Api 610
Api 610
LOAD CASE
Location
Suction END
Discharge TOP
PUMP GEOMETRY
Size
x
6
0
4
0
Location
Suction END
Discharge TOP
Size
6
4
y
0
0
z
0
0
Mx
2300
1330
Moment (Nm)
My
Mz
1180
1760
680
1000
Location
Suction END
Discharge TOP
FRCA = [FXCA2+FYCA2+FZCA2]0.5
Where FXCA = FXSA + FXDA
FXCA =
Mz
0
0
MRCA = [MXCA2+MYCA2+MZCA2]0.5
Where MXCA = MXSA + MXDA - [(FYSA)(zS) + (FYDA)(zD) - (FZSA)(yS) - (FZDA)(yD)]/1000
MXCA = 0 + 0 - [(0)(0) + (0)(0) - (0)(0) - (0)(0)]/1000
0+0
FXCA =
Moment
My
0
0
MXCA =
FYCA =
0+0
FYCA =
MYCA =
FZCA =
FZCA =
FRCA
0+0
0
0
MZCA =
MRCA
0
0
Condition Equation
[FRSA / (1.5 x FRST4)] + [MRSA / (1.5 x MRST4)] <= 2
F-1
[ 0 / (1.5 x 4480)] + [0 / (1.5 x 3130)] <= 2
[FRDA / (1.5 x FRDT4)] + [MRDA / (1.5 x MRDT4)] <= 2
F-2
[ 0 / (1.5 x 2560)] + [0 / (1.5 x 1800)] <= 2
FRCA < 1.5 (FRST4 + FRDT4)
F-3
0 < 1.5 (4480 + 2560)
|MYCA| < 2.0 (MYST4 + MYDT4)
F-4
||0|| < 2.0 ((1180 + 680))
M
F-5
RCA < 1.5 (MRST4 + MRDT4)
0 < 1.5 (3130 + 1800)
Value
0
Limit Result
2 OK
2 OK
10560 OK
3720 OK
7395 OK
MR
3130
1800
MR
MR
0
0
MR
0
0