0% found this document useful (0 votes)
74 views

Test Room Unit Spares (Wag-7) : DATE: - 07.05.2005

The document summarizes spare parts information for various locomotive equipment for WAG-7 and WAG-9 locomotives. It includes the number of locomotives held, the required spare percentage, the number of spares available and ready, the total defective equipment, and remarks on the status of equipment repairs. Locomotives under observation for issues like DGA readings and humming sounds are also listed. The final page provides spare part information specifically for WAG-9 locomotives, including the number of locomotives held, spare parts requirements, availability and status of requests.

Uploaded by

anon-469520
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views

Test Room Unit Spares (Wag-7) : DATE: - 07.05.2005

The document summarizes spare parts information for various locomotive equipment for WAG-7 and WAG-9 locomotives. It includes the number of locomotives held, the required spare percentage, the number of spares available and ready, the total defective equipment, and remarks on the status of equipment repairs. Locomotives under observation for issues like DGA readings and humming sounds are also listed. The final page provides spare part information specifically for WAG-9 locomotives, including the number of locomotives held, spare parts requirements, availability and status of requests.

Uploaded by

anon-469520
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 5

Page 1

TEST ROOM UNIT SPARES (WAG-7) DATE: -07.05.2005


Sr. EQPT Hol Spare Req Spare Spare Total Defective Remarks
No. d % nos. avbl. ready Total Bey Heavy Repairs
Ing Rep Shed Shop Trade
POH/
TMW
01 TFP 141 07 10 06+01(C 1) 01 Spared
GL by CGL
SPARE) included in
R/Spare.
2) 03 Nos. sent
to H.V. on
CGL -- 01 00 01 00 00 00 01 dated. 13.09.04
3) 01 sent to
BHEL -- 04 01 03 01 00 00 02 CGL for U/C
rep. Since --/--
NGEF -- 01 00 01 00 00 00 01

OTHERS -- 01 01 00 00 00 00 00
WAG-9 09 01+01 00 02 00 00 00 02 1) 02 U/W of
M/s. BHEL &
CGL of POH
BSL
GR 141 02 under contact
ABB 119 04 06 05 02 03 00 01 00 02 given to M/s BT
022 01 00 00 00 00 00 00 on 25.04.05
GANZ
03 SMGR 141 04 06 04 U/C
ABB 119 05 02 03 00 03 00 00 Received on
GANZ 022 04 00 04 00 00 00 04 date. 06.05.05
04 VCB 141
GEC 07 10 10 02 08 03 05 00 00
Single WAG-9 02 00 02 02
Bottle
VCB
(AAL/BT)
05 RF 141 07 10 11 02 RF Block
BLOCK handed overed
KEC 089 05 00 05 03 02 00 00 to DRI as U/C
DRI 035 03 02 01 01 00 00 00 repair on dated
BHEL 007 01 00 01 00 00 00 01 28.01.2005
CGL 010 02 00 02 01 00 00 01

Test Room Unit Spares.5.doc



Page 2

Sr. EQPT Hol Spare Req Spare Spare Total Defective Remarks
No d % nos. avbl ready Total Bey Heavy Repairs
Ing Rep Shed Shop Trade
POH/
TMW
06 RSI 282 10 14 08 05 03 01 02 00 00
07 SL-30 282 07 20 19 01 18 *01+ 00 13 00 11 nos. sent to
05 TMW/NKRD
(U/ till date.
W) *01 U/W of
Stes Stesalit on
alit shop floor.

08 R118 141 -- -- 10 03 07 05 02 00 00

LOCOS UNDER OBSERVATION OF DGA & HUMMING SOUND TYPE WAG-7

TARAP BT
REASON NGEF BHEL CGL HIND HIGH VOLT
UR
DGA –VE. 27305 (98) 27411 -- -- -- 31070
27121(96) ( C2H2=5 -- -- --
27128(98) PPM) -- -- --
27407
27433
27350 (97) (
C2H2=5
PPM)
HUMMING -- -- -- -- -- --
SOUND

Test Room Unit Spares.5.doc



Page 3
TEST ROOM UNIT SPARES (WAG-9)
DATE: - 07.05.2005

EQPT Hol Spare Req Spare Spare Total Defective Qty/Reqn.


