ENGINEERING SPECIFICATIONS 50 and 60 SERIES Tannin (ppm) - SulfurStat Iron - ferrous - clear water Minimum pH Filtration - nominal rating (microns) #1 setting - salt lbs. / Grains removed #2 setting - salt lbs.

Uploaded by

api-114665243
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
627 views

Watermax Tech Specs

ENGINEERING SPECIFICATIONS 50 and 60 SERIES Tannin (ppm) - SulfurStat Iron - ferrous - clear water Minimum pH Filtration - nominal rating (microns) #1 setting - salt lbs. / Grains removed #2 setting - salt lbs.

Uploaded by

api-114665243
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ENGINEERING SPECIFICATIONS

50 & 60 SERIES
Tannin (ppm) Sulfur (ppm) - SulfurStat Iron (ppm) - ferrous - clear water Maximum Compensated Hardness Maximum Chlorine (ppm) Minimum pH Filtration - nominal rating (microns) #1 Setting - Salt lbs./Grains removed #2 Setting - Salt lbs./Grains removed #3 Setting - Salt lbs./Grains removed #4 Setting - Salt lbs./Grains removed Media Amount Compartment #1 Media Amount Compartment #2 Media Amount Compartment #3
Fine Mesh Cation Resin

53MAQ 63MAQ

53BEQ 63BEQ

53MXQ 63MXQ

53MDQ 63MDQ

52AMQ 62AMQ

52APQ 62APQ

52AKQ 62AKQ

52AJQ 62AJQ

*
0 0 0 90 0 7 20 1.1/5,900 3.2/16,300 6.2/26,700 9.5/32,500 1.5 lbs. Empty 1.06 cu.ft. 2.4 .5 20-120 0 0 0 90 3 7 25 1.1/5,900 3.2/16,300 6.2/26,700 0 0 12 110 0 7 20 1.6/8,400 4.2/20,000 9.6/38,700 0-2 0 0 90 0 7 20 NA NA 8.5/23,100 0 0 12 90 0 7 20 1/5,200 2.7/11,900 6.2/23,100

** ***
0 0-5** 2-12** 90 0 7 20 NA NA 6.2/23,100 9.3/29,800 NA 27 lbs. 1.06 cu.ft. Empty*** .5 30-120 19.6 11 10 psi NA NA 44/80 61/89 167 YES 0 0 15 90 0 7 20 NA NA 6.2/23,100 9.3/30,300 NA .4 cu.ft. 1.06 cu.ft. 7 .5 30-120 19.6 11 10 psi NA NA 44/80 61/89 160 YES

****
0 0 5 60 0 6.3 20 NA 2.7/11,900 6.2/23,100 9.3/30,300 NA .4 cu.ft. 1.06 cu.ft. 7 .5 30-120 20.5 12.5 11 psi NA 23/70 44/80 61/89 180 YES

9.5/32,500 14.4/49,300 10.7/30,300 9.3/30,000 2.0 lbs. .4 cu.ft. 1.06 cu.ft. 3 .5 20-120 19.5 13 11 psi 12/17 18/20.1 38/31.3 56/40.3 152 YES 1.5 lbs. .6 cu.ft. 1.06 cu.ft. 2.4 .5 20-120 17 11 12 psi 12/13.5 26/20.5 58/36.5 74/44.5 168 YES 1.5 lbs. .3 cu.ft. 1.06 cu.ft. 2.4 .5 20-120 17 11 12 psi NA NA 47/31 64/39.5 152 YES NA 6 lbs. 1.06 cu.ft. 5 .5 20-120 23 11 9 psi 12/24 18/27 38/37 58/56 140 YES

Backwash Rate (gpm) @ min. water pressure-Max. flow to drain

Brine Line Flow Control Refill (gpm) Water Pressure (min-max psi) Flow Rate @ 25 psi drop Flow Rate @ 15 psi drop
As tested by Hague As tested by Hague

19.5 11 11 psi 12/14.3 18/17.5 38/28.1 56/37.6 135 YES

Pressure Drop @ Service Flow Rate Of 8 gpm (#1 Salt setting) total length of reg. Min / gal (#2 Salt setting) total length of reg. Min / gal (#3 Salt setting) total length of reg. Min / gal (#4 Salt setting) total length of reg. Min / gal Shipping weight (lbs.) Bacteriostatic - KDF Process Media - Listed With The U.S. EPA As A Bacteriostatic (Not certified Device. U.S. EPA #54369-OH-001 by WQA)

Use clean white pellet or solar salt. Valve Inlet/Outlet 1 Drain Line (Minimum I.D.) 1/2 Water Temperature (Min-Max) 40-120 F Height (Inches) 38-1/4 Floor Space (Inches) 15 X 30 Salt storage capacity: 200 lbs, 90kg Brine & Rinse total: .65 gpm Brine Draw : .25 gpm Rinse: .4 gpm Electric rating: 115V, 60 cycle. Iron reduction to .3 ppm or less. (Not certified by WQA) When adding media in the field, check for proper settings (See specifications, above.)

**Must have a minimum of 2 ppm iron and a minimum of 200 ppm TDS. ***This model has no backwash flow control button or retainer. Must have a minimum of 7 gpm @ 30 psi available for proper backwash. ****Calcite will add additional hardness to water before softening.

Rate of flow must be verified at the end of 1/2 I.D. drain line. Any hardness over 10 gpg will increase the potential for Calcium Carbonate precipitation. As the hardness increases, so does the potential for this precipitation. Must use citric acid to regenerate along with salt. Models 63MAQ, 63BEQ, 63MXQ, 62AMQ, 62APQ, 53MAQ, 53BEQ, 53MXQ, 52AMQ and 52APQ are certified by WQA. All other models are not certified and tested by WQA.

Regeneration every 96 hours is required when iron is present in the raw water supply.

Use Salt Setting #3 or #4. *Municipally supplied chlorinated water only.