Nolan, D.R., Gower, A.L., Destrade, M., Ogden, R.W. and McGarry, J.P. (2014) A robust anisotropic hyperelastic formulation for the modelling of soft tissue. Journal of the Mechanical Behavior of Biomedical Materials, 39, pp. 48-60. (doi: 10.1016/j.jmbbm.2014.06.016)
Full text not currently available from Enlighten.
Publisher's URL: http://dx.doi.org/10.1016/j.jmbbm.2014.06.016
Abstract
The Holzapfel–Gasser–Ogden (HGO) model for anisotropic hyperelastic behaviour of collagen fibre reinforced materials was initially developed to describe the elastic properties of arterial tissue, but is now used extensively for modelling a variety of soft biological tissues. Such materials can be regarded as incompressible, and when the incompressibility condition is adopted the strain energy Ψ of the HGO model is a function of one isotropic and two anisotropic deformation invariants. A compressible form (HGO-C model) is widely used in finite element simulations whereby the isotropic part of Ψ is decoupled into volumetric and isochoric parts and the anisotropic part of Ψ is expressed in terms of isochoric invariants. Here, by using three simple deformations (pure dilatation, pure shear and uniaxial stretch), we demonstrate that the compressible HGO-C formulation does not correctly model compressible anisotropic material behaviour, because the anisotropic component of the model is insensitive to volumetric deformation due to the use of isochoric anisotropic invariants. In order to correctly model compressible anisotropic behaviour we present a modified anisotropic (MA) model, whereby the full anisotropic invariants are used, so that a volumetric anisotropic contribution is represented. The MA model correctly predicts an anisotropic response to hydrostatic tensile loading, whereby a sphere deforms into an ellipsoid. It also computes the correct anisotropic stress state for pure shear and uniaxial deformation. To look at more practical applications, we developed a finite element user-defined material subroutine for the simulation of stent deployment in a slightly compressible artery. Significantly higher stress triaxiality and arterial compliance are computed when the full anisotropic invariants are used (MA model) instead of the isochoric form (HGO-C model).
Item Type: | Articles |
---|---|
Status: | Published |
Refereed: | Yes |
Glasgow Author(s) Enlighten ID: | Ogden, Professor Raymond |
Authors: | Nolan, D.R., Gower, A.L., Destrade, M., Ogden, R.W., and McGarry, J.P. |
College/School: | College of Science and Engineering > School of Mathematics and Statistics > Mathematics |
Journal Name: | Journal of the Mechanical Behavior of Biomedical Materials |
Publisher: | Elsevier |
ISSN: | 1751-6161 |
ISSN (Online): | 1878-0180 |
University Staff: Request a correction | Enlighten Editors: Update this record