0% found this document useful (0 votes)
361 views

EDM - Screen Shot For Profile Creation

This document outlines the steps to set up real-time pricing for electricity billing in SAP. It involves 1) creating a profile for quantities and prices, 2) setting up an RTP component and interface in SPRO, 3) creating master billing data like rates, schemas, and rate determination, 4) setting up register groups, materials, device categories and devices, 5) allocating profiles to devices, 6) defining profile quantity and price values, 7) creating meter reading orders, and 8) generating billing documents and invoices. The process covers both technical and master data configuration in different SAP modules.

Uploaded by

soumyajit1986
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
361 views

EDM - Screen Shot For Profile Creation

This document outlines the steps to set up real-time pricing for electricity billing in SAP. It involves 1) creating a profile for quantities and prices, 2) setting up an RTP component and interface in SPRO, 3) creating master billing data like rates, schemas, and rate determination, 4) setting up register groups, materials, device categories and devices, 5) allocating profiles to devices, 6) defining profile quantity and price values, 7) creating meter reading orders, and 8) generating billing documents and invoices. The process covers both technical and master data configuration in different SAP modules.

Uploaded by

soumyajit1986
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 20

1) Profile Header

Crate Profile T-code EEDM06 1. Quantity


Mandatory Field Profile Desc., Location of PVs, Profile type, Valid from, Interval Length, PV
category, Meas. Unit for MR, Currency.

Crate Profile T-code EEDM06 2. Price


Mandatory Field Profile Desc., Location of PVs, Profile type, Valid from, Interval Length, PV
category, Meas. Unit for MR, Currency.

Go to SPRO

2) Create RTP Component (SPRO Setting)


Mandatory Field Desc., Block Category, Block, then COPY, Click Generated Component
Code.

Define RTP Component

Define RTP Interface

3) Create RTP Interface (SPRO Setting)


Mandatory Field Formula Profile Calculation, Interval Length, Division, Day Offset, Result
number, Res.param.desc., Operand cat., Result function, then COPY, RTP Component
activation, On peak & Off Peak - Create Input Parameter, then COPY , Output Parameter, then
COPY.

4) Create Billing Master Data

Create Rate T-code EA30

Create Schema T-code EA35

Create Rate Category T-code EA53

Create Rate Type T-code EA56

Create Rate Determination T-code EA87

5) Create Register Group T-code EG04

6) Create Material T-code MM01


7) Create Device Category T-code EA01
8) Create Device T-code IQ01
9) Create Installation T-code ES30
10)

Full Installation T-code EG31

11)

Move-in T-code EC50E

12)

Profile Allocation T-code EEDMO4

Select Date click on Profile no. and Select Profile Allocation Role then assign Device

13)

Profile Values T-code EEDMO1

Define Quantity Value & Price Value

14)

Create Meter Reading Order - T-code EL01

15)

Create Billing Document T-code EASIBI

16)

Create Invoicing T-code EA19