Cooling Load Calculations AG

The document contains data about room numbers, solar time, and total sensible cooling loads (Q total sensible W) for different months including June, July, August and September. It includes information about external and internal cooling loads, conduction, solar, lights, people and equipment for calculation of total cooling load.

Uploaded by

uddinnadeem
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views5 pages

Cooling Load Calculations AG

The document contains data about room numbers, solar time, and total sensible cooling loads (Q total sensible W) for different months including June, July, August and September. It includes information about external and internal cooling loads, conduction, solar, lights, people and equipment for calculation of total cooling load.

Uploaded by

uddinnadeem
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 5

Room No

AG

12
66310

14
67475

12
71976

14
73299

12
75628.1

14
76793.1

12
81294.1

14
82617.1

July

June
16
67744

18
66437

12
66442

14
67590

16
72676

18
70410

12
67916

14
69077

16
77062.1

18
75755.1

12
75760.1

14
76908.1

18
79728.1

12
77234.1

14
78395.1

September

16
67896

18
66679

Month
Solar Time,h
Q total sensible W

18
67434

Month
Solar Time,h
Q total sensible W

August

July

16
69068

June

September
16
81994.1

23.47

16
77214.1

Month
Solar Time,h
18
75997.1 Q total W

August

: TON

82617.1

: W

16
78386.1

:Q Total

Month
Solar Time,h
18
76752.1 Q total W

Cool.Lo

Room No

AG

MONTH :
LATITUDE :
DAILY RANGE :

EXTERNAL COOLING LOAD

CONDUCTION

ITEM
ROOF11
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS

JUNE

JUNE
24 , 26
18 CO

ORIANU
A
UxA
m2
TATIO w/m2.c
HOR.
0.44
0
0
N
0.43 104.32 44.86
S
0.43 181.76 78.16
E
0.43 148.56 63.88
W
0.43
62.4
26.83
NE
0.43
0
0
NW
0.43
0
0
SE
0.43
32.24
0
SW
0.43
0
0
HOR.
4
0
0
N
4
22.08 88.32
S
4
37.77 151.08
E
4
28.64 114.56
W
4
5.6
22.4
NE
4
0
0
NW
4
0
0
SE
4
11.76 47.04
SW
4
0
0

ITEM

U
1.2
0
0
0

PARTITION
PARTITION
PARTITION
CEILING
CEILING
FLOOR
FLOOR

unsha.
shaded

GLASS

SOLAR
LIGHTS
PEOPLE
EQUIP.

INTERNAL COOLING LOAD

No. of
people

No. of
EQU
25

q /A
w/m2
25

A
m2
1067

W.B
24.8 CO

RH

ZONE

CLTD
12
10
5
7
20
5
14
5
17
5
5
5
5
5
5
5
5
5
5

FLOOR

ROOM

14
15
7
14
21
8
14
7
20
10
7
7
7
7
7
7
7
7
7

16
20
10
18
19
15
14
11
20
18
8
8
8
8
8
8
8
8
8

T
2
0
0
0

S.C.

SHGF

A . SC . SHGF

0
22.08
37.77
28.64
5.6
0
0
11.76
0
0
22.08
37.77
28.64
5.6
0
0
11.76
0

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6

880
174
136
688
688
581
581
369
369
98
142
126
145
145
148
148
129
129

0
2305
3082
11823
2312
0
0
2604
0
0
0
0
0
0
0
0
0
0

INPUT

U.F

CLF

18
24
11
18
18
24
14
18
18
24
7
7
7
7
7
7
7
7
7

Correc. Correc. Total


Tr + To Correc.
L.M
12
0.5
4.1
4.6
10.95
1.6
4.1
5.7
10.7
-3.3
4.1
0.8
7.8
0
4.1
4.1
24.1
0
4.1
4.1
9.1
1.6
4.1
5.7
19.7
1.6
4.1
5.7
10.7
-2.2
4.1
1.9
18.9
-2.2
4.1
1.9
6.9
0.5
4.1
4.6
9.6
1.6
4.1
5.7
10.7
-3.3
4.1
0.8
5.8
0
4.1
4.1
9.1
0
4.1
4.1
9.1
1.6
4.1
5.7
10.7
1.6
4.1
5.7
10.7
-2.2
4.1
1.9
6.9
-2.2
4.1
1.9
6.9

