169
APPENDIX 1
IEEE 5-BUS SYSTEM DATA
Table A1.1 Bus Data for IEEE 5-Bus System
Generation
Load
Megawatts Megavars Megawatts Megavars
0
0
0
0
Bus Code
P
Assumed Bus
Voltage
1.06 + j0.0
2
3
4
1.0 + j0.0
1.0 + j0.0
1.0 + j0.0
40
0
0
30
0
0
20
45
40
10
15
5
1.0 + j0.0
60
10
Table A1.2 Line Data for IEEE 5-Bus System
Line impedance Zpq
Line charging
Bus Code
pq
R per unit
X per unit
Y pq / 2
1-2
0.02
0.06
X per unit
1-3
2-3
2-4
2-5
0.08
0.06
0.06
0.04
0.24
0.25
0.18
0.12
0.0 + j0.025
0.0 + 0.020
0.0 + j0.020
0.0 + j0.015
3-4
4-5
0.01
0.08
0.03
0.24
0.0 + j0.010
0.0 + j0.025
170
Table A1.3 MW Limits for Branches in IEEE 5 Bus System
Line
1-2
1-3
MW Limit (P.u)
0.8
0.3
2-3
2-4
0.2
0.2
2-5
3-4
4-5
0.6
0.1
0.1
171
APPENDIX 2
IEEE 14-BUS SYSTEM DATA
Table A2.1 Bus Data for IEEE 14-Bus System
Bus
Bus Voltage
Magnitude Phase Angle
Generation
Load
Reactive
MVAR
Real
MW
Reactive
MVAR
Per Unit
Degrees
Real
MW
1.060
0.0
232.4
- 16.9
0.0
0.0
1.045
- 4.98
40.0
42.4
21.7
12.7
1.010
- 12.72
0.0
23.4
94.2
19.0
1.019
- 10.33
0.0
0.0
47.8
3.9
1.020
- 8.78
0.0
0.0
7.6
1.6
1.070
- 14.22
0.0
12.2
11.2
7.5
1.062
- 13.37
0.0
0.0
0.0
0.0
1.090
- 13.36
0.0
17.4
0.0
0.0
1.056
- 14.94
0.0
0.0
29.5
16.6
10
1.051
- 15.10
0.0
0.0
9.0
5.8
11
1.057
- 14.79
0.0
0.0
3.5
1.8
12
1.055
- 18.07
0.0
0.0
6.1
1.6
13
1.050
- 15.16
0.0
0.0
13.5
5.8
14
1.036
- 16.04
0.0
0.0
14.9
5.0
No.
172
Table A2.2 Line Data for IEEE 14-Bus System
Line impedance
Line
Between
No
Buses
R per unit
12
0.01938
0.05917
0.02640
23
0.04699
0.19797
0.02190
24
0.05811
0.17632
0.01870
15
0.05403
0.22304
0.02460
25
0.05695
0.17388
0.01700
34
0.06701
0.17103
0.01730
45
0.01335
0.04211
0.0064
56
0.0
0.25202
0.0
47
0.0
0.20912
0.0
10
78
0.0
0.17615
0.0
11
49
0.0
0.55618
0.0
12
79
0.0
0.11001
0.0
13
9 10
0.03181
0.08450
0.0
14
6 11
0.09498
0.19890
0.0
15
6 12
0.12291
0.25581
0.0
16
6 13
0.06615
0.13027
0.0
17
9 14
0.12711
0.27038
0.0
18
10 11
0.8205
0.19207
0.0
19
12 13
0.22092
0.19988
0.0
20
13 14
0.17093
0.34802
0.0
X per unit
Half Line Charging
Susceptance per unit
173
Table A2.3 Transformer Data
Transformer
1
2
Between Buses
4-7
4-9
Tap Setting
0.978
0.969
5-6
0.932
Table A2.4 Shunt Capacitor Data
Bus Number
9
Susceptance Per Unit
0.190
Table A2.5 Regulated Bus Data (P V Buses)
Bus No
Voltage
Magnitude per
unit
Reactive Power Limits
1.045
Minimum
MVAR
- 40.0
Maximum
MVAR
50.0
1.010
0.0
40.0
1.070
- 6.0
24.0
1.090
- 6.0
24.0
174
Table A2.6 MW Limits for Branches in IEEE 14 Bus System
12
23
MW Limit
(P.u)
0.6
0.7
24
0.8
15
25
34
45
0.5
0.4
0.3
0.2
56
47
78
0.5
0.4
0.2
49
79
9 10
6 11
0.2
0.2
0.2
0.3
6 12
6 13
0.2
0.2
9 14
10 11
0.2
0.2
12 13
13 14
0.2
0.2
Line
175
APPENDIX 3
6 -BUS SYSTEM DATA
Table A3.1 Bus Data for 6-Bus System
Bus No.
