Drilling Tools & Subs Inspection Report: Visual Body, Visual Connections, Blacklight Connections, Dimensional 3
Drilling Tools & Subs Inspection Report: Visual Body, Visual Connections, Blacklight Connections, Dimensional 3
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 27/07/2011
Report No.1903
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
E0367544 (70343)
BIT SUB
NC 35
4.3/4
4.17/32
21/32
3.13/16
6.7/8
3.1/4
N/A
N/A
ACC
ACC
4.4
BOX
3.1/2 REG 4.3/4 4.1/4 21/32 3.19/32 7.1/2 3.1/4 N/A N/A ACC
BOX
ACC
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
27/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 28/07/2011
Report No.1904
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
W/D 5085-009
CUP TESTER
NC 50
6.9/32
6.3/32
21/32
5.9/32
N/A
N/A
N/A 10.19/32
ACC
NC 50
6.9/32
1.1/2
6.3/32
N/A
N/A
4.13/32
N/A
7.1/2
ACC
ACC
2.31
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
28/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 28/07/2011
Report No.1905
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
GM 2326
CIRCULATING HEAD
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
2.7/8 EUE
3.5/8
2.7/16
N/A
N/A
N/A
N/A
N/A
N/A
ACC
ACC
3.45
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
28/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 28/07/2011
Report No.1906
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
KCA 231
CASING SCAPPER
3.1/2 REG
4.1/4
4.5/32
21/32
3.19/32
N/A
N/A
N/A
4.1/4
1.9/32
4.1/8
N/A
N/A
3.25/32
N/A
7.3/32
ACC
ACC
3.64
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
28/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 28/07/2011
Report No.1907
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
0363980
GRAY VAVLE
3.1/2 IF
4.25/32
4.19/32
21/32
4.3/32
N/A
N/A
N/A
N/A
ACC
NC 38
4.25/32
29/32
4.19/32
N/A
N/A
N/A
N/A
ACC
ACC
2.27
3.1/2 IF
4.25/32
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
28/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 28/07/2011
Report No.1908
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
E0367545
BIT SUB
NC 38
4.3/4
4.17/32
21/32
3.13/16
7.5/16
3.1/4
N/A
N/A
ACC
ACC
4.39
BOX
3.1/2 REG 4.3/4 4.9/32 11/16 3.19/32 7.1/2 2.3/4 N/A N/A ACC
BOX
ACC
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
28/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 28/07/2011
Report No.1909
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
L295
LIFT CAP
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4IF
8.1/4
2.13/16
N/A
N/A
N/A
N/A
N/A
N/A
ACC
ACC
1.1
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
28/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 28/07/2011
Report No.1910
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
L78
LIFT CAP
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4IF
7.15/16 2.13/16
N/A
N/A
N/A
N/A
N/A
N/A
ACC
ACC
1.1
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
28/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 28/07/2011
Report No.1911
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
L181
LIFT CAP
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4IF
7.15/16 2.13/16
N/A
N/A
N/A
N/A
N/A
N/A
ACC
ACC
1.1
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
28/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 28/07/2011
Report No.1912
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
L430
LIFT CAP
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4IF
8.1/4
2.13/16
N/A
N/A
N/A
N/A
N/A
N/A
ACC
ACC
1.1
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
28/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 29/07/2011
Report No.1913
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
KCA 233
LIFTING SUB
4.23/32
4.5/8
N/A
N/A
3.15/16
N/A
7.15/16
ACC
ACC
2.56
PIN X PIN
3.1/2 IF (NC 38) 4.23/32 2 4.5/8 N/A N/A 3.15/16 N/A 7.15/16 ACC ACC
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
29/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 29/07/2011
Report No.1914
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
KCA 23
LIFTING SUB
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4.23/32
4.5/8
N/A
N/A
3.15/16
N/A
7.15/16
ACC
ACC
2.56
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
29/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 29/07/2011
Report No.1915
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
EQ36930
CROSSOVER SUB
3.1/2 H90
4.25/32
4.23/32
21/32
4.3/16
N/A
N/A
N/A
N/A
ACC
2.3/16
4.11/16
N/A
N/A
3.29/32
N/A
N/A
ACC
ACC
2.07
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
29/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 29/07/2011
Report No.1916
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
248333.3
CROSSOVER SUB
3.1/2 REG
4.1/4
1.1/4
4.5/32
N/A
N/A
3.3/4
N/A
N/A
ACC
ACC
1.34
PIN X PIN
3.1/2 REG 4.1/4 1.1/4 4.5/32 N/A N/A 3.3/4 N/A N/A ACC ACC
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
29/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 29/07/2011
Report No.1917
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
Q248307Q
BIT
3.1/2 IF
4.23/32
4.21/32
21/32
4.1/16
N/A
N/A
N/A
N/A
ACC
BOX X BOX
ACC
ACC
1.80
SPT
3.1/2 IF
4.23/32
4.21/32
21/32
4.1/16
N/A
N/A
N/A
N/A
ACC
ACC
ACC
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
29/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 29/07/2011
Report No.1918
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
KCA 232
LIFTING SUB
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
ACC
4.23/32
4.5/8
N/A
N/A
3.15/16
N/A
7.15/16
ACC
ACC
2.56
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
29/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 29/07/2011
Report No.1919
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
Q534Q
CUP TESTER
4.25/32
21/32
4.1/16
3.1/2
N/A
N/A
ACC
1.1/32
4.9/32
N/A
N/A
4.21/32
N/A
5.29/32
ACC
ACC
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
29/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II
JCI
JC International Limited
RIG: T- 41
P.O.NO.
W.O.NO.
DATE: 29/07/2011
Report No.1920
INSPECTION PROGRAM:
SPECIFICATION:
DS-1 STANDARD.
CATEGORY
3-5
1
ALL DIMENSIONS IN INCHES ID. NO DESCRIPTION MPI on Critical Area Length (Ft.)
Width
Dia.
Conn. Length
Lead Guage
Tong Space
REMARK
Cond.
21519-12
JUNK BASKET
3.1/2 REG
5.1/2
4.3/32
21/32
3.17/32
N/A
N/A
N/A 18.13/16
1.1/32
4.9/32
N/A
N/A
4.21/32
N/A
10.1/8
ACC
ACC
2.85
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
1 1
COMMENTS:
CS = Corroded Seal
29/07/11
CUSTOMER SIGNATURE:.. DATE: INSPECTOR: SIMON OGBAN ASNT LEVEL II