100% found this document useful (4 votes)
3K views6 pages

RC Two Way Slab Design (ACI318-05)

This document provides design calculations for the reinforcement of a two-way concrete slab. It includes dimensions of the slab panel, material properties, load calculations, moment calculations in two directions, and verification of minimum slab thickness. It also includes calculations of required flexural strength and reinforcement amounts in column and middle strips in both directions. Reinforcement amounts are checked against code requirements.

Uploaded by

emorider
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (4 votes)
3K views6 pages

RC Two Way Slab Design (ACI318-05)

This document provides design calculations for the reinforcement of a two-way concrete slab. It includes dimensions of the slab panel, material properties, load calculations, moment calculations in two directions, and verification of minimum slab thickness. It also includes calculations of required flexural strength and reinforcement amounts in column and middle strips in both directions. Reinforcement amounts are checked against code requirements.

Uploaded by

emorider
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Project

Job Ref.

QF DAR GROUP
Section Sheet no./rev.

QF 1

Calc. by

Date

Chk'd by

Date

App'd by

Date

MS

09-Nov-106

AE

IC

RC TWO WAY SLAB DESIGN TO ACI 318 05

y lx x

Column strip

ly

Middle strip

Column strip

Column strip

Middle strip

Column strip

TWO-WAY SLAB PANEL

200 mm Section at middle strip along X axis

Slab definition Slab thickness; Span along x dir; Span along y dir; Clear cover to positive reinforcement; Clear cover to negative reinforcement; Effective flanged beam section Flange width; Beam depth; Beam width; Materials Specified compressive strength of concrete; Specified yield strength of reinforcement; Modulus of elasticity; Loads Total factored ultimate load on slab; wu = 18.00 kN/m
2

h = 150 mm lx = 6000 mm ly = 4000 mm

Long span to short span ratio less than 2, hence two-way slab
cc = 20 mm cc = 20 mm bf = 1000 mm hb = 550 mm bw = 300 mm fc = 35 MPa fy = 415 MPa ESACI = 199948MPa

Project

Job Ref.

QF DAR GROUP
Section Sheet no./rev.

QF 2

Calc. by

Date

Chk'd by

Date

App'd by

Date

MS Check for the depth of slab provided Clear span x dir; Clear span y dir; Ratio; Moment of inertia of beam; Moment of inertia of slab along x axis; Moment of inertia of slab along y axis; Flexural stiffness ratio along x axis; Flexural stiffness ratio along y axis; Average flexural stiffness ratio; Minimum depth required;

09-Nov-106

AE

IC

lnx = lx - bw / 2 - bw / 2 = 5700 mm lny = ly - bw / 2 - bw / 2 = 3700 mm = max(lnx, lny) / min(lnx, lny) = 1.541 Ib = 6922916667 mm4 Isx = 1125000000 mm4 Isy = 1687500000 mm4 fx = Ib / Isx = 6.154 fy = Ib / Isy = 4.102 fm = (fx 2 + fy 2) / 4 = 5.128 hmin = 125 mm

PASS - slab thickness provided is sufficient for deflection


Moment computation (x direction) Width of column strip (half); Width of middle strip; Factored moment; Moment distribution for interior panel; Moment distribution in column and middle strips ly / lx = 0.67 fx ly / lx = 4.10 Moment distribution factors; Total column strip design moments; Column strip beam moments; Column strip slab moments; Total middle strip design moments; fx_neg = 0.85 fx_pos = 0.85 Mx_col_stp = fx_neg Mux = 161.56 kNm Mx_col_stp = fx_pos Mux = 86.99 kNm Mx_beam = 137.32 kNm Mx_beam = 73.94 kNm Mx_slab = Mx_col_stp - Mx_beam = 24.23 kNm Mx_slab = Mx_col_stp - Mx_beam = 13.05 kNm Mx_mid_stp = (1 - fx_neg) Mux = 28.51 kNm Mx_mid_stp = (1 - fx_pos) Mux = 15.35 kNm Required flexural nominal strength in column strip per 1 m width of slab Mnx_col = Mx_slab / (0.9 (2 lcol_stp - bf)) = 26.93 kNm/m Mnx_col = Mx_slab / (0.9 (2 lcol_stp - bf)) = 14.50 kNm/m Required flexural nominal strength in middle strip per 1 m width of slab Mnx_mid = Mx_mid_stp / (0.9 lmid_stp_x) = 15.84 kNm/m Mnx_mid = Mx_mid_stp / (0.9 lmid_stp_x) = 8.53 kNm/m Moment computation (y direction) Width of column strip (half); Width of middle strip; Factored moment; Moment distribution for interior panel; Moment distribution in column and middle strips lx / ly = 1.50 fy lx / ly = 6.15 Moment distribution factors; fy_neg = 0.60 lcol_stp = min(0.25 lx, 0.25 ly) = 1000 mm lmid_stp_y = lx - 2 lcol_stp = 4000 mm Moy = wu lx lny2 / 8 = 184.82 kNm Muy = 0.65 Moy = 120.13 kNm Muy = 0.35 Moy = 64.69 kNm lcol_stp = min(0.25 lx, 0.25 ly) = 1000 mm lmid_stp_x = ly - 2 lcol_stp = 2000 mm Mox = wu ly lnx2 / 8 = 292.41 kNm Mux = 0.65 Mox = 190.07 kNm Mux = 0.35 Mox = 102.34 kNm