(CLTD) corrected
14
16
14.7
18.45
12.7
15.7
14.8
18.8
25.1
23.1
12.1
19.1
19.7
19.7
12.7
16.7
21.9
21.9
11.9
19.9
11.6
12.6
12.7
13.7
7.8
8.8
11.1
12.1
11.1
12.1
12.7
13.7
12.7
13.7
8.9
9.9
8.9
9.9

Q. SENSIBLE
W
HR. 12 HR. 14 HR. 16 HR. 18
0
0
0
0
480
570
704
749
610
1157
1469
1469
1540
1603
1476
1412
244
325
512
754
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
945
1122
1210
1122
876
1178
1330
1178
1042
1272
1386
1272
204
249
271
249
0
0
0
0
0
0
0
0
325
419
466
419
0
0
0
0

18
21.45
16.7
18.8
22.1
28.1
19.7
23.7
19.9
25.9
11.6
12.7
7.8
11.1
11.1
12.7
12.7
8.9
8.9

0
0
0
0
0
0
0
CLF
12
0.59
0.7
0.52
0.39
0.14
0.33
0.17
0.51
0.23
0.85
0.89
0.83
0.27
0.17
0.27
0.21
0.49
0.38

14
0.67
0.75
0.58
0.31
0.29
0.3
0.21
0.4
0.44
0.81
0.86
0.68
0.22
0.53
0.24
0.3
0.28
0.75

16
0.62
0.74
0.47
0.26
0.5
0.26
0.42
0.33
0.58
0.58
0.75
0.35
0.17
0.82
0.2
0.73
0.22
0.81

18
0.47
0.79
0.36
0.21
0.55
0.21
0.54
0.25
0.53
0.25
0.91
0.19
0.11
0.61
0.12
0.69
0.13
0.45
TOTAL

0
1614
1603
4611
324
0
0
1328
0
0
0
0
0
0
0
0
0
0

0
1729
1788
3665
670
0
0
1042
0
0
0
0
0
0
0
0
0
0

0
1706
1449
3074
1156
0
0
859
0
0
0
0
0
0
0
0
0
0

0
1821
1110
2483
1272
0
0
651
0
0
0
0
0
0
0
0
0
0

15746

16789

17068

15961

26675

Sens. H.G.

100

75
QS
w/ITEM
100

INFILITRATION AIR :

7500
U.F.
1
0.34 x V x n x

2500
T

0.17

V
2134

T
22
QS+ 10% :

LATENT
LOAD

SHEET NO.

50%

A
0
0
0
0

ORIANTATIO
HOR.
N
S
E
W
NE
NW
SE
SW
HOR.
N
S
E
W
NE
NW
SE
SW

ITEM

TYPE

D.B
Outside 46 CO
24 CO
Inside

ITEM
PEOPLE
EQUIPMENT
EQUIPMENT

INFILITRATION AIR :

Ql / ITEM
55

0.87 x V x n x

NO.
100

66442

CLF
1
1
1
0.435

7981
67590 67896
QL LATENT
5500
0
0

V
2134

W
3.2

66679

2971

21.94

: TON

77214

: W

QL+ 10% :
:QT W

9318.1
75760

76908

77214

75997

JULY
MONTH :
LATITUDE :
DAILY RANGE :

EXTERNAL COOLING LOAD

CONDUCTION

ITEM
ROOF11
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS

JULY
24 ,26
18 CO

ORIANU
A
UxA
m2
TATIO w/m2.c
HOR.
0.44
0
0
N
0.43 104.32 44.86
S
0.43 181.76 78.16
E
0.43 148.56 63.88
W
0.43
62.4
26.83
NE
0.43
0
0
NW
0.43
0
0
SE
0.43
32.24 13.86
SW
0.43
0
0
HOR.
4
0
0
N
4
22.08 88.32
S
4
37.77 151.08
E
4
28.64 114.56
W
4
5.6
22.4
NE
4
0
0
NW
4
0
0
SE
4
11.76 47.04
SW
4
0
0

ITEM

U
1.2
0
0
0
0
0
0

PARTITION
PARTITION
PARTITION
CEILING
CEILING
FLOOR
FLOOR

unsha.
shaded

GLASS

SOLAR
LIGHTS
PEOPLE
EQUIP.

