Calculations On An Adiabatic Continuous Dryer
Calculations On An Adiabatic Continuous Dryer
1. On the Tools menu, click Options, then click the Calculation tab and tick on the Iteration
2. In the spreadsheet "Calculations"
a. Insert input values in the yellow cells
b. Turn the "SWITCH" ON (set the value in the cell G2 (red cell) equal to 1 and press ENTER)
c. Iterate (by pressing F9) until the values in the green cells are constant. Read the results in the gree
d. To recalculate for different parameter values turn the "SWITCH" OFF (set the value in the cell G2 e
press ENTER)
the results in the green cells
value in the cell G2 equal to 0 and press ENTER). Repeat steps 2a to 2c
Input data
Air before heater
Temperature
Relative humidity
T=
RH=
20 oC
60.0%
TGi=
200 oC
RHo=
10.0%
F=
Yi=
5000 kg/h
50.0%
Yo=
4.0%
Results
Air mass flow rate
Ratio of air to product mass flow rate
Volumetric air flow rate at inlet
Air temperature at outlet
Heat reguirements
Specific Heat Consumption
mG=
mG/mF=
q=
TGo=
54453 kg d.a/h
21.8
45787 m3/h
93.3 oC
Q= 10011471 kJ/h
SHC=
4178.7 kJ/kg water evapor.
Control panel
SWITCH=
Properties of air
Dry bulb temperature
Wet bulb temperature
Room
T=
Tw=
Tdp=
Air at
Air at
air
20.0
inlet
200.0
outlet
93.3
15.0
47.3
47.3
11.8
0.009
11.8
0.009
41.0
0.053
0.011
60.0%
0.074
0.1%
0.074
10.0%
Dew-point temperature
Humidity at T
Saturation humidity at Tw
W=
W w=
Relative humidity
RH=
p=
pw T=
1403
1403
7919
2338
1563054
79521
pw Tw=
1706
10774
10774
7790
Enthalpy of air
1384
1384
0.0086
0.0087
42.3
226.1
234.9
H=
w=
2467
2390
2390
Humid heat
cs=
1.021
1.021
1.104
Humid volume
vH=
0.841
1.357
1.125
0.00
0.00
0.00
0.00
0.00
0.00
Calculations
Moisture condent of product at inlet (dry basis)
Xi=
Xo=
mF=
2500 kg d.s./h
TGo=
93.3 oC
mG=
54453 kg d.a/h