Glassware Calibration-Conical Flasks

This document is an in-house calibration certificate for laboratory equipment. It summarizes the calibration of a piece of equipment performed on May 1, 2015 according to calibration procedures ASTM E542 & E1404. The calibration was performed by Nizam Uddin and approved by Gayan Priyankara using air temperature, air pressure, and glassware standards. Raw data is provided from the calibration including measurements taken and tolerances checked against specified values.

Uploaded by

Gayan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
148 views

Glassware Calibration-Conical Flasks

This document is an in-house calibration certificate for laboratory equipment. It summarizes the calibration of a piece of equipment performed on May 1, 2015 according to calibration procedures ASTM E542 & E1404. The calibration was performed by Nizam Uddin and approved by Gayan Priyankara using air temperature, air pressure, and glassware standards. Raw data is provided from the calibration including measurements taken and tolerances checked against specified values.

Uploaded by

Gayan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

IN-HOUSE CALIBRATION CERTIFICATE

Equipment Type

Certificate No.

Size

Performed By

Reference No.

Cal. Date

Manufacturer

Cal. Due Date

Calibration Procedure :
Standards Used to
Calibrate the
Equipment

Name
Ref. No.
Cal. Due Date

Calibration Performed By :

Approved By :

Nizam Uddin

Gayan Priyankara

QA/QC Engineer
Owner:Quality Management Representative
ERI-QR-07-01
Date: 01.05.2015

Page 1 of 1

Copy Rghts Reserved By ERI

RAW DATA
FOR ALL LABORATORY TEST AND IN-HOUSE CALIBRATION
Equipment Type

Certificate No.

Size

Performed By

Reference No.

Cal. Date

Manufacturer

Cal. Due Date

Calibration Procedure : ASTM E542 & E1404


Standards Used to
Calibrate the
Equipment

Air Temperature
Air Pressure

Name
Ref. No.
Cal. Due Date

C
mmHg

Glassware Material

Water Temperature

Relative Humidity

To Contain

Callibration Method

Class

To Deliver

Specified Values
Overall Height

mm

Body OD Widest Point

mm

Minimum Graduation

mL

Maximum Graduation Subdivision

mL

Nominal
Volume
(mL)

Initial
Loaded
Weight of Weight of
Trial No. Flask (g) Flask (g)
IE

IL- IE

V20
(mL)

Tolerance

Remarks

IL

Average

V20 = ( IL- IE) Z


Note :

Calibrated By:

Owner:Quality Management Representative

Page 1 of 1