Sr. d % nos. avbl. ready Total Bey Heavy Repairs No., date/
No. Ing Rep Shed Shop Trade Remarks/
POH/ Status
TMW

01 TFP 25 05 01 01 00 02 00 00 00 01 RSP, Qty: -


(WAG-9) 15 05 01 01 01 no
01 no
received
and sent to
BSL
02 Traction 30 2.5 01 02 (½) (½) (½) PB no.
Converter 50 2.5 01 02 Loco Loc L 515/04-05
set o set oco 01 no will
set be supplied
in 05-06
and 02 nos.
proposal in
06-07
03 Auxiliary 45 03 01 03 PB No.
Converter 75 03 02 03 515/04-05
for 01 set
will be
supplied in
06-07 and
01 set
proposed
in 06-07
04 Capacitor 45 05 02 00 TR-458 for
Bank for 75 05 04 00 01 set Dt.
Auxiliary 19.10.04 is
Converter submitted
to CEE
office on
11.04.05
05 Angle 25 10 00 21.11.03
Transmitter Loco Qty: -
set 04+01 no.
06 Earthing 15 05 01 00 TB-
switch for 25 05 01 00 27.02.04
VCB File no.
17048029
LT
05.02.05
for 01

Test Room Unit Spares.5.doc



Page 4
EQPT Hol Spare Req Spare Spare Total Defective Qty/Reqn.
Sr. d % nos. avbl. ready Total Bey Heavy Repairs No., date/
No. Ing Rep Shed Shop Trade Remarks/
POH/ Status
TMW

07 Oil cooler 30 10 03 00 TR-204 for


Radiator 50 10 03 00 01 No. Dt.
06.12.03
Under
scrutiny
File no.
17048051
AT
16.11.04
08 Capacitor 25 00 06.12.03
for Loco
Harmonic set
Filter
09 Single 15 10 02 02 00 01 -- 01 TR-268 for
Bottle 25 10 03 02 01 No. Dt.
Vaccume 27.02.04
Circuit file No.
Breaker 17048108
LT
(VCB)
10 Cab Heater 30 10 3 00 00 00 00 00 00 00 TR-307 for
50 10 5 00 05 nos. Dt.
16.04.04
File No.
17058038
11 Valve set 90 10 09 00 TR-464
(ZV-ZV) for 150 10 15 00 23.10.04
Traction Qty: - 02
Converter nos.
12 Valve set 30 10 03 00 TR-445
(ZV-MV) 50 10 05 05 08.10.04
for Traction Qty: - 01
Converter nos.
13 Three Phase 15 05 01 00 TR-446 for
Transformer 25 05 01 00 01 No. Dt.
for Auxiliary 18.10.04 is
Converter submitted
to CEE
office on
11.04.05

Test Room Unit Spares.5.doc



Page 5
EQPT Hol Spare Req Spare Spare Total Defective Qty/Reqn.
Sr. d % nos. avbl. ready Total Bey Heavy Repairs No., date/
No. Ing Rep Shed Shop Trade Remarks/
POH/ Status
TMW

14 Rectifier 45 5 1 00 TR-455
(GG) 75 5 2 00 19.10.04
module for Qty: - 01
WAG-9 loco nos.
Auxiliary
Converter
15 Capacitor 25 00 TR-458
Assly CZ Loco 19.10.04
12.01 for set Qty: - 02
Auxiliary nos.
Converter
16 MUB for 25 00 TR-440
Traction Loco 18.10.04
Converter set Qty :- 01
no.
17 Cab heater 25 01 00 24.01.05
complete Loco
/Ventilation set
18 WRE 135 05 07 00
Module 225 05 11 00

Test Room Unit Spares.5.doc


You might also like