Resume Example
Resume Example
1. PERSONAL PARTICULARS
Page 1 of 9
3. PROFESSIONAL TRAINING AND COURSE ATTEND
22 May 2008:
Attent Positive Material Identification (PMI) course at ITC Skill Development Sdn
Bhd, Puchong Selangor, Malaysia. Conducted by ZL Tech, Jerman.
5 – 16 May 2008:
Attend Eddy Current Testing (ECT) course MLVK Level II conducted by Agency
Nuclear Malaysia, Bangi, Malaysia.
24 - 28 March 2008:
Attend Train The Trainer course at Perbadanan Sumber Manusia Berhad,
Damansara, Selangor, Malaysia conducted by SHEQ Consultancy Trainer. This
course objective is to train how to be a good trainer and managing the good trainer
preparation.
23 - 27 July 2007:
Attend Radiography Interpreter (RI) course MLVK Level II conducted by Agency
Nuclear Malaysia, Bangi, Malaysia.
18 – 19 March 2006:
Attend Authorized Entrant & Standby Person for Confined Space as per
05/12/AESP/2006/3 Course Code at ITC Skill Development Sdn Bhd, Puchong
conducted by NIOSH Trainer.
9 – 17 May 2005:
A.P.I 510 Pressure Vessel Inspections Certification Preparation Course accordance
to ASME II, ASME V, ASME VIII, and ASME IX at Concorde Hotel, Shah Alam,
Selangor, Malaysia, conducted by Authorised A.P.I Instructor from IRC, U.K.
June 2004:
NIOSH PETRONAS SAFETY PASSPORT COURSE at NIOSH East Coast Branch,
Kertih Terengganu, Malaysia.
Page 2 of 9
Jan 2004 to present :
In-house training for ASNT Level II course in Ultrasonic Testing, Magnetic Particle,
Dye Penetrant Testing, Radiography Testing, at Intestmal Corporation Training
Room, Puchong Selangor, Malaysia, conducted by qualified Level III and Senior
Inspector.
4. EXPERIENCE SUMMARY
Other inspection experience includes vendor surveillance, plant corrosion survey, RBI
inspections, smallbore inspection program, piping corrosion survey and etc which
along with being computer literate- report writing, report reviewing and data input.
Also, familiar with plant shutdown, preparation/planner plant turnaround and plant
maintenance. Involved in repair activity with approved procedure.
International Plant:
Bharat Petroleum Corporation Limited, Mumbai India.
5. WORKING EXPERIENCES
Page 3 of 9
Date : 22 April 2009 – 05 May 2009
Company : S.E.M INSPECTION SDN. BHD.
Seremban, Negeri Sembilan.
Position : Authorized Static Equipment Inspector (API 510)
Scope work : Seconded to Malaysia LNG Sdn. Bhd. as an Static Equipment
Inspector to perform visual inspection during Module 8
Shutdown 2009.
Scope of work :
• As a trainer for company to conduct several course/training organized by ITC.
• Prepared facilities such as computer, course note, multimedia, and souvenir and
also do reservation for room training if conducted outside, such as hotel and etc.
• Prepared a material for course/training notes organized by ITC
• Prepared a material for practical training and examination such as sample/test
piece (pipe, plate and etc).
• Prepared a material for assessment such as quiz, tutorial and examination that
comply with a standard or certificate organization.
• Managing the marketing of courses/training organized by ITC and creates a
related brochure.
• Attend course/training for upgrading personal competency.
• Revision a courses/training notes, slide presentation and assessment.
• To organise all type of courses to fulfil requirements of the oil, gas and
Petrochemical industries related to engineering inspection and maintenance
activities.
Page 4 of 9
1-5 September 2008
Organized the API RP 579 Fitness For Services course that was held at Concorde
Hotel Shah Alam, Selangor.
February 2009
Seconded to Petronas Fertilizer (Kedah) Sdn. Bhd. As Authorized Static Equipment
Inspector (API 510) during fabrication column repair. To perform visual inspection,
monitor welding and fabrication activity, witnessed Non-Destructive Testing and
making/reviewed report accordingly.
October 2008
Seconded to Petronas Fertilizer (Kedah) Sdn Bhd as Authorized Static Equipment
Inspector (API 510) during emergency shutdown.
June 2008
Seconded to Vinyl Chloride Malaysia Sdn Bhd as Authorized Static Equipment
Inspector (API 510) during VCMSB Reactor Shutdown 2008. To perform visual
inspection on external and internal reactor and monitor repair activity.
