Tufts University Digital Dentistry Mini-Residency 2024
4 module course from February to June, 2024.
25% off with our promo code. Learn more and register here!
The Inliant System has received FDA 510K clearance
What Is Dynamic
Surgical Navigation?
Dynamic Surgical Navigation is free-hand guided surgery with real-time motion tracking of the clinician’s handpiece and patient position. The precise angulation and position of the drill is calculated and overlaid on the patient’s CBCT scan in real-time and displayed on the monitor.
How Does It Work?
A fiducial, recognized as an anchor point, is affixed to the patient and held in place with a stent during the initial CBCT scan, and again during surgery.
During surgery a patient tracker is attached to the stent. Cameras track markers located on both patient tracker and dental handpiece to determine the relative position of the drill and patient which is displayed on a monitor.
1.Handpiece
With nothing attached to the handpiece, the clinician’s ergonomics and tactile feedback remain unchanged. Inliant’s proprietary markers enable the cameras to accurately track the handpiece position.
2. Patient Tracker
The patient tracker is attached to the stent and worn by the patient during surgery. The proprietary markers on the patient tracker allow tracking of the patient’s position relative to the handpiece and drill for optimal surgical accuracy.
A stent is fabricated chairside using a fiducial and thermoplastic beads, and is worn by the patient during CBCT. Registration markers located in the fiducial are recognized by Inliant’s software as the anchor point between the CBCT scan and the patient’s anatomy.
3. Stent
Why
Patient Tracker Set
Designed to work anywhere in the mouth while easily maintaining line-of-sight surgical tracking
Doesn’t compromise the clinician’s access to surgery
Smaller patient tracker means comfort for the patient
Attachment–free Handpiece
Minimal impact to workflows as there is nothing attached to the handpiece; ergonomics and tactile feedback are unchanged
Conventional handpiece made by a leading manufacturer
No pre-surgical calibration required
Optimized Cart
Full-length arm achieves surgical tracking in any operatory
Adjustable monitor fits any operatory configuration
Sleek design / space-efficient
Why Use Dynamic Surgical Navigation?
-
Same day planning and surgery
-
One pre-op scan reduces or eliminates the need for x-rays during the implant procedure
-
Ability to change plan, to adapt to clinical situation, during surgery
-
Immediate extraction & placement of single and/or multiple implants in aesthetically challenging zones
-
Improved control of drilling trajectory, enhancing predictability
-
Most beneficial in areas where there is questionable bone volume, limited vertical space, diverging roots or tight interdental spacing
-
Enhances the restorative outcome and the long-term success of implant-supported restorations
-
No outsourcing or laboratory preparation needed, reducing time and cost