0% found this document useful (0 votes)
85 views

Sewer Net

This document provides information on designing sanitary sewer systems, including: - Key components like service connections, manholes, and pump stations - Design flows based on population density and infiltration rates - Hydraulic equations to calculate flow velocities and pipe sizing - Material types for rigid and flexible sewer pipes - Considerations for manholes and sulfide generation potential - An example problem outlining the design process for a trunk sewer system

Uploaded by

supriya2009
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views

Sewer Net

This document provides information on designing sanitary sewer systems, including: - Key components like service connections, manholes, and pump stations - Design flows based on population density and infiltration rates - Hydraulic equations to calculate flow velocities and pipe sizing - Material types for rigid and flexible sewer pipes - Considerations for manholes and sulfide generation potential - An example problem outlining the design process for a trunk sewer system

Uploaded by

supriya2009
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

CIVL 5346 Water Resources Engineering

Design of Sanitary Sewer System


Key components Service connections, Manholes and pump stations Design Flows 1. Infiltration and interflow (71 to 140 m3/d/km) 2. Flow from the service connections Type of Area Density (persons/ha) Large lots 5-7 Small lots, single family 75 Small lots, two family 125 Multistory apartments 2500 Design period: usually of the order of 50 years Variation in flow

Q peak Qave

5.5 ( P / 1000) 0.18

Qmin = 0.2( P / 1000) 0.16 Qave

P= population of the service area

Example: You are required to estimate the peak and minimum sewage flows for a town
having an area of 2500 ha. The residential area is 60% of the total area, whereas commercial and industrial areas are 30% and 10% of the total area, respectively. Of the residential area, 40% are large lots, 55% small single-family lots and 5% multistory apartments. The wastewater from the residential area is estimated to be 800 Lpcd. The sewage from commercial and industrial areas is estimated to be 25000 L/ha/d and 40000 L/ha/d, respectively. Type Large lots Small single family lots Multistory apartments Total Area(ha) 0.4(1500)= 600 0.55(1500) = 825 0.05(1500) = 75 Density (persons/ha) 6 75 2500 Population 3,600 61,875 187,500 252,975 Flow (m3/s) 0.03 0.57 1.74 2.34

CIVL 5346 Water Resources Engineering

Commercial sector = 30% of 2500 ha = 750 ha Average flow from commercial sector = 750x25,000 L/d= 0.22 m3/s Industrial sector = 10 % of 2500 ha = 250 ha Average flow from industrial sector = 250x40,000 L/d = 0.12 m3/s Thus, Average wastewater flow (excluding I/I) = 2.34+0.22+0.12 = 2.68 m3/s Assuming total population is equal to residential population, i.e. P= 252,975 Then,

Q peak Qave

5.5 5.5 = = 2.0 0.18 0.18 ( P / 1000) (252.975)

Qmin = 0.2( P / 1000) 0.16 = 0.2(252.975) 0.16 = 0.48 Qave


Hence, Peak flow = Peak factor x wastewater + I/I = 2.0(2.68)+0.03= 5.39 m3/s Minimum flow = 0.48(2.68) + 0.03 = 1.32 m3/s

Hydraulics of Sewers Minimum velocity (self-cleansing velocity) = 0.6 m/s Maximum velocity = 3.5 m/s Minimum pipe diameter = 150 mm. Sanitary sewers up to 375 mm diameter should be designed to run half full. Larger pipes may run three-fourths full.

CIVL 5346 Water Resources Engineering

The design problem Given: 1. Discharge, Q 2. Pipe Diameter, D 3. Pipe slope, S0 Determine: 1. Depth of flow, h 2. Minimum velocity, Vmin 3. Maximum velocity, Vmax

h=

D 1 cos 2 2
2/3 1/ 2 S0

sin A = D2 8

P=

D 2

A A Q= n P

Combining these equations we get

( sin )5 / 3 20.16nQ = 0
2/3
1/ 2 D8 / 3 S0

After solving it by trials we can compute A and then, V =

Q A

If

V < Vmin , reduce the diameter to achieve V Vmin

If diameter is the minimum (150 mm), put from the Mannings equation.

