Media 000427202: Sacral Vertebra
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000427202: Sacral Vertebra
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000427202
Media type
Mesh
Object element or part
Sacral vertebra
Object represented
Object taxonomy
Cretadhefdaa taouzensis
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Alfred Lemierre
Date created
March 01, 2022
Date uploaded
March 01, 2022
FILE OBJECT DETAILS Field Definitions
File name
Appendix_S20_UCRC-PV103.stl
File format(s)
STL
File size
286 MB
Points
3011788
Polygons
5988252
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
5309.172, 6139.368, 7505.702
Centroid coordinates
2390.717, 2938.128, 3102.470
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ucrc:PV103
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
Datos|X A
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
Geometry
Shading correction
No
Frame averaging
3
Projections
2000
Voltage
80
Power
16
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
2014
Detector pixels size X
--
Detector pixels Y
2024
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungston
Rotation number
--
Phase contrast
No
Optical magnification
Yes
Acquisition type
Sequenced
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000351822: Sacral Vertebra [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Edward Stanley
Event date
March 24, 2021
Software
DatosX R
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000351822: Sacral Vertebra [CTImageSeries] [CT]
was processed
to create
derived
Media 000427202: Sacral Vertebra [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Alfred Lemierre
Event date
March 01, 2022
Software
Mimics 21.0
Description
--
Description attachment
None