Omron
Omron
Introduction
The OMRON RX3 Plus measures your blood pressure and pulse simply and quickly from the wrist, without the use of an inflation bulb or stethoscope. The measurement values are stored in the memory of the OMRON RX3 Plus. The OMRON RX3 Plus fits wrist circumferences from 13.5 to 19.5 cm.
RX3 Plus
Instruction manual
page
Table of contents
1 How to obtain meaningful blood pressure readings 2 Overview 3 Preparation 3.1 Insert batteries 3.2 Fit wrist cuff 4 Operation 4.1 Control functions 4.2 Set date and time 4.3 Measurement 4.4 Read display 5 Memory 5.1 Recall average value 5.2 Recall previous values 5.3 Erase memory 6 Storage 7 Faults: causes and rectifications 8 Maintenance and spare parts 9 Technical data 10 General information about blood pressure 3 4 5 5 6 7 7 8 9 10 11 11 11 12 13 13 14 15 16
2 Overview
C D E F
B G
A B C D
3 Preparation
3.1 Insert batteries
2 Insert two batteries in the battery compartment. Caution! Use two identical 1.5V alkaline batteries type AAA!
SY
Sm mH g
DAT E/TI
SET
ME
SET
UST
ADJ
DI
PU mH LSE/m g in
Am
1 Bare your wrist. Caution! Push up your sleeve: avoid constricting the blood flow!
g
E/TI
SET
ME
SET
UST
SET IME SET ADJ UST
ADJ
3 Hold the end of the wrist cuff and wrap it around your wrist. Caution! Be sure the wrist cuff fits closely; do not pinch your arm!
Note: attach the monitor upside down for reliable measurement at your right wrist.
SY Sm mH
PU mH LSE/m g in
DAT
Am
E/T
DI
DI
DAT
PU AmmH LS E/m g in
SY Sm mH
4 Operation
4.1 Control functions
DATE/TIME SET
C D
L M
SYSmmHg
SET
ADJUST
E
DIAmmHg
PULSE/min
N P
R S T
C D E F
H Date. J Systolic blood pressure in mmHg. K Diastolic blood pressure in mmHg. L Memory display: 21 values in memory. M Average value of the latest 3 measurements displayed. N Monitor blood pressure: flash measurement takes place, light up - finish measurement. P Pulse: heartbeats per minute. Q Time. R Inflation: wrist cuff inflates and measurement starts. S Deflation: wrist cuff deflates and measurement finishes. T Battery exhausted: batteries are weak/exhausted.
DATE/TIME SET
DATE/TIME SET
DATE/TIME SET
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
2 Press set button for 2 seconds. Press adjust button to set the current year.
DATE/TIME SET
DATE/TIME SET
DATE/TIME SET
DATE/TIME SET
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
3 Press set button to proceed to month setting. Press adjust button to set the current month.
4 Press set button to proceed to day setting. Press adjust button to set the current day.
DATE/TIME SET
DATE/TIME SET
DATE/TIME SET
DATE/TIME SET
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
5 Press set button to proceed to hour setting. Press adjust button to set the current hour.
DATE/TIME SET
6 Press set button to proceed to minute setting and press adjust button to set the current minutes.
DATE/TIME SET
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
4.3 Measurement Caution! Allow an interval of at least three minutes between two successive measurements!
SYSmmHg
DATE/TIME SET
SET ADJUST
DIAmmHg
PULSE/min
1 Sit comfortably upright with your feet flat on the floor. Caution! The OMRON RX3 Plus should always be at heart height during measurement!
DATE/TIME SET
SYSmmHg
SET
ADJUST
DIAmmHg
PULSE/min
2 Press on/off button to start measurement. The OMRON RX3 Plus measures during inflation! Caution! Sit still, do not move, do not speak and do not touch the OMRON RX3 Plus! 4.4 Read display
DATE/TIME SET
DATE/TIME SET
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
1 Read the values of blood pressure and pulse from the display. Note: display shows alternately date, blood pressures and time, heartbeats.
