Scrubber Design (Packed Column)
Scrubber Design (Packed Column)
Component to be scrubbed
Component Name = HCL Vap
Component flow rate = 70 Kg/h
% comp. in air/gas = 6 % (v/v) (presumed) / (given by client) / (by process cal.)
Molecular weight of comp. = 36.5
Sheet 1 of 10
Calculations
Since larger flow quantities are at the bottom for an absorber, the diameter will be chosen to
accommodate the bottom conditions.
If gas flow rate is given in kg/h If gas flow rate is given in m3/h
Select vol. flow rate and mass flow rate from above,
Selected mass flow rate = 0.28 Kg/s
Selected vol. Flow rate = 0.23 m3/s
Selected molar flow rate = 0.01 Kmol/s
Therefore, gas density = 1.1846 Kg/m3 (mass flow rate / vol. Flow rate)
Using 0.00497 as ordinate, Refer fig.6.34 using a gas pressure drop of 147.1 (N/m2)/m
= 1.6665 Kg / m2.s
Tower c/s area = 0.1667 m2 ( c/s area = mass flow rate / G' )
Sheet 2 of 10
Corresponding c/s area = 0.1963 m2
Pressure drop for irrigated = 470.72 N/m2 (pressure drop per m packing x total ht. of packing)
packing
Delta P = CD G' 2
Z G
= 142.89 N/m2
Pressure drop for packing = 613.61 N/m2 (irrigated packing + dry packing)
Pressure drop for internals = 25 mmWC (packing supports and liquid distributors)
= 245.17 N/m 2
Power for fan motor = 0.34 kW (fan power output / motor efficiency)
= 0.45 hp
Sheet 3 of 10
COLUMN DIAMETER / HYDRAULIC CHECK
K4 at flooding = 6.50
= 3.7763 kg/m2.s
Conclusion
Generally packed towers are designed for 50% -- 85% flooding.
If flooding is to be reduced,
(i) Select larger packing size and repeat the above steps.
OR
(ii) Increase the column diameter and repeat the above steps.
Sheet 4 of 10
HETP PREDICTION
n = 1.13080
Calculation
ln HETP = 0.84
HETP = 2.31 ft
= 0.7 m
For separations, less than 15 theoritical stages, a 20% design safety factor can be applied.
For separations, requiring 15 to 25 theoritical stages, a 15% design safety factor can be applied.
Sheet 5 of 10
Table 6.2
Constant for HETP Correlation