Media 000427196: Maxilla
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000427196: Maxilla
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000427196
Media type
Mesh
Object element or part
Maxilla
Object represented
Object taxonomy
Cretadhefdaa taouzensis
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Alfred Lemierre
Date created
March 01, 2022
Date uploaded
March 01, 2022
FILE OBJECT DETAILS Field Definitions
File name
Appendix_S13_UCRC-PV96.stl
File format(s)
STL
File size
104 MB
Points
1094560
Polygons
2184408
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
2511.746, 6161.591, 3546.462
Centroid coordinates
1346.909, 3301.462, 1575.530
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ucrc:PV96
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
Datos X|a
Description
MicroCT of UCRC PV96
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
0.333096
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
1200
Voltage
80kV
Power
16W
Amperage
80uA
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungston (W)
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000389771: Maxilla [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Edward Stanley
Event date
--
Software
Datos X|r
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000389771: Maxilla [CTImageSeries] [CT]
was processed
to create
derived
Media 000427196: Maxilla [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Alfred Lemierre
Event date
March 01, 2022
Software
Mimics 21.0
Description
--
Description attachment
None