Rectangular Concrete Beam/Column Analysis

This document provides the analysis results for a rectangular concrete beam-column with reinforcing bars. It includes the member dimensions, material properties, applied loads, reinforcing details, and calculated member capacities. Interactive diagrams show the relationships between axial load and bending moment capacities in both principal axes. Key results are the member's biaxial capacity under the given loads and the effective length criteria to qualify it as a "short column".

Uploaded by

Josh Claure
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views1 page

Rectangular Concrete Beam/Column Analysis

This document provides the analysis results for a rectangular concrete beam-column with reinforcing bars. It includes the member dimensions, material properties, applied loads, reinforcing details, and calculated member capacities. Interactive diagrams show the relationships between axial load and bending moment capacities in both principal axes. Key results are the member's biaxial capacity under the given loads and the effective length criteria to qualify it as a "short column".

Uploaded by

Josh Claure
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

"RECTBEAM (318-05).

xls" Program
Version 1.1

RECTANGULAR CONCRETE BEAM/COLUMN ANALYSIS

Y-AXIS INTERACTION DIAGRAM

X-AXIS INTERACTION DIAGRAM


350

350

300

300

Input Data:

250

250

200

200

150

150

X
Nsb=2

Ly=9.84

Ntb=6

Pnx (k)

Reinforcing Yield Strength, fy =


60
ksi.
Concrete Comp. Strength, f 'c =
2.988
ksi
Total Member Width, Lx =
9.840
in.
Total Member Depth, Ly =
9.840
in.
Distance to Long. Reinforcing, d' =
1.000
in.
Ultimate Design Axial Load, Pu =
90.37
kips
Ultimate Design Moment, Mux =
2.39
ft-kips
Ultimate Design Moment, Muy =
0.33
ft-kips
Total Top/Bot. Long. Bars, Ntb =
6
Top/Bot. Longitudinal Bar Size =
4
Total Side Long. Bars, Nsb =
2
Side Longitudinal Bar Size =
3
Results:
Gross reinforcing ratio provided:
g = 0.01467

Lx=9.84
Y

Pny (k)

For Biaxial Flexure with Axial Compression or Tension Load


Assuming "Short", Non-Slender Member with Symmetric Reinforcing (per ACI 318-05 Code)
Job Name: UNIDAD EDUCATIVA SICAYA
Subject:
Job Number: Diseo Columna Tipo 2 (P Alta) 25X25 cm.
Originator: JCS
Checker:

100

50

100

50

d'=1 (typ.)
0

0
0

Member Section

10

20

30

40

50

60

-50

-100

10

20

30

40

50

60

-50

Mnx (ft-k)

-100

Mny (ft-k)

X-axis Flexure and Axial Load Interaction Diagram Points


ey (in.)
Comments
Location Pnx (k) Mnx (ft-k)
Point #1
212.88
0.00
0.00
Nom. max. compression = Po
Point #2
170.31
0.00
0.00
Allowable Pn(max) = 0.8*Po
Point #3
170.31
13.01
0.92
Min. eccentricity
0% rebar tension = 0 ksi
Point #4
149.59
19.35
1.55
25% rebar tension = 15 ksi
Point #5
125.09
24.23
2.32
50% rebar tension = 30 ksi
Point #6
105.12
27.47
3.14
100% rebar tension = 60 ksi
Point #7
72.80
31.30
5.16
Point #8
28.93
26.93
11.17
Pn = 0.1*f'c*Ag
(Infinity )
Point #9
0.00
24.04
Pure moment capacity
Point #10
-76.68
0.00
0.00
Pure axial tension capacity

Y-axis Flexure and Axial Load Interaction Diagram Points


ex (in.)
Location Pny (k) Mny (ft-k)
Comments
Point #1
212.88
0.00
0.00
Nom. max. compression = Po
Point #2
170.31
0.00
0.00
Allowable Pn(max) = 0.8*Po
Point #3
170.31
12.40
0.87
Min. eccentricity
0% rebar tension = 0 ksi
Point #4
150.41
18.19
1.45
25% rebar tension = 15 ksi
Point #5
125.81
22.79
2.17
50% rebar tension = 30 ksi
Point #6
105.85
25.75
2.92
100% rebar tension = 60 ksi
Point #7
73.40
29.01
4.74
Point #8
28.93
25.04
10.39
Pn = 0.1*f'c*Ag
(Infinity )
Point #9
0.00
22.46
Pure moment capacity
Point #10
-76.68
0.00
0.00
Pure axial tension capacity

Member Uniaxial Capacity at Design Eccentricity, ey:


Interpolated Results from Above:
ey (in.)
Pnx (k) Mnx (ft-k)
170.31
13.01
0.32

Member Uniaxial Capacity at Design Eccentricity, ex:


Interpolated Results from Above:
ex (in.)
Pny (k) Mny (ft-k)
170.31
12.40
0.04

Biaxial Capacity and Stress Ratio for Pu >= 0.1*f'c*Ag:


Pn = 141.92 kips Pn = 1/(1/Pnx + 1/Pny -1/Po) <= 1.0
S.R. = Pu/Pn <= 1.0
S.R. =
0.637

Effective Length Criteria for "Short" Column:


k*Lu <=
5.41
ft. (for k*Lu/r(min) <= 22)
k*Lu <=
9.84
ft. (for k*Lu/r(min) <= 40)

Biaxial Stress Ratio for Pu < 0.1*f'c*Ag:


S.R. = (Mux/Mnx)^1.15 + (Muy/Mny)^1.15 <= 1.0
S.R. =
N.A.

Pure Axial Compression Capacity w/o Reinf.:


Pn = 127.88 kips Pn = 0.80*0.70*(0.85*f'c*Ag)

Tie Min. Size & Max. Spac.:


#3@6''

Columna Tipo 2 (planta alta) de 25x25 cm. con 4 12 + 4 10


Estribos 6 c/10/15