Troubleshooting TRX FAULTY 7606

TRX 2, 4, and 6 on BTS 1321 are faulty. The document provides steps to troubleshoot the issue including resetting the individual TRXs, the entire BTS, and the whole site to try and resolve the faulty TRXs. Monitoring showed that resetting the TRXs and BTS did not resolve the issue, so resetting the entire site may be required as the next troubleshooting step. The document also provides commands for running loopback tests on individual TRXs to help diagnose issues.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
188 views

Troubleshooting TRX FAULTY 7606

TRX 2, 4, and 6 on BTS 1321 are faulty. The document provides steps to troubleshoot the issue including resetting the individual TRXs, the entire BTS, and the whole site to try and resolve the faulty TRXs. Monitoring showed that resetting the TRXs and BTS did not resolve the issue, so resetting the entire site may be required as the next troubleshooting step. The document also provides commands for running loopback tests on individual TRXs to help diagnose issues.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 10

7606: TRX FAULTY

TROUBLESHOOTING

UNDERSTANDING ALARM in BSC


BSC Name
BCF ID

Day/Timealarmreported
BTSID (cellid)

BTSNAME (cell name)

AlarmNumber

Alarmdescription

ConsecutiveNumber

ZEOL::NR=7606;

Displaying activealarm no7706for all BCF

ZEOL:109:NR=7606 Displaying activealarm no7706for BCF=109only


Displaying all active alarm for BCF=109 only
ZEOL:109::;
Displayingallactive alarm for all BCF
ZEOL;

UNDERSTANDING BCF CONGIGURATION


BSC nameis PTK_INNER9
BCF=132 BTS typeis FLEXI
MULTIRADIO
TRX 2, 4 & 6 are BL-TRX
ETPCM are ET=1084 and
ET=1097
Freq BCCHis 833
TRX-1 is BCCH
Site name is RASAUJAYAMD
BCF 132 havetwo BTS 1321
and 1322
Number TRX in BTS=1321is
6 TRXs, BTS=1322is 8 TRXs

RESET TRX
TRX reset can be donebyLOCKEDand UNLOCKEDTRX
ZERS:BTS=1321,TRX=2:L; LOCKED TRX-2 on BTS=1321

TRX2 on BTS 1321


Administration state is Locked
Operatopnal state is BL-USER

ZERS:BTS=1321,TRX=4&6:L;

LOCKED TRXno4 & 6 on BTS=1321

ZERS:BTS=1321,TRX=4&&6:L; LOCKED TRX no 4 until 6 (4,5,6) on BTS=1321

Changestate from LOCKED to UNLOCKwill resetingTRX


ZERS:BTS=1321,TRX=2:U;

UNLOCKEDTRX-2 inBTS=1321

After LOCK/UNLCOK TRX


2, 4 and 6, all TRXs
becomeWOat time
22:45:08 Well done
But keep monitoring

Monitoringat 22:48:38
TRX 2,4&6 back to FAULTY
Itmean RESETTRX not the
right solution for this case
For a right solution please
UHIHU WR Trouble
MDQDJHPHQW DRFXPHQW

RESET BTS
BTS reset canbe donebyLOCKED andUNLOCKED BTS
ZEQS:BTS=1321:L; LOCKED BTS 132 and all BTS 1321service immediatelyinterrupted
ZEQS:BTS=1321:U; UNLOCKED BTS 132 and allTRX on BTS 1321will reset

BTS 1321unlockedat 23:04:48


Monitoringuntil 23:26:18all TRX
Still WO.
Seem BTS RESETis a good solution
for this case
Ifproblem stillappear, please refer to
TURXEOH MDQDJHPHQW DRFXPHQW

RESET SITE
ZEFR:132:SITE; Reset BCF, allBTS and all TRX in BCF=132 will be reset and all
services is interruptedimmediatelyuntil TRXback to WO

TRX Loopback
Test
3 cmds go together

Runs Test
Prints test results
Deletes test report

Transciever Test
ZUBS:BTS=bts,TRX=trx;
ZUBP:TR:BTS=bts,TRX=trx;
ZUBD:TR:BTS=bts,TRX=trx;

ZUBS:BTS=1213,TRX=12:;

ZUBD:TR:BTS=1213,TRX=12:;

ZUBP:TR:BTS=1213,TRX=12:;

Thank You