Modulex3
Line
GRID
Modulex3 Line
90U - 90f - 25 25
Complementary Products
CODE IRMA2 REMI R3IPT DESCRIPTION Interface Program for local PC to Modulex3 or R3IPT connection Interface Program for remote PC to Modulex3 or R3IPT connection Integrated Protection & Control for two/three winding transformers in 19, 3U Rack NUMERICAL CODE
Modulex3 Line
The system thus made, consists of the following unit: protection, measuring, control and monitoring modules, measurements module (I, V, P, Q, S, cos, f, Wh, VARh), I/O module (14 digital inputs, 5 digital outputs), allows protection, measurement, monitoring and control functions to be integrated without losing any of the characteristics of functional autonomy, which results into a better flexibility and availability of the system. Each component making up the Modulex3 line is in fact provided with dedicated CPU, memory, power supply unit, measuring, monitoring and control sections, communication line and HumanMachine Interface.
This means it may operate in standalone mode, independently from the condition of any other module possibly connected. The loss of a module does not involve the loss of all the provided functions. This is what would normally occur on a higher level of integration. Besides improved system availability during operation, this feature also offers a better flexibility in design and the possibility of further expanding the system, along with the associated functions, at later stages. Each module also features expanded self-monitoring functions with fault indications both local, on relay output and via field-bus. Versions using Modbus communication protocol are also available.
Modulex3 Line
The Protections
The Modulex3 line provides the user with a wide range of protections for electrical networks and equipment. The protection modules enable the monitored quantities to be measured and the maximum values to be stored. All the modules are equipped with local HMI allowing the unit programming and providing for a safe and guided access to all present and stored data. The protection modules also provide a fault recording function which enables the user to later analyze the monitored values in the event of an occurring fault. These data are made available to the user both through the serial interface located on the front side of the module, and by the bus card, if provided.
In current relays, the module also provide for CB's pole wear monitoring, which enable the user to evaluate the service condition of the electrical parts for the purpose of any routine maintenance schedule to be drawn up. It is furthermore possible to realise the trip circuit supervision. The modular character as well as the operating autonomy of each module allow conventional protection schemes to be set up. However, the use of the communication function makes it possible to also create logic selectivity schemes (one-time protection schemes), dramatically reducing the fault selection times.
The Measurements
This new group of products incorporates a measuring module which enables the user to access the following information, calculated or monitored: three-phase and zero sequence current, three-phase voltage, active power, reactive power, apparent power, frequenc, cos (power factor), bi-directional, active energy, bi-directional, reactive energy. These values can be locally read through the HMI located on the modules front side or through a local Personal Computer connected; in presence of the Local Area Network, they can also be viewed from an eventually installed remote intelligent unit (SCADA or Supervisor). With regard to input and output active and reactive power measurements, the module can also render these data available through pulse outputs. The measurement module can also be used as slave of a separate protection to extend the measurement and recording ranges.
Modulex3 Line
The use of a local or remote personal computer enables the user to make fault analysis by reading the disturbance recording stored by the measuring module. By using the information, whether directly derived from any VTs and CTs possibly present within the plant or calculated by the
measuring module, the user is in a position to monitor any burden and power values possibly involved. These data can then be stored, printed and/or used any time to evaluate the possible disconnection of non priority utilities or for network re-configuration.
More in detail, the following data are available: 14 Digital Inputs, 5 Relay Digital Outputs. The module allows states and/or alarms to be monitored, drives to be actuated, logical functions to be set up (e.g.: breaker and disconnector interlock).
Modulex3 Line
Configuration
All handled data are made available to the user on an engineering unit to be connected, by means of the RS232 serial interface. By means of the special software package supplied (IRMA2), the PC enables the user to access all present and stored data available in the unit (RCE), including disturbance recording data. The use of a Personal Computer, besides allowing for filing records and locally changing settings, also makes it possible to edit all settings beforehand, with PC off-line, and load them at a later stage, when the PC is on-line with the modules.
The information thus retrieved is made available to the user in the form of alarm, event lists, listings, measurement trends and charts of the monitored power systems. Moreover, the user can control any object among those displayed on the screen. The retrieved information can be used to locate any operating failure showing up within the plant and to implement customised functions aimed at scheduling any routine maintenance work to be carried out on the systems. The supervision system, available in the single and redundant versions, with or without front-end, allows for creating any Client/Server structure. Therefore, the supervision system is the natural complement of the Modulex3 line for a global solution involving distributed intelligence, aimed at the protection, monitoring and control of power systems.
Local HMI
All handled data are made available to the user through the display unit and the keyboard which are mounted on each module. More in detail, the following data are available: measurements (when currents are measured also the effective value of circuit-breaker pole wear (by I2t) is made available), configuration and setting parameters for current protections and automatic mechanisms, fault data. Through this interface the unit can be programmed and tested and even used to send manual controls.
SETTING MENU
The Supervision
The use of a real Supervision, Control and Data Acquisition system, known as SCADA, connected via fieldbus to the Modulex3 units, allows for a complete management of the power network. This ensemble performs the continuous monitoring of the network in terms of measurements, alarms and states and it performs also the network remote-control.
