PROJECT JOB TITLE. JOB NO. SHEET NO.
TESFFA-96 BEAM DESIGN
DATE August 22,2006 DES. BY Elias.W CHECKED BY CLIENT
Calculation of load on the beam
wall Assume steel frame having a dead load of Steel HBC Glass g= g= g= 77 14 25 KN/m3 KN/m3 KN/m3 0.236 KN/m window h = 1.8 wall - window (H-h) = 0.9 wall H = 2.7
External wall load on the beam with window 200mm thick HCB wall = 1.3 x 14 KN/m3 x 0.20 x 0.9 = 3.276 KN/m 25mm thick plastering on both side = 1.3 x 23 KN/m3 x 0.05 x 2.7 = 4.043 KN/m Wt. of glass = 1.3 x 25 KN/m3 x 0.006 x 1.8 = 0.351 KN/m Wt. of window including with frame = 1.3 x 0.236 KN/m x 1.2 = 0.369 KN/m Factored total load = 7.994 KN/m Interior wall load on the beam
150mm thick HCB wall 25mm thick plastering on both side
= =
1.3 x 14 KN/m3 x 0.15 x 2.7 = 7.371 KN/m 1.3 x 23 KN/m3 x 0.05 x 2.7 = 4.043 KN/m Factored total load = 11.414 KN/m
External wall load on the beam without window 200mm thick HCB wall 25mm thick plastering on both side = = 1.3 x 14 KN/m3 x 0.2 x 2.7 = 9.828 KN/m 1.3 x 23 KN/m3 x 0.05 x 2.7 = 4.043 KN/m Factored total load = 13.871 KN/m
Parapet wall load on the beam with height,h(m) = 0.6 200mm thick HCB wall = 1.3 x 14 KN/m3 x 0.2 x 0.6 = 2.184 KN/m 25mm thick plastering on both side = 1.3 x 23 KN/m3 x 0.05 x 0.6 = 0.897 KN/m Factored total load = 3.081 KN/m
Summary From Exterior wall with window From Interior wall From Exterior wall without window FromParapet wall - Live load = 0.250 KN/m2
Factored Total load 8 KN/m 12 KN/m 14 KN/m 4 KN/m [EBCS-1 Table2.10]
REFERENCE
m m m
1 Table2.10]