INTERNAL COOLING LOAD

No. of
people

No. of
EQU
25

q /A
w/m2
25

A
m2
1067

W.B
24.8 CO

RH

ZONE

CLTD
12
10
5
7
20
5
14
5
17
5
5
5
5
5
5
5
5
5
5

FLOOR

ROOM

14
15
7
14
21
8
14
7
20
10
7
7
7
7
7
7
7
7
7

16
20
10
18
19
15
14
11
20
18
8
8
8
8
8
8
8
8
8

T
2
0
0
0
0
0
0

S.C.

SHGF

A . SC . SHGF

0
22.08
37.77
28.64
5.6
0
0
11.76
0
0
22.08
37.77
28.64
5.6
0
0
11.76
0

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0
0
0
0
0
0
0
0
0

877
142
145
672
672
555
555
407
407
98
142
129
148
148
145
145
133
133

0
1881
3286
11548
2258
0
0
2872
0
0
0
0
0
0
0
0
0
0

INPUT

U.F

CLF

18
24
11
18
18
24
14
18
18
24
7
7
7
7
7
7
7
7
7

Correc. Correc. Total


Tr + To Correc.
L.M
12
0.5
4.1
4.6
10.95
0.5
4.1
4.6
9.6
-3.3
4.1
0.8
7.8
0
4.1
4.1
24.1
0
4.1
4.1
9.1
1.1
4.1
5.2
19.2
1.1
4.1
5.2
10.2
-3.3
4.1
0.8
17.8
-3.3
4.1
0.8
5.8
0.5
4.1
4.6
9.6
0.5
4.1
4.6
9.6
-3.3
4.1
0.8
5.8
0
4.1
4.1
9.1
0
4.1
4.1
9.1
1.1
4.1
5.2
10.2
1.1
4.1
5.2
10.2
-3.3
4.1
0.8
5.8
-3.3
4.1
0.8
5.8

(CLTD) corrected
14
16
14.7
18.45
11.6
14.6
14.8
18.8
25.1
23.1
12.1
19.1
19.2
19.2
12.2
16.2
20.8
20.8
10.8
18.8
11.6
12.6
11.6
12.6
7.8
8.8
11.1
12.1
11.1
12.1
12.2
13.2
12.2
13.2
7.8
8.8
7.8
8.8

Q. SENSIBLE
W
HR. 12 HR. 14 HR. 16 HR. 18
0
0
0
0
431
520
655
700
610
1157
1469
1469
1540
1603
1476
1412
244
325
512
754
0
0
0
0
0
0
0
0
247
288
288
261
0
0
0
0
0
0
0
0
848
1025
1113
1025
876
1178
1330
1178
1042
1272
1386
1272
204
249
271
249
0
0
0
0
0
0
0
0
273
367
414
367
0
0
0
0

18
21.45
15.6
18.8
22.1
28.1
19.2
23.2
18.8
24.8
11.6
11.6
7.8
11.1
11.1
12.2
12.2
7.8
7.8

0
0
0
0
0
0
0
CLF
12
0.59
0.7
0.52
0.39
0.14
0.33
0.17
0.51
0.23
0.85
0.89
0.83
0.27
0.17
0.27
0.21
0.49
0.38

14
0.67
0.75
0.58
0.31
0.29
0.3
0.21
0.4
0.44
0.81
0.86
0.68
0.22
0.53
0.24
0.3
0.28
0.75

16
0.62
0.74
0.47
0.26
0.5
0.26
0.42
0.33
0.58
0.58
0.75
0.35
0.17
0.82
0.2
0.73
0.22
0.81

18
0.47
0.79
0.36
0.21
0.55
0.21
0.54
0.25
0.53
0.25
0.91
0.19
0.11
0.61
0.12
0.69
0.13
0.45
TOTAL

0
1317
1709
4504
316
0
0
1465
0
0
0
0
0
0
0
0
0
0

0
1411
1906
3580
655
0
0
1149
0
0
0
0
0
0
0
0
0
0

0
1392
1544
3002
1129
0
0
948
0
0
0
0
0
0
0
0
0
0

0
1486
1183
2425
1242
0
0
718
0
0
0
0
0
0
0
0
0
0

15626

16685

16929

15741

26675

Sens. H.G.

100

75
QS
w/ITEM
100

INFILITRATION AIR :

7500
U.F.
1
0.34 x V x n x

2500
T

0.17

V
2134

T
22
QS+ 10% :

LATENT
LOAD

SHEET NO.