Bus Type
Swing
2
3
4
5
Gen
Gen
Load
Load
Load
Voltage
Profile
1.05
1.05
1.07
Pgen
Pload
Qload
(P.U MW)
(P.U MW)
(P.U MVAR)
0.50
0.60
0.0
0.0
0.0
0.0
0.7
0.7
0.0
0.0
0.7
0.7
0.0
0.7
0.7
Table A3.2 Line Data for 6-Bus System
From Bus
1
1
1
To Bus
2
4
5
R(pu)
0.10
0.05
0.08
X(pu)
0.20
0.20
0.30
BCAP(pu)
0.02
0.02
0.03
2
2
2
3
4
5
0.05
0.05
0.10
0.25
0.10
0.30
0.03
0.01
0.02
2
3
3
4
6
5
6
5
0.07
0.12
0.02
0.20
0.20
0.30
0.10
0.40
0.025
0.025
0.01
0.04
0.10
0.30
0.03
176
Table A3.3 MW Limits for Branches in 6-Bus System
Line
MW Limit (P.u)
1-2
0.3
1-4
0.5
1-5
0.4
2-3
0.2
2-4
0.4
2-5
0.2
2-6
0.3
3-5
0.2
3-6
0.6
4-5
0.2
5-6
0.2
177
APPENDIX 4
IEEE 30 BUS SYSTEM DATA
Table A4.1 Bus Data for IEEE 30-Bus System
Bus
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Bus Voltage
Magnitude Phase angles
(Degrees)
(P.U)
1.0500
0.0
1.0338
-2.7339
1.0313
-4.6815
1.0263
-5.6077
1.0058
-8.9930
1.0208
-6.4547
1.0069
-8.0244
1.0230
-6.4733
1.0332
-8.0300
1.0183
-9.9268
1.0913
-6.1345
1.0399
-9.4036
1.0883
-8.2049
1.0236
-10.3086
1.0179
-10.3600
1.0235
-9.90280
1.0144
-10.1356
1.0057
-10.9253
1.0017
-11.0615
1.0051
-10.8310
1.0061
-10.4047
1.0069
-10.3936
1.0053
-10.7221
0.9971
-10.8465
1.0086
-10.9074
0.9908
-11.3345
1.0245
-10.6624
1.0156
-6.86710
1.0047
-11.8893
0.9932
-12.7699
Generation
Real
Reactive
MW
MVAR
138.48
-2.79
57.56
2.47
0.0
0.0
0.0
0.0
24.56
22.57
0.0
0.0
0.0
0.0
35.0
34.84
0.0
0.0
0.0
0.0
17.93
30.78
0.0
0.0
16.91
37.83
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
Load
Real
Reactive
MW
MVAR
0.0
0.0
21.7
12.7
2.4
1.2
7.6
1.6
94.2
19.0
0.0
0.0
22.8
10.9
30.0
30.0
0.0
0.0
5.8
2.0
0.0
0.0
11.2
7.5
0.0
0.0
6.2
1.6
8.2
2.5
3.5
1.8
9.0
5.8
3.2
0.9
9.5
3.4
2.2
0.7
17.5
11.2
0.0
0.0
3.2
1.6
8.7
6.7
0.0
0.0
3.5
2.3
0.0
0.0
0.0
0.0
2.4
0.9
10.6
1.9
178
Table A4.2 Line Data for IEEE 30-Bus System
Line
No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
Between
Buses
12
13
24
34
25
26
46
57
67
68
69
6 10
9 10
4 12
12 14
12 15
12 16
14 15
16 17
15 18
18 19
19 20
10 20
10 17
10 21
10 22
21 22
15 23
22 24
23 24
24 25
25 27
28 27
27 29
27 30
29 30
8 28
6 28
9 11
12 13
25 26
Line impedance
R per unit
X per unit
0.0192
0.0575
0.0452
0.1652
0.0570
0.1737
0.0132
0.0379
0.0472
0.1983
0.0581
0.1763
0.0119
0.0414
0.0460
0.1160
0.0267
0.0820
0.0120
0.0420
0.0
0.2080
0.0
0.5560
0.0
0.1100
0.0
0.2560
0.1231
