Agenda
1
Systems Overview
T7-1
T7-2
T7-4
T7-1
T7-2
T7-4
M7-8
M7-16
Processors
2 or 4
Up to 8 1
Up to 16 2
Max Cores
32
64
128
256
512
Max Threads
256
512
1,024
2,048
4,096
Max Memory 3
.5 TB
1 TB
2 TB
4 TB
8 TB
2U
3U
5U
Rack / 10U
Rack
LDOMs
LDOMs
LDOMs
LDOMs, PDOMs 1
LDOMs, PDOMs 2
Form
Factor
Domaining
(1)Factory
congured
with
one
(up
to
8
processors)
or
two
(up
to
4
processors
each)
sta9c
physical
domains
(2)1,
2,
3
or
4
recongurable
physical
domains
(3)
Maximum
memory
capacity
is
based
on
32
GB
DIMMs
Copyright
2015,
Oracle
and/or
its
aliates.
All
rights
reserved.
|
T7
Family:
T7-4
T7-1
T7-2
Feature
Form
Factor
Processor
Memory
Integrated
Network
Ports
Internal
Storage
Removable
Media
Management
Ports
USB
Ports
PCI
Express
Slots
Fans
Hot-Swappable
Power
Supplies
Maximum
Power
Consump@on
SPARC T7-1
SPARC T4-1
Power
Bukon
DVD
SAS1
SAS3/NVMe1
SAS5/NVMe3
SAS0
SAS2/NVMe0
SAS4/NVMe2
SAS6
RFID/Serial
Number
2x USB 2.0
SAS7
Status
LEDs
NVM
Express
Technology
(NVMe)
NVMe
=
Non-Vola@le
Memory
host
controller
interface
for
PCIe
bus
NVMe
is
a
high
performance
interface
for
Solid
State
Drives
(SSDs)
Eliminates
the
SAS
Host-Bus
Adapter
by
connec@ng
directly
into
PCIe
bus
Improves
both
random
and
sequen@al
performance
Reduced
latency,
increased
parallelism,
and
streamlined
command
set
Same
connector
as
the
2.5
SFF
SAS
HDDs/SSDs
(more
pin
out
used)
NVMe
drives
also
exist
in
other
form
factors
(e.g.
PCIe
and
M.2
cards)
Copyright
2015,
Oracle
and/or
its
aliates.
All
rights
reserved.
|
NVMe
Technology
Oered
with
SPARC
T7
and
M7
Servers
Internal
2.5
SFF
NVMe
Drives
in
SPARC
T7-1,
T7-2
and
T7-4
SPARC
T7-1:
Up
to
4
NVMe
SFF
Drives
(requires
one
PCIe
switch
card)
SPARC
T7-2:
Up
to
4
NVMe
SFF
Drives
(requires
one
or
two
PCIe
switch
card)
SPARC
T7-4:
Up
to
8
NVMe
SFF
Drives
(requires
two
PCIe
switch
cards)
Memory
PCIe
Gen3
PCIe
Root
Complex
PCIe
SAS
Controller
12
Gb/sec
SAS3
SAS3
to
Flash
Controller
Flash
Flash
Flash
Flash
Flash
Flash
Flash
Flash
Standard SSD
Memory
PCIe
Root
Complex
32
Gb/sec
PCIe
Gen3
PCIe
to
Flash
Controller
Flash
Flash
Flash
Flash
Flash
Flash
Flash
Flash
T7-1
NVMe
Cabling
One
NVMe
Switch
Card
Must
be
installed
in
Slot3
AC0
AC1
Rear
System
Indicators
4x 10GBASE-T
2x USB 3.0
PCIe 6
PCIe 5
SP Network 100BASE-T
PCIe 4
PCIe 2
SP Serial
PCIe 3
HD-15 VGA
PSU1
PCIe 1
PSU0
4x
Memory
DIMMs
SAS
HBA
IO
Controller
ASIC
SPARC
M7
Processor
CPU
Module
(CM)
Embedded
USB
(eUSB)
Fan
Module
Cover
4x
Dual-Fan
Modules
(Top
Loading)
Power
Supplies
(Rear
Access)
Memory
Riser
1
Copyright
2015,
Oracle
and/or
its
aliates.
