Media 000427209: Humerus
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000427209
Media type
Mesh
Object element or part
Humerus
Object represented
Object taxonomy
Anura indet.
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Alfred Lemierre
Date created
March 01, 2022
Date uploaded
March 01, 2022

FILE OBJECT DETAILS Field Definitions

File name
Appendix_S21_UCRC-PV104.stl
File format(s)
STL
File size
83.4 MB
Points
874120
Polygons
1749200
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
1820.608, 4565.865, 5111.042
Centroid coordinates
950.763, 1604.026, 1718.747
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ucrc:PV104 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
Datos|X A
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
Geometry
Shading correction
Yes
Frame averaging
3
Projections
2000
Voltage
80
Power
14.4
Amperage
180
Surrounding material
air
X-ray tube type
--
Target type
Transmission
Detector type
--
Detector pixels X
2014
Detector pixels size X
--
Detector pixels Y
2024
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungston
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000351812: Humerus [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Edward Stanley
Event date
March 24, 2021
Software
DatosX R
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000351812: Humerus [CTImageSeries] [CT] was processed to create derived Media 000427209: Humerus [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Alfred Lemierre
Event date
March 01, 2022
Software
Mimics 21.0
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000427209: Humerus [Mesh] [CT] (this media)