyLog Catalog

19-5

Meters and Instrument Transformers

Section 19

2.5-69 kV Instrument Transformer Selection Chart


Indoor Voltage Transformers

Type
JVM-2
JVM-3
JVM-4
JVM-5
JVM-6

Design

Volts
2400
4800
7200
14400
24000

0.3 Accy
at Meter
BIL
Burden
45
Y
60
Y
75
Z
95/110
Z
125
Y

Most Single Ratio


Max1
Relay
Amps
Class
at R.F.
750
750
1500
1500
750

Major2
30C Rating
Max.
Factor
2400
4800
7200
14400
24000

Primary
Min.
2400
4200
7200
12000

Avg
Lbs.
30
30
85
85
100

Creep
(Inches)

Other/
Options
Fuse Option
Fuse Option
Fuse Option
Fuse Option

Creep
(Inches)

24000

Avg
Lbs.
44
105
105
105
74
95
105

24000

140

24000
14000
34500
20125

225
230
140
140

34500
20125
27600
46000
40250
69000

235
240
420
520
430
560

Other/
Options3
2 Bushing
2 Bushing
1-2 Bushing
1-2 Bushing
1 Bushing
1 Bushing
1-2 Bushing
2 Bushing
2 Bushing
1 Bushing
2 Bushing
2 Bushing
1 Bushing
2 Bushing
1 Bushing
2 Bushing
1-2 Bushing
2 Bushing
1 Bushing
1 Bushing
2 Bushing
1 Bushing
2 Bushing

Closest Competitor Type


ABB
ITI
OIL Type
Type
PT3-45
VIY-60
PT3-60
VIZ-75
PT4-75
VIZ-11
PT5-110
VIZ-12.5
PT6-125
ABB
Type

Outdoor Voltage Transformers

Type
JVW-3
JVW-4
JVW-5
JVW-110
ABB ref
JVW-6
JVW-6
ABB ref
JVW-150
ABB ref
ABB ref
JVT-150
JVS-150
JVW-7
JVW-7
ABB ref
ABB ref
JVT-200
JVS-200
JVS-250
JVT-250
JVS-350
JVT-350

Design

Super-Bute
Super-Bute

Super-Bute
Super-Bute
Super-Bute
Super-Bute
Super-Bute
Super-Bute

Volts
4800
7200
14400
14400
14400
14400
24000
24000
24000
24000
34500
24000
14400
34500
20125
34500
36000
34500
20125
27600
46000
40250
69000

BIL
60
75
110
110
110
125
125
150
150
150
150
150
150
150
200
200
200
200
200
250
250
350
350

0.3 Accy
at Meter
Burden
Y
Z
Z
Y
Z
Y
Y
Z
Y
ZZ
Z
ZZ
ZZ
Y
Y
Z
Y
ZZ
ZZ
ZZ
ZZ
ZZ
ZZ

Most Single Ratio


Max1
Relay
Amps
Class
at R.F.
750
1500
1500
1000
1500
750
750
2000
750
2000
2000
3000
3000
750
750
2000
1000
3000
3000
5000
4500
5000
4500

Major2
30C Rating
Max.
Factor
4800
7200
14400
14400
8400

Primary
Min.
2400
2400
7200
7200
7200
12000
12000
12000

23000

27600

19.6
19.6
19.6
21
21
27.2
26
27.5
26.1
27
27
26
27
27.2
37.5
36
36
50
52
64
66

Closest Competitor Type


ABB
ABB
Type
OIL Type4
VOY-60
VOZ-75
VOZ-11
VOY-11
VOZ-11M
VOG-12
VOY-12
VOZ-15
VOY-15
Y, 27", 1kVA
VOG-15
VZ-15H
Discontinued
VOZZ-15
APT, ZZ, 33", 4kVA
VOZZ-15G
VOZ-15H
Discontinued
VOG-15H
Discontinued
VOZ-20
VOHD-200/G
VOZZ0-20
APT, ZZ, 33", 5kVA
VOZZ-20G
LPT, ZZ, 26", 2.5kVA
LPT, ZZ, 35", 3.3kVA
APT, ZZ, 40", 6kVA
LPT, ZZ, 48", 4kVA
APT, ZZ, 55", 7.5kVA

1Multiply primary amps by rating factor to get max amp rating at 30C.
2Rating factor can vary with ratio.
31 Bushing is for line to ground only. 2 Bushing for line to line.
4LPT = 1 Bush, APT = 2 Bush. kVA higher when divided.

19-6

BuyLog Catalog

www.geelectrical.com

Rev. 1/08

Prices and data subject


to change without notice

You might also like