0% found this document useful (0 votes)
1K views1 page

S.C.S.S.V. Leakage Rate

This document contains a formula for calculating leakage rates of SCSSVs and plugs, along with tubing specifications. The API formula is provided to calculate leakage rate (Q) based on pressure increase (DP), test time (DT), and tubing volume (V) above the valve or plug. Tubing sizes from 2 3/8" to 4 1/2" are listed with weights, internal volumes, and example leakage rate calculations.

Uploaded by

francisryan4519
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views1 page

S.C.S.S.V. Leakage Rate

This document contains a formula for calculating leakage rates of SCSSVs and plugs, along with tubing specifications. The API formula is provided to calculate leakage rate (Q) based on pressure increase (DP), test time (DT), and tubing volume (V) above the valve or plug. Tubing sizes from 2 3/8" to 4 1/2" are listed with weights, internal volumes, and example leakage rate calculations.

Uploaded by

francisryan4519
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

Leakage Rate Calculation of SCSSV and Plugs

API Formula: Q=4(DP)V/DT


Tubing Tubing Cubic ft. per
Pressure Length of
SCF
SCF
Size Weight
Lineal ft.
Depth Volume Increase Test (Mins) Per Hour Per Min.
2 3/8" 4.7#
0.02171
486
10.55
160
30
225.09
3.75
5.95#
0.01901
0.00
#DIV/0! #DIV/0!
2 7/8"

6.5#
7.9#
8.7#

0.0325
0.02943
0.02783

3 1/2"

9.3#
12.95#
15.8#

0.04883
0.04125
0.03541

4 1/2" 12.75#
13.5#
15.5#
19.2#

0.08544
0.08381
0.07984
0.07227

500

16.25
0.00
0.00

100

30

216.67
#DIV/0!
#DIV/0!

3.61
#DIV/0!
#DIV/0!

0.00
0.00
0.00

#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!

0.00
0.00
0.00
0.00

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

MMS maximum allowable leak is 5 SCF per minute gas and 200 cc per minute liquid
Q=
DP=
DT=
V=

Leakage rate per hour


Pressure increase from start to end of test
Length of test in minutes
Volume of tubing above SCSSV or Plug