50%

A
0
0
0
0
0
0
0

ORIANTATIO
HOR.
N
S
E
W
NE
NW
SE
SW
HOR.
N
S
E
W
NE
NW
SE
SW

ITEM

TYPE

D.B
Outside 46 CO
24 CO
Inside

ITEM
PEOPLE
EQUIPMENT
EQUIPMENT

INFILITRATION AIR :

Ql / ITEM
55
0
0
0.87 x V x n x

NO.
100
0
0
W

66310

CLF
1
1
1
0.435

7981
67475 67744
QL LATENT
5500
0
0

V
2134

W
3.2

66437

2971

21.89

: TON

77062

: W

QL+ 10% :
:QT W

9318.1
75628

76793

77062

75755

AUGUST
MONTH :
LATITUDE :
DAILY RANGE :

EXTERNAL COOLING LOAD

CONDUCTION

ITEM
ROOF11
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS

AUGUST
24 , 26
18 CO

ORIANU
A
UxA
m2
TATIO w/m2.c
HOR.
0.44
0
0
N
0.43 104.32 44.86
S
0.43 181.76 78.16
E
0.43 148.56 63.88
W
0.43
62.4
26.83
NE
0.43
0
0
NW
0.43
0
0
SE
0.43
32.24 13.86
SW
0.43
0
0
HOR.
4
0
0
N
4
22.08 88.32
S
4
37.77 151.08
E
4
28.64 114.56
W
4
5.6
22.4
NE
4
0
0
NW
4
0
0
SE
4
11.76 47.04
SW
4
0
0

ITEM

U
1.2
0
0
0
0
0
0

PARTITION
PARTITION
PARTITION
CEILING
CEILING
FLOOR
FLOOR

LIGHTS
PEOPLE

INTERNAL COOLING LOAD

No. of
people

EQUIP.

shaded

GLASS

SOLAR

unsha.

ITEM

TYPE

No. of
EQU
25

D.B
Outside 46 CO
24 CO
Inside

A
0
0
0
0
0
0
0

T
2
0
0
0
0
0
0

W.B
24.8 CO

RH

CLTD
12
10
5
7
20
5
14
5
17
5
5
5
5
5
5
5
5
5
5

14
15
7
14
21
8
14
7
20
10
7
7
7
7
7
7
7
7
7

16
20
10
18
19
15
14
11
20
18
8
8
8
8
8
8
8
8
8

FLOOR

ROOM

18
24
11
18
18
24
14
18
18
24
7
7
7
7
7
7
7
7
7

Correc. Correc. Total


Tr + To Correc.
L.M
12
0
4.1
4.1
10.95
-1.1
4.1
3
8
-1.6
4.1
2.5
9.5
-0.5
4.1
3.6
23.6
-0.5
4.1
3.6
8.6
0
4.1
4.1
18.1
0
4.1
4.1
9.1
-1.6
4.1
2.5
19.5
-1.6
4.1
2.5
7.5
0
4.1
4.1
9.1
-1.1
4.1
3
8
-1.6
4.1
2.5
7.5
-0.5
4.1
3.6
8.6
-0.5
4.1
3.6
8.6
0
4.1
4.1
9.1
0
4.1
4.1
9.1
-1.6
4.1
2.5
7.5
-1.6
4.1
2.5
7.5

(CLTD) corrected
14
16
14.7
18.45
10
13
16.5
20.5
24.6
22.6
11.6
18.6
18.1
18.1
11.1
15.1
22.5
22.5
12.5
20.5
11.1
12.1
10
11
9.5
10.5
10.6
11.6
10.6
11.6
11.1
12.1
11.1
12.1
9.5
10.5
9.5
10.5

Q. SENSIBLE
W
HR. 12 HR. 14 HR. 16 HR. 18
0
0
0
0
359
449
583
628
743
1290
1602
1602
1508
1571
1444
1380
231
311
499
741
0
0
0
0
0
0
0
0
270
312
312
284
0
0
0
0
0
0
0
0
707
883
972
883
1133
1435
1586
1435
985
1214
1329
1214
193
237
260
237
0
0
0
0
0
0
0
0
353
447
494
447
0
0
0
0

18
21.45
14
20.5
21.6
27.6
18.1
22.1
20.5
26.5
11.1
10
9.5
10.6
10.6
11.1
11.1
9.5
9.5

S.C.