All
rights
reserved.
|
Fans
System
will
con@nue
to
operate
with
fan
failure(s)
unless
an
over
temperature
occurs
System
will
power
on
with
one
failed
fan
in
any
of
the
fan
modules
System
will
not
power
on
with
a
missing
fan
module
Fan
Modules
Power
Supplies
2.5
SAS
HDDs/SSDs
2.5
NVMe
SSDs
Motherboard
Disk
Backplane
Cage
DVD
Drive
LED
Indicator
Modules
Memory
Riser
Memory
DIMMs
PCIe
Cards
Service
Processor
Module
(SPM)
System
Congura@on
PROM
System
Bakery
Embedded
USB
ash
memory
(eUSB)
Copyright
2015,
Oracle
and/or
its
aliates.
All
rights
reserved.
|
Feature
Form
Factor
Processor
Memory
Integrated
Network
Ports
Internal
Storage
Removable
Media
Management
Ports
USB
Ports
PCI
Express
Slots
Fans
Hot-Swappable
Power
Supplies
Maximum
Power
Consump@on
SPARC T7-2
SPARC T5-2
Power
Bukon
Status
LEDs
4x
NVMe
Capable
Drive
Bays
SAS5/NVMe3
SAS4/NVMe2
SAS3/NVMe1
SAS2/NVMe0
SAS1
SAS0
RFID/Serial
Number
2x
USB
2.0
Ports
HD-15
VGA
Port
DVD
AC0
AC1
Rear
System
Indicators
PCIe
5
4x
10GBASE-T
2x USB 3.0
PCIe 8
SP Network 100BASE-T
PCIe 7
SP Serial
PCIe 4
PCIe 3
PCIe 2
HD-15 VGA
PCIe 6
PSU1
PCIe 1
PSU0
2x IO Controller ASICs
6x
Fans
(Top
Loading)
Service
Processor
2x
Power
Supplies
(Rear
Access)
Example
1:
4x
32G
DIMMs
on
[Memory
Risers
0-0,
0-1,
0-2,
0-3]
+
4x
16G
DIMMs
on
[Memory
Risers
1-0,
1-1,
1-2,
1-3]
Example
2:
2x
32G
DIMMs
on
[Memory
Risers
0-0,
0-1,
0-2,
0-3]
+
4x
16G
DIMMs
on
[Memory
Risers
1-0,
1-1,
1-2,
1-3]
Fans
System
will
con@nue
to
operate
with
a
single
fan
failure
(any
1
of
the
6
failed)
unless
an
over
temperature
occurs
System
will
power
on
if
5
of
the
6
fan
modules
are
present
,
any
single
one
can
be
missing
Note that NVMe and SAS drive bay numbering are dierent
SPARC
T7-2
Server
-
NVMe
2.5
SFF
Drives
Device
Nomenclature
and
path
names
NVMe
Bay
Shared
One
PCIe
Switch
Card
(PCIe
Slot
1)
SAS
Bay
NVMe0
HDD2
/pci@306/pci@1/pci@0/pci@4/nvme@0/disk@1
NVMe1
HDD3
/pci@306/pci@1/pci@0/pci@5/nvme@0/disk@1
NVMe2
HDD4
/pci@306/pci@1/pci@0/pci@6/nvme@0/disk@1
NVMe3
HDD5
/pci@306/pci@1/pci@0/pci@7/nvme@0/disk@1
SAS5/NVMe3
SAS4/NVMe2
SAS3/NVMe1
SAS2/NVMe0
NVMe
Bay
Shared
Two
PCIe
Switch
Cards
(PCIe
Slots
1,2)
SAS
Bay
NVMe0
HDD2
/pci@306/pci@1/pci@0/pci@6/nvme@0/disk@1
NVMe1
HDD3
/pci@306/pci@1/pci@0/pci@7/nvme@0/disk@1
NVMe2
HDD4
/pci@307/pci@1/pci@0/pci@6/nvme@0/disk@1
NVMe3
HDD5
/pci@307/pci@1/pci@0/pci@7/nvme@0/disk@1
SAS1
SAS0
DIMM (BOB0/Channel0)
DIMM (BOB0/Channel1)
DIMM (BOB1/Channel0)
DIMM
(BOB1/Channel1)
BOB0
BOB1
Fan
Modules
Power
Supplies
2.5
SAS
HDDs/SSDs
2.5
NVMe
SSDs
Motherboard
Service
Processor
(SP)
Disk
Backplane
Cage
Power
Supply
Backplane
Fan
Board
Memory
Riser
Memory
DIMMs
PCIe
Cards
DVD
Drive
System
Congura@on
PROM
System
Bakery
Embedded
USB
ash
memory
(eUSB)
Copyright
2015,
Oracle
and/or
its
aliates.