V = Vmin and find the slope of the pipe

CIVL 5346 Water Resources Engineering

Example: Determine the average velocity in a trunk sewer made of concrete (n=0.015)
having 1500 mm diameter laid on a slope of 1%. The peak discharge through the pipe is estimated to be 4000L/s. Given:

3 n = 0.015 , Q = 4m / s , S0 = 0.01 , D = 1.5m

( sin )5 / 3 20.16(0.015)(4) = 0
2/3
(1.5) 8 / 3 (0.01)1 / 2
By trials,

= 3.5radian
Therefore,

CIVL 5346 Water Resources Engineering

h=

D 3.5 1.5 1 cos 1 cos = = 0.88m 2 2 2 2

sin 2 3.5 sin 3.5 2 A = D2 = 1 . 5 = 1 . 08 m 8 8


The average flow velocity in the sewer is given by

V=

Q 4 = = 3.7m / s A 1.08

Sewer Pipe Material Rigid Pipes: Concrete, Cast iron, Vitrified clay Flexible pipes: Ductile iron, Steel, PVC Advantages and disadvantages of each category

Typical Manholes

CIVL 5346 Water Resources Engineering

Sulfide Generation

EBOD P Z = 0.308 0.5 0.33 B S0 Q

EBOD = BOD 1.07T 20 BOD = 5-day biochemical oxygen demand S 0 = Slope of the pipe Q = Discharge through the pipe P, B = Wetted perimeter and top width of the flow, respectively.
Z values Z < 5,000 5,000< Z < 10,000 Z > 10,000 Sulfide Condition Sulfide rarely generated Marginal condition for sulfide generation Sulfide generation common

Example: Check the potential for sulfide generation in the trunk sewer of the previous example, if 5-day BOD of the sewage is measured as 1600 mg/L and the ambient temperature in the sewer is 30oC. Solution:

EBOD = BOD 1.07T 20 = 1600 1.0710 = 3147.44


P= D 1.5 3.5 = = 2.625m 2 2 D 1.5 3.5 B = sin = sin = 0.738m 2 2 2 2
EBOD P 3147.44 2.625 = 0 . 308 0.5 0.33 0.5 0.33 S0 Q B 0.01 4 0.738

Z = 0.308

= 21822 > 10000


So, sulfide generation will be common in the sewer.

CIVL 5346 Water Resources Engineering

Design Computations

CIVL 5346 Water Resources Engineering

Example A sewer system is to be designed to service the area shown in the following Figure. The average per capita wastewater flow-rate is estimated to be 320 L/d/person, and the infiltration and inflow (I/I) is estimated to be 70 m3/d/km. The sewer system is to join an existing main sewer at manhole MH 5, where the average wastewater flow is 0.37 m3 /s, representing the contribution of approximately 100,000 people. The I/I contribution to the flow in the main sewer at MH 5 is negligible, and the main sewer at MH 5 is 1,065 mm in diameter, has an invert elevation of 55.35 m, and is laid on a slope of 0.9%. The layout of the sewer system shown in the figure is based on the topography of the area, and the pipe lengths, contributing areas, and ground-surface elevations are shown in the table. Design the sewer system between A Street and C Street for a saturation density of 150 persons/ha. Municipal guidelines require that the sewer pipes have a minimum cover of 2 m, a minimum slope of 0.08%, a peak flow factor of 3.0, a minimum flow factor of 0.5, and a minimum allowable pipe diameter of 150 mm.

CIVL 5346 Water Resources Engineering

CIVL 5346 Water Resources Engineering

Tutorial Problem (a) Use MS-Excel to design the sewerage system for Streets A and B shown in the previous example. (b) Use SewerCAD to design the sewerage system for Streets A and B shown in the previous example. Reference: Water Resources Engineering by Chin, 2000.

10