0.2559
0.0662
0.1304
0.0945
0.1987
0.2210
0.1997
0.0524
0.1923
0.1073
0.2185
0.0639
0.1292
0.0340
0.0680
0.0936
0.2090
0.0324
0.0845
0.0348
0.0749
0.0727
0.1499
0.0116
0.0236
0.1000
0.2020
0.1150
0.1790
0.1320
0.2700
0.1885
0.3292
0.1093
0.2087
0.0
0.3960
0.2198
0.4153
0.3202
0.6027
0.2399
0.4533
0.0636
0.2000
0.0169
0.0599
0.0
0.2080
0.0
0.1400
0.2544
0.3800
Half Line Charging
Susceptance per unit
0.0528
0.0408
0.0368
0.0084
0.0418
0.0374
0.0090
0.0204
0.0170
0.0090
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.4028
0.0130
0.0
0.0
0.0
179
Table A4.3 MW Limits for Branches in IEEE 30-Bus System
Line
12
13
24
34
25
26
46
57
67
68
69
6 10
9 10
4 12
12 14
12 15
12 16
14 15
16 17
15 18
18 19
19 20
10 20
10 17
10 21
10 22
21 22
15 23
22 24
23 24
24 25
25 27
28 27
27 29
27 30
29 30
8 28
6 28
9 11
12 13
25 26
MW Limit (pu)
1.0400
1.0400
0.5200
1.0400
1.0400
0.5200
0.7200
0.5600
1.0400
0.2560
0.5200
0.2560
0.5200
0.5200
0.2560
0.2560
0.2560
0.1280
0.1280
0.1280
0.1280
0.2560
0.2560
0.2560
0.2560
0.2560
0.2560
0.1280
0.1280
0.1280
0.4800
0.1280
0.5200
0.1280
0.1280
0.1280
0.2560
0.2560
0.5200
0.5200
0.1280
180
APPENDIX 5
IEEE 118 BUS SYSTEM DATA
Table A5.1 Bus Data for IEEE 118-Bus System
Bus
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Bus Type
Gen
Load
Load
Gen
Load
Gen
Load
Gen.
Load
Gen.
Load
Gen.
Load
Load
Gen.
Load
Load
Gen.
Gen.
Load
Load
Load
Load
Gen.
Gen.
Gen.
Gen.
Load
Load
Load
Gen.
Gen.
Load
Voltage
(P.u)
0.955
0.971
0.968
0.998
1.002
0.99
0.989
1.015
1.043
1.05
0.985
0.99
0.968
0.984
0.97
0.984
0.995
0.973
0.963
0.958
0.959
0.97
1
0.992
1.05
1.015
0.968
0.962
0.963
0.968
0.967
0.964
0.972
Pgen
(P.u)
0
0
0
0
0
0
0
0
0
4.5
0
0.85
0
0
0
0
0
0
0
0
0
0
0
0
2.2
3.14
0
0
0
0
0.07
0
0
Pload
(P.u)
0.51
0.2
0.39
0.39
0
0.52
0.19
0.28
0
0
0.7
0.47
0.34
0.14
0.9
0.25
0.11
0.6
0.45
0.18
0.14
0.1
0.07
0.13
0
0
0.71
0.17
0.24
0
0.43
0.59
0.23
Qload
(P.u)
0.27
0.09
0.1
0.12
0
0.22
0.02
0
0
0
0.23
0.1
0.16
0.01
0.3
0.1
0.03
0.34
0.25
0.03
0.08
0.05
0.03
0
0
0
0.13
0.07
0.04
0
0.27
0.23
0.09
181
Table A5.1 (Continued)
Bus
No.
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
Bus Type
Gen.
Load
Gen.
Load
Load
Load
Gen.
Load
Gen.
Load
Load
Load
Gen.
Load
Load
Gen.
Load
Load
Load
Load
Gen.
Gen.
Gen.
Load
Load
Gen.
Load
Gen.
Gen.
Load
Load
Gen.
Gen.
Load
Load
Swing
Gen.
Load
Gen.
Gen.
Gen.