All
rights
reserved.
|
Feature
Form
Factor
CPU
Memory
Integrated
Network
Ports
Internal
Storage
Removable
Media
Management
Ports
USB
Ports
PCI
Express
Slots
Fans
Hot-Swappable
Power
Supplies
Maximum
Power
Consump@on
SPARC T7-4
SPARC T5-4
Locator
LED/Bukon
Front
System
Indicators
Power
Bukon
Status
LEDs
SAS1/NVMe1
SAS3/NVMe3
SAS5/NVMe5
SAS7/NVMe7
HD-15 VGA
SAS0/NVMe0
SAS2/NVMe2
SAS4/NVMe4
SAS6/NVMe6
SP
Serial
2x
USB
2.0
RFID/Serial
Number
Power Supply 0
Power Supply 1
Power Supply 2
Power Supply 3
AC0
AC1
Rear
System
HD-15
VGA
4x
10GBASE-T
Indicators
SP
Serial
2x
USB
3.0
SP
Network
100BASE-T
Copyright
2015,
Oracle
and/or
its
aliates.
All
rights
reserved.
|
AC2
PCIe 16
PCIe 15
Fan Module 4
PCIe 14
PCIe 13
PCIe 12
PCIe 11
Fan Module 3
PCIe 10
PCIe 9
PCIe 8
Fan Module 2
PCIe 7
PCIe 6
PCIe 5
Fan Module 1
PCIe 4
PCIe 3
PCIe 2
PCIe 1
Fan Module 0
AC3
Ini@al
server
order
must
have
only
one
type
of
DIMMs,
either
half
or
fully
populated
Half-populated
-
16
DIMMs
per
Processor
Module
(PM),
1
DIMM
per
BoB
Fully-populated
-
32
DIMMs
per
PM
Memory
congura@on
on
one
PM0
can
be
dierent
from
PM1
via
X-Op@ons
Both
ATO
and
X-op@ons:
All
DIMMs
on
a
PM
must
be
of
same
type
and
capacity
Fans
Service
Processor
Module
(SPM)
SAS
Controller
(SAS1)
SPARC
M7
Processor
(CPU1
or
CPU3)
SPARC
M7
Processor
(CPU0
or
CPU2)
Fan
Modules
Power
Supplies
2.5
SAS
HDDs/SSDs
2.5
NVMe
SSDs
PCIe
Cards
in
the
carrier
Redundant,
hot-swap
cooling
fans
Hot
plug
I/O
adapters
(T7-4)
Redundant,
hot-swap
power
supplies
Copyright
2015,
Oracle
and/or
its
aliates.
