0% found this document useful (0 votes)
10 views

Skill 0

This document contains instructions for programming ladder logic diagrams for several automation systems. It describes the behaviors of lights and components based on the states of sensors and switches. The systems include: 1. A process with lights L1-L4 that turn on and off or blink based on the states of switches S1-S4. 2. A filling system where conveyor L1 and liquid valve L2 are controlled by manual switch S1, object sensor S2, level sensor S3, and count sensor S4. 3. A process where lights L1-L3 turn on for increasing durations each time lower limit switch S5 is triggered, and light L4 turns on if all loads are
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views

Skill 0

This document contains instructions for programming ladder logic diagrams for several automation systems. It describes the behaviors of lights and components based on the states of sensors and switches. The systems include: 1. A process with lights L1-L4 that turn on and off or blink based on the states of switches S1-S4. 2. A filling system where conveyor L1 and liquid valve L2 are controlled by manual switch S1, object sensor S2, level sensor S3, and count sensor S4. 3. A process where lights L1-L3 turn on for increasing durations each time lower limit switch S5 is triggered, and light L4 turns on if all loads are
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 3

Ph: 04362 227725, +91-99431 20025, [email protected].

SKILL-0
1. S1 ONL1 Blink after 20 blink of L2 ON S2 ONL1 ON & L2 blink S3 ONL3 ON after 15 sec & L3 off after 10 sec S4 ONL4 ON S4 OFFL4 ON 2. S1 ONTimer 1 reset for every 6 sec at time of 10 reset L1 ON, L2 OFF, 3. L1 ON if S1 ON, If the S1 is OFF L2 ON 4. In this system after counting 25 object L1 off, after 10min the system again come to On (L1) stage the after detecting 35 object L1 must come off.

5. Make a ladder for this function

6.

LOWER LIMIT SWITCH-S5 UPPER LIMIT SWITCH -S6 MANUAL SWITCH -S1 L1 IS FOR BOTH UPWARD & DOWNWARD MOVEMENTS. IF S5 ON FOR 1st time L1 ON FOR 10sec AT 2nd TIME L1 ON FOR 20sec AT 3.. TIME L1 ON FOR 30sec 7. Filling system, S1 on L1 on if S2 on L1 off, L2 on, if S3 on L2 off & L1 on If S4 get signal 15 time total process will be off.

L1conveyer L2liquid Control valve S1manual switch S2sensor to fine object S3level sensor S4sensor to count

8. Make a ladder for this function

7.S1(push button) on L1 on for 5 sec,L2 on for 8 sec, L3 on for 10 sec, if all load off L4 on