DATE/TIME SET
SYSmmHg
SET
ADJUST
DIAmmHg
PULSE/min
2 Note date, time and values in your personal blood pressure pass.
5 Memory
5.1 Recall average value
DATE/TIME SET
DATE/TIME SET
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
L Memory display: 21 values in memory. M Average value of the latest 3 measurements displayed. 1 Press memory button. Note: display shows alternately blood pressures and heartbeats. 5.2 Recall previous values
DATE/TIME SET
DATE/TIME SET
SYSmmHg
SET
ADJUST
SYSmmHg
DATE/TIME SET
SET
ADJUST
SYSmmHg
SET
ADJUST
H
M
Q
M M
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
H/Q Date/time of measurement. 1 Press memory button for latest and previous values. Press on/off button to turn off power. Note: display shows alternately date, blood pressures and time, heartbeats.
11
DATE/TIME SET
SYSmmHg
DATE/TIME SET
SET
ADJUST
SYSmmHg
SET
ADJUST
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
2 Press memory button and simultaneously on/off button to erase memory. Caution! All stored values will be erased! Press on/off button to turn off power.
12
6 Storage
Store the OMRON RX3 Plus in the hard case in a dry, closed place with a temperature between -20C and 60C. Remove the batteries if you not intend to use the OMRON RX3 Plus for 3 months or more.
Correct reading Movement, sound Wait for at least not possible vibration, weak pulse three minutes to repeat measurement Low voltage Display empty Inexplicable values Wrong working method Batteries weak/exhausted Fit two new identical 1.5V alkaline batteries type AAA Follow instructions, repeat measurement
13
14
9 Technical data
Product name Model Display Measurement range Accuracy Inflation Deflation Pressure detection Measurement method Memory Power supply Battery life Operating temperature /humidity Operating environment Storage temperature / humidity Weight Outer dimensions Wrist circumference Accessories Note = Type B Manufacturer OMRON Digital Blood Pressure Monitor RX3 Plus Digital LCD Pressure: 0 - 299 mmHg / Pulse: 40 - 180 /minute Pressure: 3 mmHg / Pulse: 5% of display reading Automatic by electric pump Automatic rapid deflation system Electrostatic capacity pressure sensor (capacitive) Oscillometric method 21 Measurements 2 x 1.5V Alkaline batteries AAA New batteries will last for approx. 400 measurements +10C to +40C / 30% to max. 85% relative humidity Free from excessive vibrations, shocks, magnetic fields, electrical noise, etc. -20C to +60C / 10% to max. 95% relative humidity Approx. 160 g including batteries Approx. 79 mm (W) x 47 mm (H) x 71 mm (D) Approx. 13.5 cm to 19.5 cm Instruction manual, guarantee card, blood pressure pass, 2 alkaline batteries, storage box Subject to technical modification without prior notice 0197 OMRON HEALTHCARE Co., Ltd. 24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto, 615-0084 Japan OMRON HEALTHCARE EUROPE B.V. Kruisweg 577, NL-2132 NA Hoofddorp
EU-representative
This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive). This blood pressure monitor is designed according to the European standard EN1060, Non-invasive sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for electromechanical blood pressure measuring systems.
15
80
85
90
100 110
Health and blood pressure The incidence of hypertension increases with age. In addition, a lack of exercise, excess body fat and high levels of cholesterol (LDL), which sticks to the inside in blood vessels, reduces elasticity of these vessels.
16
mmHg
If your blood pressure reaches upper values of 140 - 160 mmHg and lower values of 90 - 95 mmHg in repeated measurements over several days, you should consult your doctor for detailed medical examination. You can assist the treatment prescribed by your doctor in the following ways: Loose weight and lower your cholesterol level by reducing the calories and fat in your diet. Cut down on animal fats and eat more fruit and vegetables. Reduce the consumption of alcohol. Reduce the intake of salt: the German League for Combating High Blood Pressure recommends six grams of salt per day (i.e. one teaspoon) on average. Stop smoking. Take regular exercise. Monitor your blood pressure.
18