SETTING GROUP IN USE MAIN SETTING CHANGE SPARE SETTING CHANGE OUTPUT RELAYS DIGITAL INPUTS LED RELAY DATA LCD I> I> tstart t1 type ON 0.55 In 0.00 s CURVE C
RESET
RESET
Modulex3 Line
No. 6 output relays (1 for diagnostics, 5 are freely assignable) provided with goldon-silver contacts, all suitable for control and signalling functions (In 5A, Un 250V, 105 operations @ 0.3A, 110Vd.c., L/R=40ms): - output relays to be set as follows: normally deenergized or energised, selfor hand-reset, with adjustable min. pulse width.
Block I> Block I>> Block I>>> Block Io> Block Io>> Block Io>>> ... RESET
No. 3 or 5 digital inputs (protection and measuring modules), No. 14 digital inputs (I/O modules MX3MUX type), which can be set to implement the following functions: - settings groups dynamic switch (protection modules only), - threshold block (logic selectivity schemes with double backup protection), - remote reset, - auxiliary timer control, - LED control, - output relay control.
I> START I> TRIP I>> START I>> TRIP I>>> START I>>> TRIP
IN_DIG1
IN_DIG2
IN_DIG3
IN_DIG4
IN_DIG5
... ...
Optoinsulated inputs can be set to block, command and reset functions. Each input can be programmed as active high or active low
L1
L2
L3
L4
L5
L6
L7
L8
X1
X2
X3
X4
X5
No. 12 LEDs, 8 of which are freely assignable (starts, trips, self- or hand-reset settings). Protection functions: see dedicated Data sheets and catalogues. Two groups of settings or parameters (protection modules only): MAIN / SPARE. Threshold starting (alarm) outputs delayable by: 0-9.99 s.
Modulex3 Line
For overcurrent relays only: - First phase threshold and first ground fault threshold with dependent or independent time characteristic (A, B, C curves with extended ranges), with optional trip suspension of dependent time operation" when the second or third threshold starts (to avoid troubling selectivity).
t
t2
Trip suspension of dependent time operation when second or third threshold starts. This avoids any kind of interference between curves and characteristics of second and third thresholds.
Breaker failure function, delay: 0.02-1.00 s. Complete self-diagnosis, both during start up and while running. Possibility of TEST (LED and display or each single output relay or for each output relays and therefore to the connected network section). RTC for date and time, which can be synchronised via field-bus; operation without auxiliary power supply guaranteed for at least 7 days; no maintenance needed (no battery inside the module). Settings handled via front keyboard and display, local PC or field-bus. Large front display (LCD, backlighted, 2 lines of 16 characters each). Tree menu based Human Machine Interface, for an easy access to the reading and setting activities.
Multilingual menu (selections: English, French, Italian, Spanish). Some relays are also available in a special Central Europe version (English, French, German, Russian, multilingual menu). Serial interface with local PC (via front plug, fiber optic connection), with PC and/or supervision system (via rear serial Modbus connection port), for: - settings uploading and downloading, - settings groups dynamic switch (protection modules only), - measurements, - reading and resetting of partial counters, max. measurements and I2t, - fault recording, - event recording, - disturbance recording and fault-analysis, - synchronisation (via fieldbus), - controls (via field-bus), - Diagnostics. PC interface programs for local connection (IRMA2) and for remote connection (REMI).
Modulex3 Line
Standards
The Modulex3 line complies with EU directives: - LV 2006/95/CE - EMC 2004/108/CE
- UNIPEDE Norm (Spec) 13 "Automation and Control Apparatus for Generating Station and Sub-Station".
- ENEL R EMC02 - Norme CEI, CENELEC and IEC, standards for protection relays.
A C
(R) (L1)
A
(S)
(L2)
B (T)
(L3)
C
/+ /-
Output relay s 21 20 25 23
B
P1 S1 P1 S1
1 2 3 4 IB IC IA
X1 X2
22 24 27
P1 S1 P1 S1
5 6
X4 X5
X3
26 28 30 29 31 35 33
7 8 IO X6
X3 X4 X5
Uo: 270-0-90)
9 10 UO X4
34 32 37 38 36 40 39 41
CH
AP
+ +
X5
177 mm
104 mm
X6
X52
+ + + -
44 43 45
P1 S1 P1 S1 P1 S1
1
2 3 4 5 6
154 mm
42
LEDs
216 mm
PC interfac e 0V # +5V Rx
27 mm
7 8
L5 L6 L7 L8
10
98 mm
Tx
Dimensions
Modulex3 Line
11
Modulex3 Line
ALSTOM TRACK RECORD MODULEX3 LINE PRESENTATION OF LINE MX3AM IN 1995 PRESENTATION OF LINE MX3IPG FOR GENERATORS IN 1992 PRESENTATION OF LINE MX3EG FOR AUTOMATIC PARALLEL AND SYNCHRONISM CHECK IN 2005 PRESENTATION OF LINE MX3DK5600, DK5740 INTERFACE PROTECTION IN 2005 PRESENTATION OF LINE MX3CEI016, NEW INTERFACE PROTOCOL IN 2009 LINE MX3 1995-2010, MORE THAN 30000 UNITS SOLD IN THE WORLD