Load
Voltage
(P.u)
0.986
0.981
0.98
0.992
0.962
0.97
0.97
0.967
0.985
0.978
0.985
0.987
1.005
1.017
1.021
1.025
1.001
0.967
0.957
0.946
0.955
0.952
0.954
0.971
0.959
0.985
0.993
0.995
0.998
0.969
0.984
1.005
1.05
1.02
1.003
1.035
0.984
0.987
0.98
0.991
0.958
0.967
Pgen
(P.u)
0
0
0
0
0
0
0
0
0
0
0
0
0.19
0
0
2.04
0
0
0
0
0.48
0
0
0
0
1.55
0
1.6
0
0
0
3.91
3.92
0
0
5.164
0
0
0
0
0
0
Pload
(P.u)
0.59
0.33
0.31
0
0
0.27
0.66
0.37
0.96
0.18
0.16
0.53
0.28
0.34
0.2
0.87
0.17
0.17
0.18
0.23
1.13
0.63
0.84
0.12
0.12
2.77
0.78
0
0.77
0
0
0
0.39
0.28
0
0
0.66
0
0.12
0.06
0.68
0.47
Qload
(P.u)
0.26
0.09
0.17
0
0
0.11
0.23
0.1
0.23
0.07
0.08
0.22
0.1
0
0.11
0.3
0.04
0.08
0.05
0.11
0.32
0.22
0.18
0.03
0.03
1.13
0.03
0
0.14
0
0
0
0.18
0.07
0
0
0.2
0
0
0
0.27
0.11
182
Table A5.1 (Continued)
Bus
No.
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
Bus Type
Gen.
Gen.
Load
Load
Gen.
Load
Load
Load
Load
Gen.
Load
Gen.
Load
Gen.
Gen.
Gen.
Gen.
Load
Load
Load
Load
Load
Load
Gen.
Gen.
Load
Load
Gen.
Gen.
Gen.
Load
Gen.
Load
Load
Gen.
Gen.
Gen.
Gen.
Load
Load
Gen.
Load
Load
Voltage
(P.u)
0.943
1.006
1.003
1.009
1.04
0.997
0.989
0.985
0.98
0.985
0.987
1.015
0.987
1.005
0.985
0.98
0.993
0.987
0.991
0.981
0.993
1.011
1.024
1.01
1.017
0.993
0.991
1.001
0.971
0.965
0.962
0.952
0.967
0.967
0.973
0.98
0.975
0.993
0.96
0.96
1.005
0.974
0.949
Pgen
(P.u)
0
0
0
0
4.77
0
0
0
0
0
0
0.04
0
6.07
0
0
0
0
0
0
0
0
0
0
2.52
0
0
0.4
0
0
0
0
0
0
0
0.36
0
0
0
0
0
0
0
Pload
(P.u)
0.68
0.61
0.71
0.39
1.3
0
0.54
0.2
0.11
0.24
0.21
0
0.48
0
1.63
0.1
0.65
0.12
0.3
0.42
0.38
0.15
0.34
0.42
0.37
0.22
0.05
0.23
0.38
0.31
0.43
0.5
0.02
0.08
0.39
0
0.68
0.06
0.08
0.22
1.84
0.2
0.33
Qload
(P.u)
0.36
0.28
0.26
0.32
0.26
0
0.27
0.1
0.07
0.15
0.1
0
0.1
0
0.42
0
0.1
0.07
0.16
0.31
0.15
0.09
0.08
0
0.18
0.15
0.03
0.16
0.25
0.26
0.16
0.12
0.01
0.03
0.3
0
0.13
0
0.03
0.07
0
0.08
0.15
183
Table A5.2 Line Data for IEEE 118-Bus System
Bus
From To
1
2
1
3
4
5
3
5
5
6
6
7
8
9
8
5
9
10
4
11
5
11
11
12
2
12
3
12
7
12
11
13
12
14
13
15
14
15
12
16
15
17
16
17
17
18
18
19
19
20
15
19
20
21
21
22
22
23
23
24
23
25
26
25
25
27
27
28
28
29
30
17
8
30
26
30
Line Flow
Limit (MW)
15
48
129
85
111
44
551
423
557
80
97
43
41
12
21
44
23
1
5
9
130
22
100
24
13
14
36
54
67
10
203
113
179
41
20
289
93
280
R (P.u)
0.0303
0.0129
0.00176
0.0241
0.0119
0.00459
0.00244
0
0.00258
0.0209
0.0203
0.00595
0.0187
0.0484
0.00862
0.02225
0.0215
0.0744
0.0595
0.0212
0.0132
0.0454
0.0123
0.01119
0.0252
0.012
0.0183
0.0209
0.0342
0.0135
0.0156
0
0.0318
0.01913
0.0237
0
0.00431
0.00799
X (P.u)
0.0999
0.0424
0.00798
0.108
0.054
0.0208
0.0305
0.0267
0.0322
