Dryer Calculation
Dryer Calculation
With the rapid growth in capacity and operation speed of personal computers, an
increase is noted in the development of various software programs devoted to thermal
drying (Baker and Lababidi, 2000, 2001; Baker et al., 2004; Kemp et al., 1887; Marinos -
Kouris et al., 1996; Maroulis et al., 2007; Menshutina and Kudra, 2001). Kemp (2007)
provided an excellent overview of the state-of-the art on drying softwares. He not only
described available software packages but also discussed issues of general matter such
as the strategy for the development of drying softwares, barriers in software design and
implementation, limitations and challenges on the progress, and future developments.
Interestingly, the existing software and calculation tools do not consider energy aspects
even though the drying is recognized as a particularly energy -intensive unit operation.
To fill this gap, an attempt was made to develop a computer -based tool allowing the
calculation of energy use in industrial dryers, evaluate the potential for energy savings,
and analyze options for reducing energy consumption.
Essentially, the calculation of drying energy consumption is based on the drying gas
parameters. However, determination of the attainable top-line dryer for indices such as
specific energy consumption and energy efficiency, as well as an analysis of options for
reducing energy consumption are based on material properties (e.g., specific heat,
sorption isotherms). As such properties are not readily available, the tool allows
calculation of needed parameters or, at least, the use of properties of the materials most
similar to the drying material. An example is the equilibrium moisture content tabulated
for representative materials.
Because of the page format constraints, a more detailed description of the tool will be
presented in the paper published in a special edition of Drying Technology.
The tool was developed in Excel -VBA, but after thorough verification, it will migrated to a
VB.net platform.
The energy efficiency (dž) relates the energy used for moisture evaporation at the feed
temperature (E ) to the total energy supplied to the dryer (E )
Regarding only the energy used to heat drying air which enters a single -pass theoretical
convective dryer, Equation 1 can be rewritten as
The specific air consumption (W*) is given by mass of air required to evaporate 1 kg of
water
A theoretical dryer is defined as a dryer with no heat spent for heating the material and
transportation equipment, heat is not supplied to the internal heater, heat is not l ost to
the ambient atmosphere, and inlet material temperature is equal to 0°C. Thus, the
energy efficiency of a real dryer can be determined from the following relation:
For low humidity and low temperature convective drying, the energy efficiency can be
approximated by thermal efficiency (dž|)
The thermal (energy) efficiency does not indicate how good the dryer is unless it is
compared to the maximum thermal efficiency (dž| )
The departure of a thermal efficiency of a real dryer from the maximum one is quantified
by the efficiency ratio
For a given evaporation rate, saturation of the exhaust air (Y ï ) can be attained when
the air flow is minimal, yet securing both heat and hydrody namic requirements. Thus,
When drying hygroscopic materials, the relative humidity of the air stream at any point
in the dryer should be lower than the equilibrium relative humidity at this point. Thus,
for such materials the maximum energy efficiency is restricted not by saturation but by
the equilibrium humidity (Y ï ) determined from sorption isotherms
Baker and McKenzie (2005) derived the following expression for the specific energy
consumption of a theoretical dryer, which indicates that the specific energy consumption
of an unspecified indirectly -heated convective dryer depends on the temperature and
humidity of the outlet air and the heat loss
where ƩH is the latent heat of evaporation at 0°C, taken as the reference temperature.
The parameter dž in Equation 12 is called the thermal loss factor of the dryer, and
defined as
For an adiabatic dryer dž = 0 so Equation 12 reduces to
A difference between specific energy consumption of the real and theoretical dryers
operated at the same exhaust air temperature and humidity gives the excess specific
energy consumption, which is a measure of the wasted energy due to heat losses and
other inefficiencies (Baker and McKenzie, 2005)
Baker, C. G. J., H. M. S. Lababidi and K. Masters (2004). A fuzzy expert system for the
selection of spray-drying equipment. Drying Technology, 19(8), 1851 -1873.
Baker, C. G. J., and K.A. McKenzie (2005). Energy consumption of industrial spray
dryers. Drying Technology, 23 (1&2), 365 -386.
Baker, C. G. J. (2005). An evaluation of factors influencing the energy -efficient operation
of well-mixed fluidized bed dryers. Proc. 3rd Inter-American Drying Conference
(IADC2005), 21-23 Aug. 2005. Montreal, Canada. Paper XIV -1.
Baker, C. G. J. (2005). Energy-efficient dryer operation-an update on developments.
Drying Technology, 23(9 -11), 2071-2087.
Baker, C. G. J., A. R. Khan, Y. I. Ali and K. Damyar (2006). Simulation of plug flow
fluidized bed dryers. Chemical Engineering and Processing, 45, 641 -651.
Gong, Z-X. and A. S. Mujumdar (2008). Software for design and analysis of drying
systems. rying Technology, 26 (7), 884 -894.
Kemp, I. C., I. A. G. Snowball and R. E. Bahu (1997). An expert system for dryer
selection. Proc. ECCE-1, Vol. 2 175-182.
Kemp, I. C. (2007). Drying software: past, present and future. Drying Technology, 25
(7), 1249-1263.
Pakowski, Z. (1994). dryPAk v1.1. Program for psychrometric and drying computation.
Drying Technology, 12 (7), 1765 -1768.
v
c Heat capacity, kJ/(kg K)
d.
Dry basis
b.
E Energy, J
E Specific energy consumption, kJ/kg HïO
Specific energy consumption of adiabatic dryer, kJ/kg
E
HïO
E Excess specific energy consumption, kJ/kg HïO
F Feed rate (dry basis), kg/s
ƩH Latent heat of vaporization, kJ/kg
I Enthalpy, kJ/kg
ƶQ Heat losses, kJ/kg H ïO
Q Heat rate, kJ/s
t Time, s
T Temperature, K (°C)
W* Specific air consumption, kg air/kg H ïO
W Flow rate, kg/s
Material moisture content (d. b.), kg H ïO/kg dry
X
material
Y Air humidity, kg H ïO/kg dry air
dž Efficiency, -
X Efficiency ratio -
a Ambient
AS Adiabatic saturation
ev Evaporation
g Gas (air)
h Heater
l Losses
max Maximum
ref Reference
t Total
T Thermal
WB Wet bulb
1 Inlet
2 Outlet
eq Equilibrium
t Theoretical
sat Saturation
Fig. 2. Input data sheet.
Fig. 3. Results of calculations.