Project

Job Ref.

QF DAR GROUP
Section Sheet no./rev.

QF 3

Calc. by

Date

Chk'd by

Date

App'd by

Date

MS

09-Nov-106 fy_pos = 0.60

AE

IC

Total column strip design moments; Column strip beam moments; Column strip slab moments; Total middle strip design moments;

My_col_stp = fy_neg Muy = 72.08 kNm My_col_stp = fy_pos Muy = 38.81 kNm My_beam = 61.27 kNm My_beam = 32.99 kNm My_slab = My_col_stp - My_beam = 10.81 kNm My_slab = My_col_stp - My_beam = 5.82 kNm My_mid_stp = (1 - fy_neg) Muy = 48.05 kNm My_mid_stp = (1 - fy_pos) Muy = 25.87 kNm

Required flexural nominal strength in column strip per 1 m width of slab Mny_col = My_slab / (0.9 (2 lcol_stp - bf)) = 12.01 kNm/m Mny_col = My_slab / (0.9 (2 lcol_stp - bf)) = 6.47 kNm/m Required flexural nominal strength in middle strip per 1 m width of slab Mny_mid = My_mid_stp / (0.9 lmid_stp_y) = 13.35 kNm/m Mny_mid = My_mid_stp / (0.9 lmid_stp_y) = 7.19 kNm/m Reinforcement calculations Stress block depth factor; Reinforcement percentage at strain of 0.004; Maximum reinforcement percentage; Column strip (x direction) Negative Reinforcement Depth to negative steel; Flexural resistance factor; Reinforcement required; Area of tension steel required; Minimum area of tension steel required; Maximum area of tension steel; Maximum allowable spacing; Area of tension steel provided; Actual tensile bar spacing provided; Positive reinforcement Depth to positive steel; Flexural resistance factor; Reinforcement required; Area of tension steel required; Minimum area of tension steel required; Maximum area of tension steel; Area of tension steel provided; dx_col = h - cc - Dcol_x / 2 = 124 mm Rux_col = Mnx_col / dx_col2 = 0.95 MPa reqx_col =0.85fc/fy[1-(abs(1-2Rux_col/(0.85fc)))] = 0.00233 dx_col = h - cc - Dcol_x / 2 = 124 mm Rux_col = Mnx_col / dx_col2 = 1.77 MPa reqx_col =0.85fc/fy[1-(abs(1-2Rux_col /(0.85fc)))] = 0.00439 1 = max(0.65, 0.85 - 0.05 (f'c - 28 MPa) / 7 MPa = 0.85 b = 0.85 1 fc / fy (0.003 / (0.003 + 0.004)) = 0.026 max = b = 0.026

Outer compression steel not required


2 Asx_req_col = reqx_col dx_col = 542 mm /m

Asx_min_col = max(1.4 MPadx_col/fy,(fc/1 MPa)dx_col1 MPa/(fy 4)) Asx_min_col = 440 mm2/m Asx_max_col = max dx_col = 3225 mm2/m smax = min(2 h, 450 mm) = 300 mm

Reinforcement provided (negative), No. 4 @ 200 mm centers


Asx_col = 664 mm2/m

PASS - area of steel provided is OK


sx_col = 200 mm

PASS - spacing of bars less than allowable

Outer compression steel not required


2 Asx_req_col = reqx_col dx_col = 288 mm /m

Asx_min_col = max(1.4 MPadx_col/fy,(fc/1 MPa)dx_col1 MPa/(fy 4)) Asx_min_col = 440 mm2/m Asx_max_col = max dx_col = 3225 mm2/m

Reinforcement provided (positive), No. 4 @ 200 mm centers


Asx_col = 664 mm2/m

PASS - area of steel provided is OK

Project

Job Ref.

