Replacement: Manual Transmission/Transaxle
Replacement: Manual Transmission/Transaxle
REPLACEMENT
HINT: COMPONENTS: See page 415 1. REMOVE FLOOR SHIFT SHIFT LEVER KNOB SUBASSY 2. REMOVE CONSOLE PANEL UPPER (See page 7110) 3. REMOVE PARKING BRAKE HOLE COVER SUBASSY (See page 7110) 4. REMOVE CONSOLE BOX SUBASSY REAR (See page 7110)
5. (a)
SEPARATE FLOOR SHIFT CABLE TRANSMISSION CONTROL SHIFT Separate the end of the shift cable from the shift lever assy.
D26974
(b) (c)
Using a screwdriver, release the cable outer spring. Turn the lock, separate the shift cable from the shift lever retainer.
Lock
D26973
6. (a)
SEPARATE FLOOR SHIFT CABLE TRANSMISSION CONTROL SELECT Separate the end of the select cable from the shift lever assy.
D26976
(b) (c)
Using a screwdriver, release the cable outer spring. Turn the lock, separate the select cable from the shift lever retainer.
Author :
Date :
1406
417
MANUAL TRANSMISSION/TRANSAXLE FLOOR SHIFT SHIFT LEVER ASSY
7. (a)
REMOVE FLOOR SHIFT SHIFT LEVER ASSY Remove the 4 bolts and shift lever assy.
D26889
8. (a)
INSTALL FLOOR SHIFT SHIFT LEVER ASSY Install the shift lever assy with the 4 bolts. Torque: 12 Nm (120 kgfcm, 9 ftlbf)
D26889
9.
Cable Outer spring
Lock
D26915
CONNECT FLOOR SHIFT CABLE TRANSMISSION CONTROL SHIFT (a) Connect the shift cable to the retainer of shift lever assy, turn the lock. NOTICE: The projecting part of the lock should face upward when the shift cable is installed. (b) Install the cable outer spring to the lock. NOTICE: Make sure that after installation the cable outer spring is moved to the place shown in the illustration.
(c)
Connect the end of the shift cable to the shift lever assy.
D26974
Author :
Date :
1407
418
MANUAL TRANSMISSION/TRANSAXLE FLOOR SHIFT SHIFT LEVER ASSY
10.
Cable Outer spring
Lock
D26916
CONNECT FLOOR SHIFT CABLE TRANSMISSION CONTROL SELECT (a) Connect the select cable to the retainer of shift lever assy, turn the lock. NOTICE: The projecting part of the lock should face upward when the select cable is installed. (b) Install the cable outer spring to the lock. NOTICE: Make sure that after installation the cable outer spring is moved to the place shown in the illustration.
(c)
Connect the end of the select cable to the shift lever assy.
D26976
Author :
Date :
1408