SHGF

A . SC . SHGF

0.6

22.08
37.77
28.64
5.6
0
0
11.76
0
0
22.08
37.77
28.64
5.6
0
0
11.76
0

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0
0
0
0
0
0
0
0
0

874
120
227
694
694
492
492
511
511
88
133
133
145
145
136
136
136
136

0
1590
5144
11926
2332
0
0
3606
0
0
0
0
0
0
0
0
0
0

q /A

INPUT

U.F

CLF

w/m2
25

CLF
12
0.59
0.7
0.52
0.39
0.14
0.33
0.17
0.51
0.23
0.85
0.89
0.83
0.27
0.17
0.27
0.21
0.49
0.38

14
0.67
0.75
0.58
0.31
0.29
0.3
0.21
0.4
0.44
0.81
0.86
0.68
0.22
0.53
0.24
0.3
0.28
0.75

16
0.62
0.74
0.47
0.26
0.5
0.26
0.42
0.33
0.58
0.58
0.75
0.35
0.17
0.82
0.2
0.73
0.22
0.81

18
0.47
0.79
0.36
0.21
0.55
0.21
0.54
0.25
0.53
0.25
0.91
0.19
0.11
0.61
0.12
0.69
0.13
0.45
TOTAL

0
1113
2675
4651
326
0
0
1839
0
0
0
0
0
0
0
0
0
0

0
1193
2984
3697
676
0
0
1442
0
0
0
0
0
0
0
0
0
0

0
1177
2418
3101
1166
0
0
1190
0
0
0
0
0
0
0
0
0
0

0
1256
1852
2504
1283
0
0
902
0
0
0
0
0
0
0
0
0
0

17086

18141

18133

16648

26675

Sens. H.G.

100

75
QS
w/ITEM
100

INFILITRATION AIR :

7500
U.F.
1

2500

0.34 x V x n x

0.17

2134

22
QS+ 10% :

LATENT
LOAD

SHEET NO.

0
0
0
0
0
0
0

ORIANTATIO
HOR.
N
S
E
W
NE
NW
SE
SW
HOR.
N
S
E
W
NE
NW
SE
SW

A
m2
1067

ZONE

50%

ITEM

Ql / ITEM

NO.

67916

CLF

PEOPLE
EQUIPMENT
EQUIPMENT

55
0
0

100
0
0

1
1
1

INFILITRATION AIR :

0.87 x V x n x

0.435

7981
69077 69068 67434
QL LATENT
W
5500
0
0

V
2134

W
3.2

2971

22.27

: TON

78395

: W

QL+ 10% :
:QT W

9318.1
77234

78395

78386

76752

SEPTEMBER
MONTH :
LATITUDE :
DAILY RANGE :

EXTERNAL COOLING LOAD

CONDUCTION

ITEM
ROOF11
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
WALL E
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS
GLASS

SEPTEMBER
24 , 26
18 CO

ORIANU
A
UxA
m2
TATIO w/m2.c
HOR.
0.44
0
0
N
0.43 104.32 44.86
S
0.43 181.76 78.16
E
0.43 148.56 63.88
W
0.43
62.4
26.83
NE
0.43
0
0
NW
0.43
0
0
SE
0.43
32.24 13.86
SW
0.43
0
0
HOR.
4
0
0
N
4
22.08 88.32
S
4
37.77 151.08
E
4
28.64 114.56
W
4
5.6
22.4
NE
4
0
0
NW
4
0
0
SE
4
11.76 47.04
SW
4
0
0

ITEM

U
1.2
0
0
0
0
0
0

PARTITION
PARTITION
PARTITION
CEILING
CEILING
FLOOR
FLOOR

LIGHTS
PEOPLE

INTERNAL COOLING LOAD

No. of
people

EQUIP.

shaded

GLASS

SOLAR

unsha.

