InstruCalc Control Valve Sizing03

This document summarizes the calculation of the required control valve size for a 6-inch globe valve used on a 6-inch inlet and outlet pipe to control oil flow for the HP DRY/WET SEPERATOR #1 tag number GC01-502C. It provides input data on flow rates, pressures, temperatures, and fluid properties. The output data calculates the required Cv, percent valve lift, cavitation index, and noise levels needed at minimum, normal, and maximum flow rates while ensuring no cavitation or flashing occurs. The valve size is selected based on a Masoneilan Model 25100 meeting the calculated requirements.

Uploaded by

Dinesh Kumar
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
266 views

InstruCalc Control Valve Sizing03

This document summarizes the calculation of the required control valve size for a 6-inch globe valve used on a 6-inch inlet and outlet pipe to control oil flow for the HP DRY/WET SEPERATOR #1 tag number GC01-502C. It provides input data on flow rates, pressures, temperatures, and fluid properties. The output data calculates the required Cv, percent valve lift, cavitation index, and noise levels needed at minimum, normal, and maximum flow rates while ensuring no cavitation or flashing occurs. The valve size is selected based on a Masoneilan Model 25100 meeting the calculated requirements.

Uploaded by

Dinesh Kumar
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

04/01/06

Ver.8.1.9. Control Valve Liquid Program - Calculate Valve Size


GC 01 - HP DRY/WET SEPERATOR # 1
Project . LCV REPLACEMENT .
Tag number GC01- 502C
Input Data
Valve
Data : 6 in Globe : Linear contour. Ports : One. Flow to : Close
Rated Cv : 76. Style Fd : 1
Pipe Sizes
Inlet : 6 in. Outlet : 6 in. Outlet pipe wall : 0.315 in
Fluid Data
Name : oil
Maximum Normal Minimum Units
Percent of nominal flow 150 50 36.11
Liquid flow 27000 9000 6500 bbl/d
Pressure drop 215 215 215 psi
Flow temperature 100 100 100 degF
Inlet pressure 280 280 280 psig
Vapor pressure 23.5 23.5 23.5 psia
Critical pressure 2500 2500 2500 psia
Viscosity @ FTP 11.5 11.5 11.5 cs
Specific gravity @ FTP .87 .87 0.87
Rated FL 0.94 0.94 0.94
Output Data
Required Cv 50.09 16.7 12.06 psi
Percent of valve lift 66 22 16
Cavitation index 1.2614 1.2614 1.2614
Noise level 84 79 77 dbA
Flow status Normal Normal Normal
Cavitation or Flashing None None None
Calculated FL .94 .94 .94
Sizing pressure drop 215 215 215 psi
Modified Volume English, data for all calculations, calculate size
Source - ANSI/ISA-75.01.01-2007 Flow Equations for sizing control valves
InstruCalc Ver.8.1.9.
Selection based on Masoneilan or equal Model 25100
Notes

You might also like