Purlin Design: Purlin Quickpick V21 8/9/2014... 8:29 AM 1 2

This document summarizes the design of a C15024 purlin with a 1 meter spacing and 3 meter span used in a roof with a 4 degree pitch. Loads including dead, live, and wind loads were calculated. The purlin's geometry, material properties, design actions and checks were analyzed. Ultimate moment and shear loads were found to be below capacity. Deflection due to live and dead loads was calculated to be within allowable limits. The purlin design was determined to meet requirements according to design standard BS 5950.

Uploaded by

Win Than
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
82 views

Purlin Design: Purlin Quickpick V21 8/9/2014... 8:29 AM 1 2

This document summarizes the design of a C15024 purlin with a 1 meter spacing and 3 meter span used in a roof with a 4 degree pitch. Loads including dead, live, and wind loads were calculated. The purlin's geometry, material properties, design actions and checks were analyzed. Ultimate moment and shear loads were found to be below capacity. Deflection due to live and dead loads was calculated to be within allowable limits. The purlin design was determined to meet requirements according to design standard BS 5950.

Uploaded by

Win Than
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Project Title:

PURLIN GEOMETRY
Purlin type C15024
Purlin spacing (m) 1.00
Purlin Span (m) 3.00
Roof pitch (Degree) 4.00
No. of tie rod or bridging 1.00
Building height (m) 15.00
Connection method D DOUBLE SPAN
DESIGN LOAD
Dead load (kN/m2) 0.25
Live load (kN/m2) 0.50
Wind load (kN/m2) 0.49
Yield strength of steel Fy (MPa) 450
DESIGN RESULT SUMMARY
Moment
Moment ratio due to ultimate load
= Wux/Wcx+Wuy/Wcy 0.10 <1.00 O.K.!
Moment ratio due to ultimate load with wind suction
= Wuw/Wcx+Wuy/Wcy 0.04 <1.00 O.K.!
Shear (kN) 4.60
Use 2 Nos. of M12 Bolt & Nuts Gr 4.6 O.K.!
Deflection
Deflection due to live + dead load (unfactored), mm 0.69 <L/150 Limit, O.K.!
Deflection due to deal load alone (unfactored), mm 0.26 <L/150 Limit, O.K.!
OVERALL CHECK
SECTION PROPERTIES OF PURLIN
Ixx ( x 106 mm4) 2.43
Iyy ( x 104 mm4) 0.39
Zxx ( x 103 mm3) 33.50
Zyy ( x 103 mm3) 8.78
Self weight (kg/m) 5.88
Moment capacity Mcx (kN.m) 15.08
Moment capacity Mcy (kN.m) 3.95
DESIGN ACTION
Total dead load Wd (kN) 0.92
In x-x axis Wdx (kN) 0.92
In y-y axis Wdy (kN) 0.06
Total live load Wl (kN) 1.50
In x-x axis Wlx (kN) 1.50
In y-y axis Wly (kN) 0.10
Total wind load Wwx (kN) 1.47
ULTIMATE LOAD
Ultimate load in x-x axis Wux (kN) 3.68
Ultimate load in y-y axis Wuy (kN) 0.26
Ultimate load with wind suction Wuw (kN) -1.14
MAXIMUM MOMENT
Due to ultimate load, in x-x axis Mux (kN.m) 1.38
Due to ultimate load, in y-y axis Muy (kN.m) 0.05
Due to wind suction, in x-x axis Muw (kN.m) -0.43
PURLIN DESIGN
PURLIN QUICKPICK V21 8/9/2014...8:29 AM 1 of 2
MAXIMUM SHEAR (kN)
Verical shear at supports (kN) 4.60
MAXIMUM DEFLECTION
Deflection due to live + dead load (unfactored), mm 0.69
Deflection due to deal load alone (unfactored), mm 0.26
DESIGN CHECK
Moment BS 5950
Moment ratio due to ultimate load
Mux/Mcx+Muy/Mcy = 0.10 <1.00 O.K.! Clause 1:4.8.2
Moment ratio due to ultimate load with wind suction
Muw/Mcx+Muy/Mcy = 0.04 <1.00 O.K.! Clause 1:4.8.2
Shear (kN) 4.60
Use 2 Nos. of M12 Bolt & Nuts Grade 4.6 at purlin end O.K.!
Deflection
Limit L/150 due to live & dead load, mm 20.00
Limit L/250 due to dead load alone, mm 12.00
Deflection due to live + dead load (unfactored), mm 0.69 <L/150 Limit, O.K.! Clause 1:4.12.2
Deflection due to deal load alone (unfactored), mm 0.26 <L/150 Limit, O.K.! Table 5