0.0688
0.0682
0.0196
0.0616
0.16
0.034
0.0731
0.0707
0.2444
0.195
0.0834
0.0437
0.1801
0.0505
0.0493
0.117
0.0394
0.0849
0.097
0.159
0.0492
0.08
0.0382
0.163
0.0855
0.0943
0.0388
0.0504
0.086
BCAP
(P.u)
0.0127
0.00541
0.00105
0.0142
0.00713
0.00275
0.581
0
0.615
0.00874
0.00869
0.00251
0.00786
0.0203
0.00437
0.00938
0.00908
0.03134
0.0251
0.0107
0.0222
0.0233
0.00649
0.00571
0.0149
0.00505
0.0108
0.0123
0.0202
0.0249
0.0432
0
0.0882
0.0108
0.0119
0
0.257
0.454
184
Table A5.2 (Continued)
Bus
From To
17
31
29
31
23
32
31
32
27
32
15
33
19
34
35
36
35
37
33
37
34
36
34
37
38
37
37
39
37
40
30
38
39
40
40
41
40
42
41
42
43
44
34
43
44
45
45
46
46
47
46
48
47
49
42
49
42
49
45
49
48
49
49
50
49
51
51
52
52
53
53
54
49
54
49
54
Line Flow
Limit (MW)
18
11
116
37
16
9
4
1
42
20
38
118
304
69
55
78
34
19
15
27
21
2
41
45
39
18
12
81
81
62
44
67
83
36
13
16
47
47
R (P.u)
0.0474
0.0108
0.0317
0.0298
0.0229
0.038
0.0752
0.00224
0.011
0.0415
0.00871
0.00256
0
0.0321
0.0593
0.00464
0.0184
0.0145
0.0555
0.041
0.0608
0.0413
0.0224
0.04
0.038
0.0601
0.0191
0.0715
0.0715
0.0684
0.0179
0.0267
0.0486
0.0203
0.0405
0.0263
0.073
0.0869
X (P.u)
0.1563
0.0331
0.1153
0.0985
0.0755
0.1244
0.247
0.0102
0.0497
0.142
0.0268
0.0094
0.0375
0.106
0.168
0.054
0.0605
0.0487
0.183
0.135
0.2454
0.1681
0.0901
0.1356
0.127
0.189
0.0625
0.323
0.323
0.186
0.0505
0.0752
0.137
0.0588
0.1635
0.122
0.289
0.291
BCAP
(P.u)
0.01995
0.00415
0.05865
0.01255
0.00963
0.01597
0.0316
0.00134
0.00659
0.0183
0.00284
0.00492
0
0.0135
0.021
0.211
0.00776
0.00611
0.0233
0.0172
0.03034
0.02113
0.0112
0.0166
0.0158
0.0236
0.00802
0.043
0.043
0.0222
0.00629
0.00937
0.0171
0.00698
0.02029
0.0155
0.0369
0.0365
185
Table A5.2 (Continued)
Bus
From To
54
55
54
56
55
56
56
57
50
57
56
58
51
58
54
59
56
59
56
59
55
59
59
60
59
61
60
61
60
62
61
62
63
59
63
64
64
61
38
65
64
65
49
66
49
66
62
66
62
67
65
66
66
67
65
68
47
69
49
69
68
69
69
70
24
70
70
71
24
72
71
72
71
73
70
74
Line Flow
Limit (MW)
9
23
27
29
45
8
23
38
35
37
43
54
65
140
12
32
190
190
38
227
228
165
165
46
30
11
66
18
70
58
157
135
8
21
2
13
8
20
R (P.u)
0.0169
0.00275
0.00488
0.0343
0.0474
0.0343
0.0255
0.0503
0.0825
0.0803
0.04739
0.0317
0.0328
0.00264
0.0123
0.00824
0
0.00172
0
0.00901
0.00269
0.018
0.018
0.0482
0.0258
0
0.0224
0.00138
0.0844
0.0985
0
0.03
0.00221
0.00882
0.0488
0.0446
0.00866
0.0401
X (P.u)
0.0707
0.00955
0.0151
0.0966
0.134
0.0966
0.0719
0.2293
0.251
0.239
0.2158
0.145
0.15
0.0135
0.0561
0.0376
0.0386
0.02
0.0268
0.0986
0.0302
0.0919
0.0919
0.218
0.117
0.037
0.1015
0.016
0.2778
0.324
0.037
0.127
0.4115
0.0355
0.196
0.18
0.0454
0.1323
BCAP
(P.u)