All
rights
reserved.
|
Agenda
1
Systems Overview
T7-1
T7-2
T7-4
Feature
SPARC M7-8
SPARC T5-8
4x
10GBASE-T
Up
to
8
x
2.5
SAS
3.0
HDD
or
SSD,
hot-plug
via
rKVMS
Management Ports
-
Up
to
24x
PCIe
3.0
(x16)
slots
Hot-Plug
Low
Prole
slots
with
Card
Carrier
8
x
Redundant
Hot-Swap
Dual
Fan
Modules
6
x
3000
Wak
AC,
N+N
8,923
W
4x
USB
3.0
16x
PCIe
3.0
(x8)
slots
Hot-Plug
Low
Prole
slots
with
Card
Carrier
10
x
Redundant
Hot-Swap
Dual
Fan
Modules
4
x
3000
Wak
AC,
N+N
6,060
W
Form
Factor
Physical
Domains
Processor
Max.
Processors/Cores/Threads
Memory
USB
ports
PCI
Express
Slots
Fans
Redundant
Hot-Swap
Power
Supplies
Maximum
Power
Consump@on
CMIOU
Chassis
SPARC
M7-8
and
M7-16
Servers
Front
Fan
Modules
(8x)
Rear
Control
&
LEDs
Service
SP
Tray
Rear
Processors
(SP)
CMIOU (8x)
Front
Control
&
LEDs
10RU
CL/SL
Interconnect
Assemblies
(4x)
CL
Interconnect
Assembly,
wide
(1x)
SP
Interconnect
Assembly
(1x)
CMIOU
Board
SPARC
M7-8
and
M7-16
Servers
DIMM
Sockets
(8x2)
PCIe
3.0
(x16)
LP
Slot1
Card
Carrier
eUSB Device
SPARC
M7
Processor
SP
Truss
Connec@on
I/O
Controller
Coherency/Scalability
Link
Connec@ons
DC/DC Converters
DIMM
16
DIMM
16
M7
M7
M7
DIMM
16
M7
POINT-TO-POINT
LOCAL
INTERCONNECT
M7
Memory
Bandwidth
Per
M7
=
333GB/sec
Or
2.66
TB/sec
for
M7-8
DIMM
16
DIMM
16
M7
M7
DIMM
16
M7
DIMM
16
DIMM
16
CMIOU
0
CMIOU
1
CMIOU
2
CMIOU
3
CMIOU
4
CMIOU
5
CMIOU 6
eUSB x1
eUSB x1
eUSB x1
eUSB x1
eUSB x1
eUSB x1
eUSB x1
SP1/SPM0 x1
eUSB x1
SP0/SPM0 x1
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
CMIOU 7
DIMM
16
DIMM
16
Memory
Bandwidth
Per
M7
=
333GB/sec
or
1.3
TB/sec
(per
PDOM)
POINT-TO-POINT
LOCAL
INTERCONNECT
M7
M7
DIMM
16
DIMM
16
M7
M7
DIMM
16
M7
M7
POINT-TO-POINT
LOCAL
INTERCONNECT
M7
DIMM
16
DIMM
16
M7
DIMM
16
CMIOU
0
CMIOU
1
CMIOU
2
CMIOU
3
CMIOU
4
CMIOU
5
CMIOU
6
eUSB x1
eUSB x1
eUSB x1
SP1/SPM1 x1
eUSB x1
SP0/SPM1 x1
eUSB x1
eUSB x1
eUSB x1
SP1/SPM0 x1
eUSB x1
SP0/SPM0 x1
IOC
IOC
IOC
IOC
IOC
IOC
IOC
IOC
CMIOU 7
PDOM0
All
the
memory
on
the
CMIOU
must
be
the
same
density
and
type
Mixing
memory
in
DCUs
and
PDoms
is
supported
PDOM1
PDOM0
Feature
Form
Factor
Physical
Domains
Processor
Max.
