Scaling Factors A 10% / 10mm B 1h/ 2000mm 3600s / 2000mm

This document contains information about scaling factors, response rates, dead times, and time constants for two exercises involving a sensor. For Exercise 7, the response rate is 0.25917 s-1, the dead time is 3.6 s, and the time constant is 5.4 s. For Exercise 8, the response rate is 0.022467 s-1, the dead time is 1.8 s, and no time constant is given.

Uploaded by

fatthul hadi
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views

Scaling Factors A 10% / 10mm B 1h/ 2000mm 3600s / 2000mm

This document contains information about scaling factors, response rates, dead times, and time constants for two exercises involving a sensor. For Exercise 7, the response rate is 0.25917 s-1, the dead time is 3.6 s, and the time constant is 5.4 s. For Exercise 8, the response rate is 0.022467 s-1, the dead time is 1.8 s, and no time constant is given.

Uploaded by

fatthul hadi
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Exercise 7

Scaling factors
a =10% / 10mm
b = 1h/ 2000mm = 3600s / 2000mm

Response rate,
RR=

tan a tan 75
10
3600 mm
=

=0.25917 s1
MV b
8
10 mm
2000 s

Dead time,
T d=T d ( length ) b=2 mm

3600 s
=3.6 s
2000 mm

Time constant.
T c =T c ( length ) (3 mm)

3600 s
=5.4 s
2000 mm

Exercise 8
Scaling factors
a =10% / 10mm
b = 1h/ 2000mm = 3600s / 2000mm

Response rate,
R=

tan a tan 20
10
3600 mm
1
=

=0.022467 s
MV b
9
10 mm
2000 s

Dead time.
T d=T d ( length ) b=1 mm

3600 s
=1.8 s
2000 mm