ITEM

TYPE

No. of
EQU

D.B
Outside 46 CO
24 CO
Inside

A
0
0
0
0
0
0
0

T
2
0
0
0
0
0
0

W.B
24.8 CO

RH

CLTD
12
10
5
7
20
5
14
5
17
5
5
5
5
5
5
5
5
5
5

14
15
7
14
21
8
14
7
20
10
7
7
7
7
7
7
7
7
7

16
20
10
18
19
15
14
11
20
18
8
8
8
8
8
8
8
8
8

FLOOR

ROOM

18
24
11
18
18
24
14
18
18
24
7
7
7
7
7
7
7
7
7

Correc. Correc. Total


Tr + To Correc.
L.M
12
-1.6
4.1
2.5
10.95
-1.6
4.1
2.5
7.5
2.2
4.1
6.3
13.3
-0.5
4.1
3.6
23.6
-0.5
4.1
3.6
8.6
-1.6
4.1
2.5
16.5
-1.6
4.1
2.5
7.5
0.5
4.1
4.6
21.6
0.5
4.1
4.6
9.6
-1.6
4.1
2.5
7.5
-1.6
4.1
2.5
7.5
2.2
4.1
6.3
11.3
-0.5
4.1
3.6
8.6
-0.5
4.1
3.6
8.6
-1.6
4.1
2.5
7.5
-1.6
4.1
2.5
7.5
0.5
4.1
4.6
9.6
0.5
4.1
4.6
9.6

(CLTD) corrected
14
16
14.7
18.45
9.5
12.5
20.3
24.3
24.6
22.6
11.6
18.6
16.5
16.5
9.5
13.5
24.6
24.6
14.6
22.6
9.5
10.5
9.5
10.5
13.3
14.3
10.6
11.6
10.6
11.6
9.5
10.5
9.5
10.5
11.6
12.6
11.6
12.6

Q. SENSIBLE
W
HR. 12 HR. 14 HR. 16 HR. 18
0
0
0
0
336
426
561
606
1040
1587
1899
1899
1508
1571
1444
1380
231
311
499
741
0
0
0
0
0
0
0
0
299
341
341
313
0
0
0
0
0
0
0
0
662
839
927
839
1707
2009
2160
2009
985
1214
1329
1214
193
237
260
237
0
0
0
0
0
0
0
0
452
546
593
546
0
0
0
0

18
21.45
13.5
24.3
21.6
27.6
16.5
20.5
22.6
28.6
9.5
9.5
13.3
10.6
10.6
9.5
9.5
11.6
11.6

S.C.

SHGF

A . SC . SHGF

0
22.08
37.77
28.64
5.6
0
0
11.76
0
0
22.08
37.77
28.64
5.6
0
0
11.76
0

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0
0
0
0
0
0
0
0
0

839
110
423
700
700
375
375
650
650
73
117
129
129
129
120
120
133
133

0
1457
9586
12029
2352
0
0
4586
0
0
0
0
0
0
0
0
0
0

q /A

INPUT

U.F

CLF

w/m2
25

CLF
12
0.59
0.7
0.52
0.39
0.14
0.33
0.17
0.51
0.23
0.85
0.89
0.83
0.27
0.17
0.27
0.21
0.49
0.38

14
0.67
0.75
0.58
0.31
0.29
0.3
0.21
0.4
0.44
0.81
0.86
0.68
0.22
0.53
0.24
0.3
0.28
0.75

16
0.62
0.74
0.47
0.26
0.5
0.26
0.42
0.33
0.58
0.58
0.75
0.35
0.17
0.82
0.2
0.73
0.22
0.81

18
0.47
0.79
0.36
0.21
0.55
0.21
0.54
0.25
0.53
0.25
0.91
0.19
0.11
0.61
0.12
0.69
0.13
0.45
TOTAL

0
1020
4985
4691
329
0
0
2339
0
0
0
0
0
0
0
0
0
0

0
1093
5560
3729
682
0
0
1834
0
0
0
0
0
0
0
0
0
0

0
1078
4505
3128
1176
0
0
1513
0
0
0
0
0
0
0
0
0
0

0
1151
3451
2526
1294
0
0
1147
0
0
0
0
0
0
0
0
0
0

20777

21979

21413

19353

26675

Sens. H.G.

100

75

25

QS
w/ITEM
100

INFILITRATION AIR :

7500
U.F.
1

2500

0.34 x V x n x

0.17

V
2134

T
22
QS+ 10% :

LATENT
LOAD

SHEET NO.

0
0
0
0
0
0
0

ORIANTATIO
HOR.
N
S
E
W
NE
NW
SE
SW
HOR.
N
S
E
W
NE
NW
SE
SW

A
m2
1067

ZONE

50%

ITEM

Ql / ITEM

NO.

5500

55

100

EQUIPMENT
EQUIPMENT

0
0

0
0

1
1

0.87 x V x n x

7981
73299 72676
QL LATENT

PEOPLE

INFILITRATION AIR :

71976

CLF

0.435

70410

0
0
V
2134

W
3.2

2971

23.47

: TON

82617

: W

QL+ 10% :
:QT W

9318.1
81294

82617

81994

79728

You might also like