Processors/Cores/Threads
Memory
Integrated
Network
Ports
Internal
Storage
Removable
Media
PCI
Express
Slots
Fans
Power
Connec@ons
Maximum
Power
Consump@on
SPARC M7-16
SPARC M6-32
Base
IO
Cards
Up
to
32
x
2.5
SAS
HDD
or
SSD,
hot-pluggable
via
rKVMS
64x
PCIe
3.0
(x8)
slots
Hot-Plug
Low
Prole
slots
with
Card
Carrier
10
x
Redundant
Hot-Swap
Dual
Fan
Modules
3-phase/Dual
Grid,
total
of
6
inputs
cables
26,490
W
CMIOU Chassis
Switch Chassis
DCU
1
DCU
0
DCU
Coherency Links
Scalability Links
DIMM
16
DIMM
16
M7
Bisec]on
Bandwidth:
218
GB/sec
4
x12
CL
links
x
27
GB/sec/link/direc]on
M7
LOCAL
INTERCONNECT
M7
Memory
Bandwidth
Per
M7
=
333
GB/sec
1.3
TB/sec
for
a
4-way
DCU
5.3
TB/sec
for
a
16-way
M7-16
DIMM
16
M7
DIMM
16
DCU1
DCU3
CMIOU
Chassis
#1
Scalability
ASICs
Switch
Chassis
CMIOU
Chassis
#0
DCU0
Copyright
2015,
Oracle
and/or
its
aliates.
All
rights
reserved.
|
DCU2
Scalability ASIC
SP
Internal
Interconnect
Connector
7
6
5
4
External
Interconnect
Connectors
(x8)
Scalability ASIC
3
2
1
SWU
Port
Number
Rear
Control
&
LEDs
Front
Rear
Dual
Service
Processors
Switch
Module
Fans
(36x)
External
Interconnect
Assemblies
(8x)
AC Inlets (4x)
CMIOU
0
CMIOU
1
CMIOU
2
CMIOU
3
CMIOU
4
CMIOU
5
CMIOU 6
CMIOU 10
eUSB x1
CMIOU 9
eUSB x1
DCU 0
M7
#8
M7
#9
M7
#10
M7
#11
M7
#12
M7
#13
M7
#14
M7
#15
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
CMIOU 11
DCU 1
M7
#0
M7
#1
M7
#2
M7
#3
M7
#4
M7
#5
M7
#6
M7
#7
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
CMIOU 7
PDOM 2
eUSB x1
eUSB x1
eUSB x1
SPP3/SPM1 x1
eUSB x1
SPP2/SPM1 x1
eUSB x1
eUSB x1
DCU 2
CMIOU 8
eUSB x1
SPP1/SPM1 x1
CMIOU 11
eUSB x1
SPP0/SPM1 x1
CMIOU 10
eUSB x1
CMIOU 9
eUSB x1
eUSB x1
SPP3/SPM0 x1
eUSB x1
SPP2/SPM0 x1
PDOM 1
CMIOU 8
eUSB x1
SPP1/SPM0 x1
eUSB x1
SPP0/SPM0 x1
PDOM 0
PDOM2
PDOM1
Minimum of one 4-way DCU (DCU0), or two 2-way DCUs (DCU0 and DCU2)
All
the
memory
on
the
CMIOU
must
be
the
same
density
and
type
Mixing
memory
in
DCUs
and
PDoms
is
supported
iSCSI (Ethernet)
iSCSI (Inniband)2
Connects
to
N/A
Embedded
USB
(eUSB)
and
Boot
over
Inniband
New
Oracle
Solaris
Boot
Process
Boot
archive
allows
root
le
system
mount
using
iSCSI
over
IPoIB
Fall
back:
A
boot
archive
exist
on
the
on
system
service
processor
Copyright
2015,
Oracle
and/or
its
aliates.
All
rights
reserved.
|
SP is responsible for:
SPARC
M7-8
with
1
PDom:
Dual
SPs
with
1
SPM
in
each
suppor@ng
one
PDom
SPARC
M7-8
with
2
PDoms:
Dual
SPs
with
2
SPMs
in
each
suppor@ng
two
PDoms
SPARC
M7-16:
Dual
SPMs
in
all
four
SPPs
in
the
CMIOU
chassis,
and
dual
SPs
in
the
switch
chassis
suppor@ng
up
to
4
PDoms
Copyright
2015,
Oracle
and/or
its
aliates.
All
rights
reserved.
|