#ifndef lint
static const char rcsid[] =
- "@(#) $Header: /tcpdump/master/libpcap/gencode.c,v 1.145 2001-01-14 21:26:52 guy Exp $ (LBL)";
+ "@(#) $Header: /tcpdump/master/libpcap/gencode.c,v 1.146 2001-01-15 00:03:40 guy Exp $ (LBL)";
#endif
#ifdef HAVE_CONFIG_H
case LLCSAP_IPX:
/*
- * Check both for 802.2 frames with the IPX LSAP as
- * the DSAP and for Netware 802.3 frames.
+ * Ethernet_II frames, which are Ethernet
+ * frames with a frame type of ETHERTYPE_IPX;
+ *
+ * Ethernet_802.3 frames, which have a frame
+ * type of LINUX_SLL_P_802_3;
+ *
+ * Ethernet_802.2 frames, which are 802.3
+ * frames with an 802.2 LLC header (i.e, have
+ * a frame type of LINUX_SLL_P_802_2) and
+ * with the IPX LSAP as the DSAP in the LLC
+ * header;
+ *
+ * Ethernet_SNAP frames, which are 802.3
+ * frames with an LLC header and a SNAP
+ * header and with an OUI of 0x000000
+ * (encapsulated Ethernet) and a protocol
+ * ID of ETHERTYPE_IPX in the SNAP header.
*
- * This generates code to check for 802.2 frames
- * with the IPX LSAP.
+ * First, do the checks on LINUX_SLL_P_802_2
+ * frames; generate the check for either
+ * Ethernet_802.2 or Ethernet_SNAP frames, and
+ * then put a check for LINUX_SLL_P_802_2 frames
+ * before it.
*/
- b0 = gen_cmp(off_linktype, BPF_H, LINUX_SLL_P_802_2);
- b1 = gen_cmp(off_linktype + 2, BPF_B,
+ b0 = gen_cmp(off_linktype + 2, BPF_B,
(bpf_int32)LLCSAP_IPX);
+ b1 = gen_snap(0x000000, ETHERTYPE_IPX,
+ off_linktype + 2);
+ gen_or(b0, b1);
+ b0 = gen_cmp(off_linktype, BPF_H, LINUX_SLL_P_802_2);
gen_and(b0, b1);
/*
*/
b0 = gen_cmp(off_linktype, BPF_H, LINUX_SLL_P_802_3);
gen_or(b0, b1);
+
+ /*
+ * Now add the check for Ethernet_II frames, and
+ * do that before checking for the other frame
+ * types.
+ */
+ b0 = gen_cmp(off_linktype, BPF_H,
+ (bpf_int32)ETHERTYPE_IPX);
+ gen_or(b0, b1);
return b1;
case ETHERTYPE_ATALK: