Three-phase Metering
Selection Guide for Socket, Bottom Connected and Switchboard Type.
To Select the Optimum Metering System:
1. Determine the circuit type and voltage
2. Compute or estimate the served load in amperes and select metering equipment from
the chart below and order as "Sim. To" Except: Current and Voltage Ratio.
Application
Meter
Type
Pulse
Initiator
Energy EM
170
F52 Pointer
F86 Cyclometer
N/A
10
Energy SS
I-210
Solid State
N/A
20
Register
ANSI Forms
TR
SC
100
200
320
100
200
320
3S, 4S
1S, 2S
3S, 4S
1S, 2S
Electronic KV2C Meters (Wide Range 120-480V Single and Three PhaseAll Functions)
Application
Meter
Type
Register
Pulse
Initiator
All
kV
kV2C
Option
Meter Class
S-Base
(Socket-Type)
TR
SC
20
200, 320
20
150
Switchboard
Type TP
Optocom.
Com. Part
Com. Outputs/Options
Programming
Software
Software
kV
Yes
MeterMate
MV90
Circuit
Voltage
Amps
ANSI
C12-10 Form
No.of
Jaws
120/208Y
0-200
16S
277/480Y
0-200
16S
34WY
Self
120/280Y
0-200
16S
277/480Y
0-200
16S
Contained
3W Network
120/208 Network
240
0-200
0-200
12S
12S
5
51
33W
480
120/208Y
277/480Y
0-200
0-10
0-10
12S
36S
36S
51
13
13
34WY
120/208Y
Transformer
277/480Y
0-10
0-10
9S
9S
13
13
Rated
3W Network
120/208 Network
240
0-10
0-10
45S
45S
8
8
33W
480
0-10
45S
Interval
(Min.)
Meter Programmed
with Demand Product No.
15
784X400030
784X401016
30
784X400031
784X401017
15
784X400030
784X401016
30
784X400031
784X401017
15
784X400030
784X401016
30
784X400031
784X401017
15
784X400030
784X401016
30
784X400031
784X401017
15
784X100014
784X101011
30
784X100015
784X101012
15
784X100014
784X101011
30
784X100015
784X101012
15
784X100014
784X101011
30
784X100015
784X101012
15
784X6000154
784X6010114
30
784X6000164
784X6010124
15
784X6000154
784X6010114
30
784X6000164
784X6010124
15
784X9000284
784X9010154
30
784X9000294
784X9010164
15
784X9000284
784X9010154
30
784X9000294
784X9010164
15
784X5000174
784X5010104
30
784X5000184
784X5010114
15
784X5000174
784X5010104
30
784X5000184
784X5010114
15
784X5000174
784X5010104
30
784X5000184
784X5010114
1If line 2 is grounded, a socket having the line 2 connector attached directly to the socket case may be used.
If line 2 is not grounded, a socket with the line 2 connector insulated from the case must be used to avoid inadvertent grounding of line 2.
2kV meter is wide ranging for voltage and automatically adjusts for circuit voltage listed.
3Pulse output for kV meter self contained is 10 Wh per pulse. Pulse output for kV meter transformer is 1 Wh per pulse.
4For switchboard order "Sim. To" except: Switchboard Type.
19-2
BuyLog Catalog
www.geelectrical.com
Rev. 1/08
Section 19
Product Number
120:120
240:120
288:120
480:120
760X034001
760X034002
760X034004
760X034006
55C Ambient
Window
Size
Product Number
With Low Base
3.0
4.0
3.0
2.0
2.0
2.9
2.9
2.4
1.8
1.5
2.500
3.062
3.062
3.062
3.062
750X033311
750X033313
750X033314
750X033315
750X033316
200:5
400:5
500:5
600:5
800:S
Type
Product
Service
Min.
Max.
JCT-0
JCM-0
JKM-0
JAM-0
JCL-0
750X023
750X025
750X041
750X021
750X028
200
200
10
100
1200
800
400
1200
400
4000
Window
Diameter Rating
inches
Factor
Bar
Bar
Bar
Bar
-
2.0
2.0
1.5
1.2
1500-5 Rating1
Acc'y. @
Meter
Relay
Burden2 Burden2 Lbs.
.3 B0.2
.3 B0.5
.3 B0.5
.3 B0.2
T50
6
6
15
15
25
Window
Diameter Rating
inches Factor
Acc'y @
Meter
Burden2
Relay
Burden2
Option/
Other
ITI
CBT
CBH
1.5
.3B2
Sch.
TCB
TAB
R6BA
R6B
250/251
252
For 2W Meter
Bar
Durh.
C130
Type
Product
Service
Min.
Max.
JCR-0
JCW-0
JAK-0
JAL-0
JCP-0
JAF-0
JCS-0
750X034
750X032
750X033
750X035
750X015
750X0103
750X0100
100
200
200
200
600
100
50
400
400
800
400
4000
3000
4000
Window
Diameter Rating
inches
Factor
1500-5 Rating1
Acc'y. @
Meter
Relay
Burden2 Burden2 Lbs.
2.00
2.00
3.00
2.38
2.0
2.0
4.0
2.0
.3 B0.2
.3 B0.5
.3 B0.5
.3 B0.5
4.50
4.88
1.3
2.0
.3 B0.1
.3 B0.1
C50
C50
3
4
9
7
28
26
28
Window
Diameter Rating
inches Factor
5.37
5.37
5.37
2.0
1.3
1.5
Acc'y @
Meter
Burden2
.3 B2
.3 B2
.3 B2
Relay
Burden2
Option/
Other
C200
C100
C200
Dual Ratios
Burial Type
Dual Ratios
Dual Ratios
Dual Ratios
Relay
Burden2
Option/
Other
ITI
CSE
CSH
CMF
Durh.
Sch.
TCW
TFW
AB
R6SA
R6S
R6M
RLC
Type
Product
Service
JCH-0
750X012
JCH-0C 750X112
JAH-0 750X0140
JAS-0
750X0141
JCB-0
750X011
JCB-0C 750X111
JAG-0
750X010
JAG-0C 750X110
JAG-0C3 750X110
JAD-0
750X020
JCD-0
750X031
JAB-0
750X036
Ratio Range
Min.
Max.
100
50
400
150
400
50
100
50
50
200
1500
200
800
2000
4000
2000
6000
6000
3000
5000
4000
4000
8000
3000
Window
Diameter Rating
inches
Factor
1500-5 Rating1
Acc'y. @
Meter
Relay
Burden2 Burden2 Lbs.
2.50
1.5/2.5
4.00
4.00
8.12
7.36
6.50
6.50
6.50
5.75
1.3
1.3
1.3
1.3
1.5
1.3
4.0
3.0
3.0
4.0
.6 B0.2
.3 B0.5
.6 B0.2
.6 B0.2
.6 B0.1
.3 B0.9
.3 B0.2
.3 B0.2
.3 B0.5
.3 B0.2
3.5/4.5
4.0
.3 B0.2
C35
C10
C100
C55
C55
C100
4
3
9
8
20
48
25
21
38
13
20
7
Window
Diameter Rating
inches Factor
2.50
5.75
4.00
8.12
7.36
6.50
6.50
6.50
5.75
8.12
3.5/4.5
1.3
1.3
1.3
1.5
1.3
2.0
2.0
1.5
3.0
3.0
2.0
Acc'y @
Meter
Burden2
.3 B1.8
.3 B1
.3 B2
.3 B1
.3 B1.8
.3 B2
.3 B1.8
.3 B1.8
.3 B1
.3 B1
.3 B1
Mul Ratio
High Relay Types
Mul Ratio
Mul Ratio
Mul Ratio
Dual Ratios
Dual Ratios
Opt "Grabbers"
ITI
Durh.
180
120/130/100
110/115
149
143
780/781
780/781
785/786
120/130
AD
149
ACL
AP
Sch.
R6L
R6P
1Multiply primary amps by rating factor to get max. amp rating at 30C.
2Performance and characteristics can vary with ratio/features.
3High Relay-Double Wide
Rev. 1/08
www.geelectrical.com
BuyLog Catalog
19-3
Section 19
Type
Product
Service
Min.
Max.
JAR-0
750X001
0.1
15
Window
Diameter Rating
inches
Factor
Wound
1500-5 Rating1
Acc'y. @
Meter
Relay
Burden2 Burden2 Lbs.
1.5
.3 B0.2
Window
Diameter Rating
inches Factor
Acc'y @
Meter
Burden2
Relay
Burden2
Option/
Other
12
ITI
AUX/CT
188
Durh.
Sch.
Type
Product
Service
Min.
Max.
JAI-0
JAU-0
750X093
750X091
50
50
800
800
Window
Diameter Rating
inches
Factor
1.75
1.75
1500-5 Rating1
Acc'y. @
Meter
Relay
Burden2 Burden2 Lbs.
1.5
1.5
2.5VA
2.5VA
Window
Diameter Rating
inches Factor
Acc'y @
Meter
Burden2
Relay
Burden2
0.5
0.5
Option/
Other
Term. Screws
With Leads
ITI
Durh.
Sch.
__ __ RT
__ __ RL
Voltage Transformers
Type
Product
Service
JEP-0C
JVA-0
JVP-1
YT-1557
760X135
760X034
761X030
760X099
Burden
Thermal
Lbs.
Fuse Option
ABB
ITI
Durh.
Sch.
0.3
0.3
0.3
W
M
Y
300VA
500VA
750VA
300VA
12
16
30
50
No
Yes
Yes
No
PPW
PPM
PPM
PPI
460/470
456
456
450
DF
DB
DB
DA
T5R
T6R
T6R
T7R
1Multiply primary amps by rating factor to get max. amp rating at 30C.
2Performance and characteristics can vary with ratio/features.
19-4
BuyLog Catalog
www.geelectrical.com
Rev. 1/08
Section 19
Type
JKM-2
JCM-2
JKC-3
JKM-3
JKS-3
JCM-3
JCB-3
JCM-4
JKM-4
JCB-4
JKS-5
JKM-5
JCM-5
JCB-5
Design
Wound
Wound
Wound
Wound
Wound
Bar
5.5' Win.
Bar
Wound
5.5' Win.
Wound
Wound
Bar
5.5' Win.
Volts
2500
2500
5000
5000
5000
5000
5000
8700
8700
8700
15000
15000
15000
15000
BIL
45
45
60
60
60
60
60
75
75
75
95
110
110
110
0.3 Accy
at Meter
Burden
B-0.5
B-2
B0.5
B-2
B0.1/2
B-2
B-2
B-2
B-2
B-2
B0.1/2
B-2
B-2
B-2
Max.
1200
4000
1200
800
800
4000
4000
4000
800
4000
800
800
4000
4000
Major2
30C Rating
Factor
1.5
1.3
1.5
1.5
1.5
1.3
1.3
1.3
1.5
1.3
1.5
1.5
1.3
1.3
Avg
Lbs.
15
35
15
29
30
62
85
62
29
85
50
47
95
110
Creep
(Inches)
11
Tap Sec.
Tap, Dual Sec.
Tap, Dual Sec.
Tap Sec.
Tap Sec.
Max.
800
4000
4000
4000
800
4000
1200
4000
800
4000
800
3000
800
3000
3000
3000
Major2
30C Rating
Factor
1.5
1.3
1.3
1.3
1.5
1.3
1.5
1.3
1.5/3
1.3
1.5/3
1.5/2
3
2
2
2
Avg
Lbs.
38
110
95
95
38
110
60
135
35
115
77
320
70
345
540
590
Creep
(Inches)
Other/
Options
Primary
Min.
10
600
10
5
15
1200
1200
1200
10
1200
15
5
1200
1200
Other/
Options
ABB
Type
8
9
KIN-60
KIR-60
CTWH-3-60-T50
CTWH-3-60-T100
KIR-75
CTWH-4-75-T100
KIR-11
CTWS-5-110-T20
CTWH-5-110-T200
Type
JKW-3
JCD-3
JCW-3
JCW-4
JKW-4
JCD-4
JKW-5
JCD-5
JCK-5
JCW-5
JKW-6
JKW-150
JKW-7
JKW-200
JKW-250
JKW-350
Design
Wound
5.5' Win.
Bar
Bar
Wound
5.5' Win.