Page 5 of 9
April 2008
Seconded to Petronas Fertilizer (Kedah) Sdn Bhd as Authorized Static Equipment
Inspector (API 510) during April Emergency Shutdown 2008. To perform visual
inspection and witness leak test (pneumatic & hydrotest).
Scope of work :
• To performed NDT activities such as Ultrasonic Flaw Detection Testing,
Ultrasonic Thickness Measurement, Magnetic Particle Inspection, Red Dye
Penetrant Inspection, Videoscopic Inspection and Hardness Testing for various
assignment.
• Assigned as Welding Inspector to monitor all welding activities before, during and
after welding for several projects involved.
• To witness welder test (WQT), hydro testing, leak testing, post weld heat
treatment (PWHT) and material verification.
• To participate on preparation of final documentation, welding summary and filing
of close-up reports in accordance to client reporting and documentation system.
• To perform report presentation session to client representative upon completion of
works and brief on inspection finding and raise of technical recommendation.
• To perform visual inspection on pressure vessel, piping, boiler, furnace, heater,
reactor and etc as Authorized Inspector.
• To perform plant survey / corrosion survey including painting maintenance.
Project Involved:
January 2007
Seconded to Petronas Penapisan Melaka Sdn Bhd as Static Equipment Inspector
(API 510) during PSR-1 PPMSB Turnaround 2007.
June 2006
Seconded to Vinyl Chloride Malaysia Sdn Bhd as Static Equipment Inspector (API
510) during VCMSB Turnaround 2006.
Page 6 of 9
January 2006
Seconded to Petronas Penapisan (Melaka) Sdn Bhd as NDT Technician. To
performed Boroscope Inspection activities.
Dec 2005
Seconded to Petronas Penapisan (Melaka) Sdn Bhd as Static Equipment Inspector
cum Visual Inspector during Small Bore Project.
Nov 2005
Seconded to Syarikat Bersaudara Lutong as NDT Technician. To perform Vacuum
Box Testing at Miri Crude Oil Terminal (MCOT).
August 2005
Seconded to Petronas Penapisan (Melaka) Sdn Bhd as Static Equipment Inspector
cum Visual Inspector during Small Bore Project.
July 2005
Seconded to Petronas Fertilizer (Kedah) Sdn Bhd as Static Equipment Inspector
during PFKSB Turnaround 2005, Gurun, Kedah. To perform internal and external
inspection activities on static equipment and others related equipment.
Page 7 of 9
Jan – March 2005
Seconded to Petronas Penapisan (Melaka) Sdn Bhd as NDT Technician during
maintenance work at PPMSB Plant. To perform Magnetic Particle Inspection, Dye
Penetrant Inspection and UT Thickness Gauging.
Seconded to Nam Fatt Fabricate as NDT Technician during project CIQ Passenger
Hall Phase I. To perform Magnetic Particle Inspection and Hardness Test activities.
Seconded to Petronas Fertilizer Kedah Sdn Bhd as NDT Technician during PFK
July 2004 Shutdown. To perform Dye Penetrant Inspection activities at PFK Gurun
Plant.
Seconded to Nam Fatt Fabricate as NDT Technician during project CIQ Roof
Structure. To perform Magnetic Particle Inspection and Dye Penetrant Inspection
activities.
July 2004
Seconded to Perwaja Steel Sdn Bhd as Static Equipment Inspector during SMS
Annual Shutdown 2004. To perform internal and external visual
inspection activities on piping, static equipment and other related
equipment.
June 2004
Seconded to Mets One Sdn Bhd as NDT Technician during Boiler repair at Plantani
Food Supp. Sdn Bhd. To perform UT Thickness Measurement activities
and collecting thickness measurement data.
Seconded to TMM Engineering Sdn Bhd as NDT Technician during Serdang Lateral
Pipeline project. To perform Magnetic Particle Inspection activities at
Putrajaya.
May 2004
Seconded to TNB Jana Manjung as Static Equipment Inspection during Equipment
Inspection for RBI Project. To perform external and internal inspection activities on
static equipment and other related equipment as per client request.
Page 8 of 9
April 2004
Seconded to Petronas Penapisan Melaka Sdn Bhd as NDT Inspector during PPMSB
Phase 3 Turnaround 2004.
5. REFERENCE
Page 9 of 9