QF DAR GROUP
Section Sheet no./rev.

QF 4

Calc. by

Date

Chk'd by

Date

App'd by

Date

MS Actual tensile bar spacing provided;

09-Nov-106 sx_col = 200 mm

AE

IC

PASS - spacing of bars less than allowable


Middle strip (x direction) Negative Reinforcement: Depth to negative steel; Flexural resistance factor; Reinforcement required; Area of tension steel required; Minimum area of tension steel required; Maximum area of tension steel; Maximum allowable spacing; Area of tension steel provided; Actual tensile bar spacing provided; Positive reinforcement Depth to positive steel; Flexural resistance factor; Reinforcement required; Area of tension steel required; Minimum area of tension steel required; Maximum area of tension steel; Area of tension steel provided; Actual tensile bar spacing provided; dx_mid = h - cc - Dmid_x / 2 = 124 mm Rux_mid = Mnx_mid / (dx_mid2) = 0.56 MPa reqx_mid = 0.85 fc/fy[1-(abs(1-2Rux_mid/(0.85fc)))] = 0.00136 dx_mid = h - cc - Dmid_x / 2 = 124 mm Rux_mid = Mnx_mid / dx_mid2 = 1.04 MPa reqx_mid = 0.85fc/fy[1-(abs(1-2Rux_mid/(0.85fc)))] =0.00255

Outer compression steel not required


2 Asx_req_mid = reqx_mid dx_mid = 315 mm /m

Asx_min_mid = max(1.4MPa dx_mid /fy,(fc/1 MPa) dx_mid1MPa/(fy 4)) Asx_min_mid = 440 mm2/m Asx_max_mid = max dx_mid = 3225 mm2/m smax = min(2 h, 450 mm) = 300 mm

Reinforcement provided (negative), No. 4 @ 200 mm centers


Asx_mid = 664 mm2/m

PASS - area of steel provided is OK


sx_mid = 200 mm

PASS - spacing of bars less than allowable

Outer compression steel not required


Asx_req_mid = reqx_mid dx_mid = 168.00 mm2/m Asx_min_mid = max(1.4 MPa dx_mid /fy,(fc/1 MPa) dx_mid1MPa/(fy 4)) Asx_min_mid = 440 mm2/m Asx_max_mid = max dx_mid = 3225 mm2/m

Reinforcement provided (positive), No. 4 @ 200 mm centers


Asx_mid= 664 mm2/m

PASS - area of steel provided is OK


sx_mid = 200 mm

PASS - spacing of bars less than allowable


Column strip (y direction) Negative Reinforcement: Depth to negative steel; Flexural resistance factor; Reinforcement required; Area of tension steel required; Minimum area of tension steel required; Maximum area of tension steel; Maximum allowable spacing; Area of tension steel provided; Actual tensile bar spacing provided; dy_col = h - cc - Dcol_x - Dcol_y / 2 = 111 mm Ruy_col = Mny_col / dy_col2 = 0.98 MPa reqy_col =0.85fc/fy [1 -(abs(1-2Ruy_col/(0.85fc)))] = 0.00241

Outer compression steel not required


2 Asy_req_col = reqy_col dy_col = 266 mm /m

Asy_min_col = max(1.4 MPady_col/fy,(fc/1 MPa)dy_col1 MPa/(4fy)) Asy_min_col = 394 mm2/m Asy_max_col = max dy_col = 2886 mm2/m smax = min(2 h, 450 mm) = 300 mm

Reinforcement provided (negative), No. 4 @ 200 mm centers


Asy_col = 664 mm2/m

PASS - area of steel provided is OK


sy_col = 200 mm

Project

Job Ref.

QF DAR GROUP
Section Sheet no./rev.

QF 5

Calc. by

Date

Chk'd by

Date

App'd by

Date

MS

09-Nov-106

AE

IC

PASS - spacing of bars less than allowable


Positive reinforcement Depth to positive steel; Flexural resistance factor; Reinforcement required; Area of tension steel required; Minimum area of tension steel required; Maximum area of tension steel; Area of tension steel provided; Actual tensile bar spacing provided; dy_col = h - cc - Dcol_x - Dcol_y / 2 = 111 mm Ruy_col = Mnx_col / dy_col2 = 1.19 MPa reqy_col =0.85fc/fy[1-(abs(1-2Ruy_col/(0.85 fc)))] = 0.00292