0.0101
0.00366
0.00187
0.0121
0.0166
0.0121
0.00894
0.0299
0.02845
0.0268
0.02823
0.0188
0.0194
0.00728
0.00734
0.0049
0
0.108
0
0.523
0.19
0.0124
0.0124
0.0289
0.0155
0
0.01341
0.319
0.03546
0.0414
0
0.061
0.05099
0.00439
0.0244
0.02222
0.00589
0.01684
186
Table A5.2 (Continued)
Bus
From To
70
75
69
75
74
75
76
77
69
77
75
77
77
78
78
79
77
80
77
80
79
80
68
81
81
80
77
82
82
83
83
84
83
85
84
85
85
86
86
87
85
88
85
89
88
89
89
90
89
90
90
91
89
92
89
92
91
92
92
93
92
94
93
94
94
95
80
96
82
96
94
96
80
97
80
98
Line Flow
Limit (MW)
1
138
65
76
78
43
57
32
121
55
81
55
55
4
59
31
53
45
21
5
63
89
124
73
139
2
252
79
11
72
65
56
51
24
12
25
33
36
R (P.u)
0.0428
0.0405
0.0123
0.0444
0.0309
0.0601
0.00376
0.00546
0.017
0.0294
0.0156
0.00175
0
0.0298
0.0112
0.0625
0.043
0.0302
0.035
0.02828
0.02
0.0239
0.0139
0.0518
0.0238
0.0254
0.0099
0.0393
0.0387
0.0258
0.0481
0.0223
0.0132
0.0356
0.0162
0.0269
0.0183
0.0238
X (P.u)
0.141
0.122
0.0406
0.148
0.101
0.1999
0.0124
0.0244
0.0485
0.105
0.0704
0.0202
0.037
0.0853
0.03665
0.132
0.148
0.0641
0.123
0.2074
0.102
0.173
0.0712
0.188
0.0997
0.0836
0.0505
0.1581
0.1272
0.0848
0.158
0.0732
0.0434
0.182
0.053
0.0869
0.0934
0.108
BCAP
(P.u)
0.018
0.062
0.00517
0.0184
0.0519
0.02489
0.00632
0.00324
0.0236
0.0114
0.00935
0.404
0
0.04087
0.01898
0.0129
0.0174
0.00617
0.0138
0.02225
0.0138
0.0235
0.00967
0.0264
0.053
0.0107
0.0274
0.0207
0.01634
0.0109
0.0203
0.00938
0.00555
0.0247
0.0272
0.0115
0.0127
0.0143
187
Table A5.2 (Continued)
Bus
From To
80
99
92
100
94
100
95
96
96
97
98
100
99
100
100
101
92
102
101
102
100
103
100
104
103
104
103
105
100
106
104
105
105
106
105
107
105
108
106
107
108
109
103
110
109
110
110
111
110
112
17
113
32
113
32
114
27
115
114
115
68
116
12
117
75
118
76
118
Line Flow
Limit (MW)
24
39
5
2
14
7
28
21
56
49
152
70
41
54
75
61
11
33
30
30
27
76
17
45
87
3
5
12
26
2
230
25
50
9
R (P.u)
0.0454
0.0648
0.0178
0.0171
0.0173
0.0397
0.018
0.0277
0.0123
0.0246
0.016
0.0451
0.0466
0.0535
0.0605
0.00994
0.014
0.053
0.0261
0.053
0.0105
0.03906
0.0278
0.022
0.0247
0.00913
0.0615
0.0135
0.0164
0.0023
0.00034
0.0329
0.0145
0.0164
X (P.u)
0.206
0.295
0.058
0.0547
0.0885
0.179
0.0813
0.1262
0.0559
0.112
0.0525
0.204
0.1584
0.1625
0.229
0.0378
0.0547
0.183
0.0703
0.183
0.0288
0.1813
0.0762
0.0755
0.064
0.0301
0.203
0.0612
0.0741
0.0104
0.00405
0.14
0.0481
0.0544
BCAP
(P.u)
0.0273
0.0236
0.0302
0.00737
0.012
0.0238
0.0108
0.0164
0.00732
0.0147
0.0268
0.02705
0.02035
0.0204
0.031
0.00493
0.00717
0.0236
0.00922
0.0236
0.0038
0.02305
0.0101
0.01
0.031
0.00384
0.0259
0.00814
0.00986
0.00138
0.082
0.0179
0.00599
0.00678