If SD Drop Is High PLZ Look On Parameters Like
If SD Drop Is High PLZ Look On Parameters Like
Overshooting
Shift the SD time slot
Hardware issue-Check Alarms.,TRX condition.,Check Path
Imbalance.,VSWR of the Cell.,Connector Connection.
Some times you will find issues on BCCH TRX.In this case BCCH shift
from one to other TRX will reduce SD drop.
Interference: Check the BCCH Plan (C/I or C/A). Co-BSIC & Co
BCCH. Change the values of RXP PMAX
It may be uplink or downlink issue in which cells for UL put a TMA in
that cell and for DL provide tilt
Re orient that antenna.
Use latest ND 111 and MapInfo to find out proper frequency to
reduce interference
High LAPD Utilization:Check LAPD util report from OSS, and define
32 kbps signaling instead of 16kbps