Outer compression steel not required


2 Asy_req_col = reqy_col dy_col = 322.74 mm /m

Asy_min_col = max(1.4 MPady_col/fy,(fc/1 MPa)dy_col1 MPa/(4fy)) Asy_min_col = 394 mm2/m Asy_max_col = max dy_col = 2886 mm2/m

Reinforcement provided (positive), No. 4 @ 200 mm centers


Asy_col= 664 mm2/m

PASS - area of steel provided is OK


sy_col = 200 mm

PASS - spacing of bars less than allowable


Middle strip (y direction) Negative Reinforcement: Depth to negative steel; Flexural resistance factor; Reinforcement required; Area of tension steel required; Minimum area of tension steel required; Maximum area of tension steel; Maximum allowable spacing; Area of tension steel provided; Actual tensile bar spacing provided; Positive reinforcement Depth to positive steel; Flexural resistance factor; Reinforcement required; Area of tension steel required; Minimum area of tension steel required; Maximum area of tension steel; Area of tension steel provided; Actual tensile bar spacing provided; dy_mid = h - cc - Dmid_x - Dmid_y / 2 = 111 mm
2 Ruy_mid = Mny_mid / dy_mid = 0.59 MPa

dy_mid = h - cc - Dmid_x - Dmid_y / 2 = 111 mm Ruy_mid = Mny_mid / dy_mid2 = 1.09 MPa reqy_mid = 0.85fc/fy[1-(abs(1-2Ruy_mid/(0.85fc)))] =0.00268

Outer compression steel not required


2 Asy_req_mid = reqy_mid dy_mid = 297 mm /m

Asy_min_mid = max(1.4 MPa dy_mid/fy,(fc/1 MPa) dy_mid1 MPa/(4fy)) Asy_min_mid = 394 mm2/m Asy_max_mid = max dy_mid = 2886 mm2/m smax = min(2 h, 450 mm) = 300 mm

Reinforcement provided (negative), No. 4 @ 200 mm centers


Asy_mid = 664 mm2/m

PASS - area of steel provided is OK


sy_mid = 200 mm

PASS - spacing of bars less than allowable

reqy_mid = 0.85 fc/fy[1-(abs(1-2Ruy_mid/(0.85fc)))] =0.00143

Outer compression steel not required


2 Asy_req_mid = reqy_mid dy_mid = 158 mm /m

Asy_min_mid = max(1.4 MPa dy_mid/fy,(fc/1 MPa) dy_mid1 MPa/(4fy)) Asy_min_mid = 394 mm2/m Asy_max_mid = max dy_mid = 2886 mm2/m

Reinforcement provided, No. (positive) 4 @ 200 mm centers


2 Asy_mid= 664 mm /m

PASS - area of steel provided is OK


sy_mid = 200 mm

PASS - spacing of bars less than allowable


Distribution reinforcement (for shrinkage and temperature) Minimum ratio of distribution reinforcement; t = 0.0018

Project

Job Ref.

QF DAR GROUP
Section Sheet no./rev.

QF 6

Calc. by

Date

Chk'd by

Date

App'd by

Date

MS

09-Nov-106

AE

IC

Minimum area of distribution reinforcement required; At_req = t h = 270 mm2/m Maximum allowable spacing of bars; Distribution reinforcement provided; Actual bar spacing provided; smax_t = min(5 h, 450 mm) = 450 mm

Distribution steel provided , No. 4 @ 400 mm centers


2 At_prov = 332 mm /m

PASS - area of inner steel provided (Distribution) OK


st = 400 mm

PASS - spacing of distribution bars is less than allowable


Check for shear Shear force on the slab (along long beam); Design shear strength of slab; Vu = wu (ly / 2 - bw / 2 - dx_mid) 1 m = 31.08 kN Vc = 0.75 (fc / 1 MPa) / 6 1 MPa 1 m dx_mid = 91.33 kN PASS - one-way shear capacity Check for clear cover (ACI 318 05 cl. 7.7.1) Permissible min nominal cover to all reinforcement; cmin = 20 mm Clear cover to tension reinforcement (negative); Clear cover to tension reinforcement (positive); cc_neg = 20 mm cc_pos = 20 mm

PASS - cover to steel resisting hogging exceeds allowable minimum cover PASS - cover to steel resisting sagging exceeds allowable minimum cover
Schematic reinforcement distribution.
y lx x

Asy_col Asx_col

Asx_col

Asx_mid Middle strip Column strip Column strip

ly

Asy_col

Asy_mid

Asx_mid

Asy_mid

Column strip

Middle strip

TWO-WAY SLAB PANEL