Wound
5.5' Win.
Wound
Bar
Wound
Super-Bute
Wound
Super-Bute
Super-Bute
Super-Bute
Volts
5000
5000
5000
8700
8700
8700
15000
15000
15000
15000
25000
25000
34500
34500
46000
69000
BIL
60
60
60
75
75
75
110
110
110
110
150
150
200
200
250
350
0.3 Accy
at Meter
Burden
B-2
B-2
B-2
B-2
B-2
B-2
B-2
B-2
B0.5
B-2
B-2
B-2
B0.5
B-2
B-2
B-2
Primary
Min.
5
1200
1200
1200
10
1200
5
1200
5
1200
5
25
10
25
25
25
Tap, Sec.
Tap, Sec.
Tap, Sec.
19
13.5
Tap, Sec.
Tap, Sec.
Tap, Sec.
15
24
25
26
35
48
64
Tap, Sec.
Tap, Sec.
Tap, Dual Sec.
Tap, Sec.
Tap, Dual Sec.
Tap, Dual Sec.
Tap, Dual Sec.
1Multiply primary amps by rating factor to get max amp rating at 30C.
2Rating factor can vary with ratio.
Rev. 1/08
www.geelectrical.com
BuyLog Catalog
19-5
Section 19
Type
JVM-2
JVM-3
JVM-4
JVM-5
JVM-6
Design
Volts
2400
4800
7200
14400
24000
0.3 Accy
at Meter
BIL
Burden
45
Y
60
Y
75
Z
95/110
Z
125
Y
Major2
30C Rating
Max.
Factor
2400
4800
7200
14400
24000
Primary
Min.
2400
4200
7200
12000
Avg
Lbs.
30
30
85
85
100
Creep
(Inches)
Other/
Options
Fuse Option
Fuse Option
Fuse Option
Fuse Option
Creep
(Inches)
24000
Avg
Lbs.
44
105
105
105
74
95
105
24000
140
24000
14000
34500
20125
225
230
140
140
34500
20125
27600
46000
40250
69000
235
240
420
520
430
560
Other/
Options3
2 Bushing
2 Bushing
1-2 Bushing
1-2 Bushing
1 Bushing
1 Bushing
1-2 Bushing
2 Bushing
2 Bushing
1 Bushing
2 Bushing
2 Bushing
1 Bushing
2 Bushing
1 Bushing
2 Bushing
1-2 Bushing
2 Bushing
1 Bushing
1 Bushing
2 Bushing
1 Bushing
2 Bushing
Type
JVW-3
JVW-4
JVW-5
JVW-110
ABB ref
JVW-6
JVW-6
ABB ref
JVW-150
ABB ref
ABB ref
JVT-150
JVS-150
JVW-7
JVW-7
ABB ref
ABB ref
JVT-200
JVS-200
JVS-250
JVT-250
JVS-350
JVT-350
Design
Super-Bute
Super-Bute
Super-Bute
Super-Bute
Super-Bute
Super-Bute
Super-Bute
Super-Bute
Volts
4800
7200
14400
14400
14400
14400
24000
24000
24000
24000
34500
24000
14400
34500
20125
34500
36000
34500
20125
27600
46000
40250
69000
BIL
60
75
110
110
110
125
125
150
150
150
150
150
150
150
200
200
200
200
200
250
250
350
350
0.3 Accy
at Meter
Burden
Y
Z
Z
Y
Z
Y
Y
Z
Y
ZZ
Z
ZZ
ZZ
Y
Y
Z
Y
ZZ
ZZ
ZZ
ZZ
ZZ
ZZ
Major2
30C Rating
Max.
Factor
4800
7200
14400
14400
8400
Primary
Min.
2400
2400
7200
7200
7200
12000
12000
12000
23000
27600
19.6
19.6
19.6
21
21
27.2
26
27.5
26.1
27
27
26
27
27.2
37.5
36
36
50
52
64
66
1Multiply primary amps by rating factor to get max amp rating at 30C.
2Rating factor can vary with ratio.
31 Bushing is for line to ground only. 2 Bushing for line to line.
4LPT = 1 Bush, APT = 2 Bush. kVA higher when divided.